background image

Shad-o-Box 1K/2K HS User Manual 

 

p. 5 

 

1.

 

Safety Information 

Installation Warning 

The operators of this equipment are responsible for the safe and prudent installation of the detector in their own 
system. All X-ray sources and controls, shielding, personnel safety monitoring devices, and personnel safety 
precautions involved in the acquisition and display of data are the responsibility of the end user. 

Safety Statement 

The general safety precautions that follow must be observed during all phases of installation, operation, service and 
repair of this system. Failure to comply with these precautions, or with specific warnings noted in this manual, 
violates the safety standards of design, manufacture and the intended used of this system. Teledyne DALSA 
assumes no responsibility for the user’s failure to comply with these requirements. 
 

Warning: This digital camera system, when installed, is subject to exposure from X-rays during operation. 

 
To ensure personnel safety, it is necessary that a radiation meter be used to check for radiation leakage after 
installation of the digital camera in the end users system.  
 
Teledyne DALSA assumes no responsibility for the proper installation of X-ray shielding, X-ray shield enclosure 
testing, or safe and prudent operation of the camera system in the end user's installation. It is the end users 
responsibility to ensure that local and federal guidelines regarding the installation and operation of X-ray sources are 
followed.  
 
For those parties supplying the power requirements to the Shad-o-Box HS, the voltage specifications must be strictly 
adhered to or the system will no longer be considered covered under warranty. 

 

No User Serviceable Components 

There are no components in this system which need to be replaced, modified, or adjusted by the end user. Please 
contact Teledyne DALSA Support for assistance if needed. 
 

Safety Warning:

 Tampering with this product voids the warranty and may degrade the detectors image quality, 

resulting in a possibly unsafe condition. 
 
The system has been designed to minimize the amount of interference it may generate in a typical installation. This 
equipment generates and can radiate radio frequency energy and, if not installed and operated in accordance with the 
instructions, may cause harmful interference to other devices in the area.  

Disposal of Product 

This detector does not contain batteries. Dispose of the unit in accordance with local regulatory guidelines. 
 

Содержание Shad-o-Box 2K HS

Страница 1: ...Teledyne DALSA Shad o Box 1K 2k HS Detector User Manual December 11 2018 www TeledyneDALSA com...

Страница 2: ...it and electronics technology software and highly engineered semiconductor wafer processing Products and services include image sensor components electronic digital cameras X ray detectors vision proc...

Страница 3: ...ody and Front Cover 7 Periodic Maintenance 7 Calibration 7 5 Specifications 8 6 Connectors Cables and Status Indicators 9 7 Setting up the Detector 10 GigE Network Adapter 10 Connect Ethernet cable 10...

Страница 4: ...Shad o Box 1K 2K HS User Manual p 4 Shuttering 17 11 Mechanical Drawings 18 Revision History 20...

Страница 5: ...ALSA assumes no responsibility for the proper installation of X ray shielding X ray shield enclosure testing or safe and prudent operation of the camera system in the end user s installation It is the...

Страница 6: ...ld by Teledyne DALSA as replacement parts may result in increased emission or decreased immunity of the Shad o Box HS Detector Static precautions Observe proper ESD static control procedures when hand...

Страница 7: ...tector body surface Wipe off with a clean soft cloth Do not use any harsh cleansers or solvents that may damage the paint or other finishes on the detector In the event of detector exposure to bio haz...

Страница 8: ...Non linearity 10 90 FS 1 5 Readout period 3 45 ms Output data rate 40 MHz 1 dark current doubles approx every 8 C 2 ADU Analog Digital Unit 1 LSB Least Significant Bit 3 time required to transfer ima...

Страница 9: ...ype FHG 0B 302 CLAD52Z straight type FGG 0B 302 CLAD52 Detector Status LED The detector is equipped with a color LED used to display the status of the detector s operation The table below summarizes t...

Страница 10: ...Intel PRO 1000 MT adapter Review the NIC documentation concerning any special driver required for Windows Install the PCI bus Gigabit NIC as described by the NIC manufacture s documentation Connect Et...

Страница 11: ...on Sapera LT and CamExpert Installation A link to download the software will be emailed to you after submitting the application Complete the download process and run the installation file e g SaperaLT...

Страница 12: ...rger than 9000 bytes For this reason we advise to set the packet size to 9014 bytes jumbo packet enabled Interrupt Moderation Normally each time a packet is received by the network card the associated...

Страница 13: ...conditions the host PC system CPU may be busy with tasks other than the imaging application Incoming image packets remain in the PC memory allocated to store packets instead of immediately being copi...

Страница 14: ...used to manage flow control i e the speed at which stream packet can be output to the network This is useful when connecting multiple detectors to the same port of the network card or when the networ...

Страница 15: ...equests will not be used Connecting 1 After the install is complete plug in the detector communication cable 2 Power up the detector 3 After powering up the detector the application automatically dete...

Страница 16: ...he grabbing process generates multiple frames by operating in a continuous mode To snap an image Click the Snap button The Detector has now snapped a single frame The image appears in the GUI window T...

Страница 17: ...interval is marked with the dark green rectangle Row Pixel Array Time ReadOut Integration Time Frame N Frame N 1 Trigger Input Trigger Output The period of time in between successive frame read outs...

Страница 18: ...Shad o Box 1K 2K HS User Manual p 18 11 Mechanical Drawings Shad o Box 1K HS Model all measurements are in mm...

Страница 19: ...Shad o Box 1K 2K HS User Manual p 19 Shad o Box 2K HS Model all measurements are in mm...

Страница 20: ...ox 1K 2K HS User Manual p 20 Appendix A Revision History Revision Number Change Description Revision Date 01 Draft release May 10 2016 02 New address January 12 2018 03 Added SB2kHS detector December...

Отзывы: