56
Appendix A: GenICam Commands
Display Name
Feature
Description
Device
Version
& View
Save Calibration
flatfieldCalibrationSave
Saves the User PRNU set
specified by
flatfieldCorrectionCurrentActiveSet
to the camera.
1.00
Guru
DFNC
Load Calibration
flatfieldCalibrationLoad
Loads the User PRNU set
specified by
flatfieldCorrectionCurrentActiveSet
to the camera and makes it active.
1.00
Guru
DFNC
Output LUT Mode
lutMode
Allows the output LUT to be
selected
1.00
Beginner
DFNC
Off
Off
The output LUT is disabled and
linear data is output
Gamma Correction
Gamma Correction
Gamma correction table is used
User Defined
User Defined
LUT download by the user is
used.
Gamma Correction
gammaCorrection
Sets the output LUT gamma
correction factor
𝐷𝑁
𝑜𝑢𝑡
= 255 ×
(
𝐷𝑁
𝑖𝑛
255
)
1
𝛾
1.00
Beginner
DFNC
Image Filter Mode
imageFilterMode
Enable image filter.
Image Filter Type
imageFilterType
Read-only: Weighted Average
Image Filter Kernel Size
imageFilterKernelType
Kernel 1x3 or 1x5
Image Filter Contrast Ratio
imageFilterContrastRatio
0 to 1
Image Format Control Category
The camera’s Image Format controls, as shown by CamExpert, group parameters used to configure
camera pixel format, image cropping, binning and test pattern generation features.
Содержание Linea HS Series
Страница 5: ...The Linea HS Monochrome Cameras 5 DECLARATION OF CONFORMITY 73 DOCUMENT REVISION HISTORY 74...
Страница 13: ...The Linea HS Monochrome Cameras 13 Responsivity QE Plots Note values measured using 8 bit 1x gain main array...
Страница 14: ...14 The Linea HS Monochrome Cameras Mechanical Drawings Figure 3 HL FM 08K30H 00 R Mechanical Drawing...
Страница 15: ...The Linea HS Monochrome Cameras 15 Figure 4 HL HM 16K30H 00 R Mechanical Drawing...
Страница 26: ...26 Camera Performance and Features Figure 7 Image with incorrect scan direction...
Страница 73: ...Declaration of Conformity 73 Declaration of Conformity...