dallmeier SMAVIA appliance VideoNetBox II Скачать руководство пользователя страница 8

Connections

Voltage supply

12 V DC ±5%

Power consumption

Max. 80 W*

)

Thermal output

Max. 273 BTU/h

Temperature

+ 5°C up to +40°C (41°F − 104°F) (+20°C up to +25°C (68°F − 77°F) recommended)

The following illustrati on shows hardware with opti onal components (full range of equipment).

A

Power Supply 12 V DC

ODU socket, 2-pole, 12 V DC ±5%

N

Not Active

3.5 mm phone jack

 

(optional, only with Analog Upgrade Kit)

B

12 V DC OUT

Weidmüller socket, 2 pins, 12 V DC ± 5% (max. 3

.

2 A)

O

Not Active

3.5 mm phone jack

 

(optional, only with Analog Upgrade Kit)

C

Fuse for 12 V DC OUT

5 × 20 mm, type F, 3.15 A

P

USB Interface

4

×

 USB 2.0, type A

D

Serial Interface COM 1

D-SUB, 9 pins, 1

×

 RS23

2

Q

Serial Interface COM 2

2 pins on Weidmüller 20 pins, 1

×

 RS485 Half Duplex 

(for Dallmeier PTZ dome)

E

Video OUT Mini-D-SUB

Mini-D-SUB, 15-pole, 1920 × 1080 

(for configuration, LocalViewing optional)

R

Relay OUT (1 and 2)

Weidmüller socket, 4 pins, max. 12 V DC / 24 V AC / 0.5 A, 

150 mOhm

F

Audio OUT

3.5 mm phone jack, 1 kOhm, 2.828 V

pp

 

(optional, for intercom)

S

Contact IN global (1 - 4)

Weidmüller socket, 4 pins, only for switch / push button 

(dry contact)

G

AUX / Line IN

3.5 mm phone jack, 16 kOhm, 2.828 V

pp

 

(optional, for intercom)

T

Contact IN cameras (1 - 8)

Weidmüller socket, 8 pins, only for switch / push button 

(dry contact)

H

Video OUT HDMI

HDMI 1.3, type A, 1920 

×

 1080 

(for configuration, LocalViewing optional)

U

Audio IN (1 - 8)

D-SUB, 15-pole, 1 kOhm, 2.828 V

pp

, D-SUB / Cinch adapter

(optional, only with Analog Upgrade Kit)

I

Video OUT BNC 1

BNC/CVBS, 75 Ohm, 1 V

pp 

(optional, only with Analog Upgrade Kit)

V

Status LED (Power)

Blue / The device is in operation.

J

Video OUT BNC 2

BNC/CVBS, 75 Ohm, 1 V

pp 

(optional, only with Analog Upgrade Kit)

W

Status LED (Record)

Green / The device is recording.

K

Ethernet Interface 2

RJ45, 10/100/1000 Mbps

(optional, for ViProxy)

X

Status LED (Alarm)

Orange / The device is in alarm mode.

L

Ethernet Interface 1

RJ45, 10/100/1000 Mbps 

Y

Status LED (Error)

Red / The device indicates an error.

M

Video IN (1 - 8)

D-SUB, 15-pole, 1 kOhm, 2.828 V

pp 

(optional, for D-SUB / BNC adapter cable)

A   B   C             D       E          F  G H      I   J    K  L    M  N O  P Q  R   S      T       U V W X Y

*

)

 The PSU must be able to supply at least 120 W, if the 12 V DC OUT socket is in use.

8

 www.dallmeier.com

 

Содержание SMAVIA appliance VideoNetBox II

Страница 1: ...PRELOADED English Commissioning 004707 Rev 1 0 2 2014 03 13 Appliance VideoNetBox II...

Страница 2: ...d result in minor or moderate injury Notice NOTICE indicates practices for preventing property damage incorrect configurations or faulty operations Intended use The VideoNetBox II is a compact applian...

Страница 3: ...hours until the device has reached room temperature before commissioning Earthing Equipotential Bonding For the safety of persons protection against dangerous contact voltages and devices protection a...

Страница 4: ...n a computer room as defined in the US fire protection regulation Standard for Protection of Electronic Computer Data Processing Equipment ANSI NFPA 75 Secured room Risk of manipulation and sabotage A...

Страница 5: ...nnect the HDD 1 to the designated connection cable Insert the HDD 1 completely into the guidances of the HDD slot 1 Proceed as described in order to mount the HDD 2 if necessary Finally put the cover...

Страница 6: ...h 4 screws Connect the appliance as described on the following pages Commission the appliance as described on the following pages Ensure a stable mounting surface Ensure a horizontal or vertical mount...

Страница 7: ...3 6 5 9 without feet 280 100 150 mm 11 0 3 9 5 9 with feet 150 mm 5 9 230 mm 9 0 95 mm 3 6 280 mm 11 0 256 mm 10 1 100 mm 3 9 4 mm 0 2 Dimensions www dallmeier com 7 HDD Mounting Safety Requirements L...

Страница 8: ...r intercom S Contact IN global 1 4 Weidm ller socket 4 pins only for switch push button dry contact G AUX Line IN 3 5 mm phone jack 16 kOhm 2 828 Vpp optional for intercom T Contact IN cameras 1 8 Wei...

Страница 9: ...recording 5 Contact 3 Camera 3 Start recording 6 Contact 4 Camera 4 Start recording 7 Contact 5 Camera 5 Start recording 8 Contact 6 Camera 6 Start recording 9 Contact 7 Camera 7 Start recording 10 Co...

Страница 10: ...er the start is complete Login In the initial state it is possible to login without a password The rights of the Administrator group are valid Note that the definition of the passwords and of the netw...

Страница 11: ...or group are valid Note that the definition of the passwords and of the network parameters is necessary for remote access SMAVIA Viewing Client Observe the documentation Operation for the software PSe...

Страница 12: ...e event of the grant of a patent utility model or design We reserve the right to make technical modifications The manufacturer accepts no liability for damage to property or pecuniary damages arising...

Отзывы: