Piranha HN RoHS User Manual
Teledyne DALSA
03-032-20135-00
19
Command
Parameter Range
- = range
: = multiple parameter separator
/ = member of a set separator
NA = command not available in
current operating mode
•
y
= pixel row number
Example:
To return the current camera settings
gcp
<CR>
Camera Help Screen
For quick help, the camera can return all available commands and parameters through the serial
interface.
There are two different help screens available. One lists all of the available commands to configure
camera operation. The other help screen lists all of the commands available for retrieving camera
parameters (these are called “get” commands).
To view the help screen listing all of the camera configuration commands, use the command:
Syntax:
h
To view a help screen listing all of the “get” commands, use the command:
Syntax:
gh
Notes:
For more information on the camera’s “get” commands, refer to
Returning Camera Settings
.
The camera configuration command help screen lists all commands available. Parameter ranges
displayed are the extreme ranges available. Depending on the current camera operating conditions, you
may not be able to obtain these values. If this occurs, values are clipped and the camera returns a warning
message.
Some commands may not be available in your current operating mode. The help screen displays NA in
this case.
Example Help Screen for HN-80-08k40 TDI Mode Operation
OK>h
ccf correction calibrate fpn
ccg calibrate camera gain i 4096-16064
clm camera link mode m 2/3/15/16/21
cpa calibrate PRNU algorithm mi 2/4/:4096-16220
css correction set sample m 1/1024/2048/4096
dpc display pixel coeffs xx 1-8192:1-8192
gcl get command log
gcm get camera model
gcp get camera parameters
gcs get camera serial
gcv get camera version
get get values s
gfc get fpn coeff x 1-8192
gh get help
gl get line xx 1-8192:1-8192
gla get line average xx 1-8192:1-8192
gpc get prnu coeff x 1-8192
Parameters
i = integer
f = floating point number
m = member of a set
s = string
t = tap
x = pixel column number
y = pixel row number