Piranha ES-Sx User Manual
03-032-20162-00
Teledyne DALSA
34
adjust gain.
Example:
cpa 5 13000
Setting a Pixel’s PRNU Coefficient
Purpose:
Sets an individual pixel’s PRNU coefficient.
Syntax:
spc i i
Syntax Elements:
i
The pixel number from 1 to sensor pixel count.
i
Coefficient value in a range from 0 to 28671 where:
Returning FPN and PRNU Coefficients
Purpose:
Returns all the current pixel coefficients in the order FPN, PRNU,
FPN, PRNU… for the range specified by
x1
and
x2
. The camera
also returns the pixel number with every fifth coefficient.
Syntax:
dpc x1 x2
Syntax Elements:
x1
Start pixel to display in a range from 1 to (sensor pixel count-1).
x2
End pixel to display in a range from
x1
+1 to sensor pixel count.
Notes:
•
If
x2
<
x1
then
x2
is forced to be
x1
.
Example:
dpc 10 20
Enabling and Disabling Pixel Coefficients
Purpose:
Enables and disables FPN and PRNU coefficients.
Syntax:
epc i i
Syntax Elements:
i
FPN coefficients.
0
= FPN coefficients disabled
1
= FPN coefficients enabled
i
PRNU coefficients.
0
= PRNU coefficients disabled
1
= PRNU coefficients enabled
Example:
epc 0 1
PRNU coefficient =
i
4096
1 +