58
•
Appendix A: GenICam Commands
Flat Field Category
The Flat Field controls, as shown by CamExpert, group parameters used to control the FPN and
PRNU calibration process.
Figure 23
:
Flat Field Panel
Flat Field Control Feature Description
Display Name
Feature
Description
View
Mode
flatfieldCorrectionMode
Beginner
DFNC
Off
Off
FPN and PRNU correction disabled.
On
On
FPN and PRNU correction enabled.
Clear Coefficents
flatfieldCalibrationClearCoefficient
Reset all FPN to 0 and all PRNU
coefficients to 1.
Beginner
DFNC
Calibration Algorithm
flatfieldCorrectionAlgorithm
Selection between four different
PRNU algorithms.
Beginner
DFNC
Peak
Peak Calculation of PRNU coefficients to
bring all pixels to the peak.
Peak, Image Filtered
PeakFilter A low pass filter is applied to the
average line values before calculating
the coefficients. Use this algorithm if
the calibration target is not uniformly
white or if it is not possible to defocus
the image. Because of the low pass
filter, this algorithm is not able to
correct pixel-to-pixel variations and
so it is preferable to use the “Peak”
algorithm.
Set Target
Target Calculation of PRNU coefficients to
bring all pixels to the target value.