36
Operational Reference
Genie HM-HC Series-GigE Vision Camera
XML features for Power-up Configuration:
UserSetSelector
= Selects the feature User Set to configure {Factory = 0, UserSet1 = 1}
UserSetLoad
= Loads the User Set specified by UserSetSelector to the camera and makes it
active
UserSetSave
= Saves the User Set specified by UserSetSelector to the camera
UserSetDefaultSelector
= Selects the feature User Set to load at camera reset
Camera Information via Sapera LT or GigE Vision Compliant
Applications
Sapera
Genie Sapera parameters for Camera and Sensor Information:
Interface
= {GigE Vision}
DeviceVendorName
= “DALSA”
DeviceModelName
= “Genie HM1400” for Genie HM1400
DeviceVersion
= String representing the version of the camera
FirmwareVersion
= String representing the version of the camera firmware
DeviceID
= String representing the camera serial number
MACAddress
= String representing the camera MAC address
DeviceUserID
= String representing the user-define name for the camera
DeviceMaxThroughput
= Maximum throughput of image streaming in bytes/sec.
DeviceScanType
= {Areascan}
ColorType
= Monochrome Sensor
SensorWidth
= Width of the sensor in pixels
SensorHeight
= Height of the sensor in lines
PixelSize
= Number of bits per pixel
In CamExpert, these parameters are visible under “Camera Information” and “Sensor” tabs.
See
"
Accessing Features with + LT
" on page 76
.
hidden table separator
XML features for Camera and Sensor Information:
DeviceVendorName
= Name of camera vendor
DeviceModelName
= Name of the camera model
DeviceVersion
= Displays the device version which includes the firmware release and build.
DeviceFirmwareVersion
= Displays the currently loaded firmware version manufacturer's
code.
DeviceID
= Displays the factory set camera serial number.
DeviceUserID
= A user set ID of up to 15 characters. By default this field is set to the serial
number of the camera.
DeviceScanType
= {Areascan}
DeviceMaxThroughput
= Maximum number of bytes per second the device supports
DeviceRegistersStreamingStart
= Announces the start of registers streaming without
immediate checking for consistency
DeviceRegistersStreamingEnd
= Announces the end of registers streaming and performs
validation for registers consistency before activating them
DeviceRegistersCheck
= Performs an explicit register set validation for consistency
DeviceRegistersValid
= States if the current register set is valid and consistent
SensorWidth
= Width of sensor (effective pixels)
SensorHeight
= Height of sensor (effective pixels)
PixelSize
= Number of bits per pixel (typically 8 or 10-bits per pixel)
WidthMax
= Maximum image width. Depends on binning and ROI settings
HeightMax
= Maximum image height. Depends on binning and ROI settings
Содержание Genie HM640
Страница 8: ...6 Contents Genie HM HC Series GigE Vision Camera...
Страница 34: ...32 Installing the Genie Camera Genie HM HC Series GigE Vision Camera...
Страница 94: ...92 Operational Reference Genie HM HC Series GigE Vision Camera...
Страница 98: ...96 Network Overview Tools Genie HM HC Series GigE Vision Camera...
Страница 104: ...102 Sapera CamExpert Guide Genie HM HC Series GigE Vision Camera...
Страница 107: ...Genie HM HC Series GigE Vision Camera Technical Specifications 105 Genie 3D View with Right angle C mount and CS mount...
Страница 126: ...124 Technical Specifications Genie HM HC Series GigE Vision Camera EC FCC Declaration of Conformity...
Страница 138: ...136 Glossary of Terms Genie HM HC Series GigE Vision Camera...