Piranha Color Camera User’s Manual
88
DALSA
03-032-10211-03
9/27/2007
Mnemonic
Syntax
Parameters
Description
non-volatile memory set previously
using the
ssn
command.
write user settings
wus
Write current camera settings to non-
volatile memory set previously using
the
ssn
command.
A5 Error Handling
The following table lists warning and error messages and provides a description and
possible cause. Warning messages are returned when the camera cannot meet the full
value of the request; error messages are returned when the camera is unable to complete
the request.
Table 10: Warning and Error Messages
Message
Description
Warning 01:
Outside of
specification>
Parameter accepted was outside of specified operating range (e.g. gain
greater than ±10 dB of factory setting, or SSF below specification).
Warning 02:
Clipped to min>
Parameter was clipped to the current operating range. Use GCP or
GET to see value used.
Warning 03:
Clipped to max>
Parameter was clipped to the current operating range. Use GCP or
GET to see value used.
Warning 04: Related
parameters
adjusted>
Internal operating condition is adjusted to accommodate the entered
command. E.g. requesting exposure time longer than line time
automatically adjusts the line time to meet the exposure time
requirement.
Warning 07:
Coefficient may be
inaccurate A/D
clipping has
occurred>
In the region of interest (ROI) greater than 6.251% single or 1% of
averaged pixel values were zero or saturated.
Warning 08: Greater
than 1% of
coefficients have
been clipped>
Greater than 1% of FPN or PRNU coefficients have been calculated to
be greater than the maximum allowable and so were clipped.
Warning 09:
Internal line rate
inconsistent with
read out time>
Changes to the parameter (e.g. horizontal averaging) have changed read
out time and that is greater than the
internal
SYNC.
Error Message
Description
Error 01: Internal
error xx>
Where xx is a code list below.
Only output during power up.
Customer should contact Dalsa customer support.
Error 02:
Unrecognized
command>
Command is not valid (or not available at the current access level).
Error 03: Incorrect
number of
parameters>
Too many or too few parameters.
Содержание PC-30-02K80-R
Страница 6: ...Piranha Color Camera User s Manual 6 DALSA 03 032 10211 03 9 27 2007...
Страница 32: ...Piranha Color Camera User s Manual 32 DALSA 03 032 10211 03 9 27 2007 Exposure Modes in Detail...
Страница 74: ...Piranha Color Camera User s Manual 74 DALSA 03 032 10211 03 9 27 2007...
Страница 90: ...Piranha Color Camera User s Manual 90 DALSA 03 032 10211 03 9 27 2007...
Страница 92: ...Piranha Color Camera User s Manual 92 DALSA 03 032 10211 03 9 27 2007...
Страница 94: ...Piranha Color Camera User s Manual 94 DALSA 03 032 10211 03 9 27 2007...
Страница 96: ...Piranha Color Camera User s Manual 96 DALSA 03 032 10211 03 9 27 2007...