Outdoor Mounting Accessories – Junction Box DJB-115W
22
www.dallmeier.com
6 Connections
The connection and commissioning of the unit may only be carried out by qualified per
-
sonnel.
DANGeR
electric shock hazard
Danger of death or serious injury
Disconnect the power supply unit from the mains socket before con-
necting or disconnecting the device or ensure that the AC mains power
outside the device is switched OFF.
6.1
Power Connections
115
230
115
AC OUTPUT
OUT 1
OUT 2
OUT 3
AC INPUT
115V/230V
SWITCH
PoE
PoE+2
PoE+1
RX−
PoE−2
PoE−1
RX+
TX+
TX−
VIDEO GN
D
VIDE
O
PoE
ALARM
A
ALARM
B
AL1
AL2
AL3
AL4
GND
NC1
NO1
COM
AL5
AL6
AL7
AL8
GND
NC2
NO2
COM
AL1
AL2
AL3
AL4
GND
NC1
NO1
COM
AL5
AL6
AL7
AL8
GND
NC2
NO2
COM
ALARM
A
ALARM
B
RX−
RX+
TX
+
TX
−
RS485
RS485
RX−
RX+
TX+
TX−
Line IN
Line OUT
AUDI
O
OUT R
OUT L
OUT GND
IN R
IN L
IN GND
Fig. 6-1: Power connections
First, set the correct AC mains power voltage suitable for your country (115 V or 230 V)
before connecting the AC mains power to the AC input terminal.
Next, connect the protective earthing conductor to the AC input terminal labelled with
“PE” (protective earth).
Then, connect the AC live wire (phase conductor) to the AC input terminal labelled
with “L” (live wire) and the AC neutral wire (return conductor) to the AC input terminal
labelled with “N” (neutral wire).
Finally, connect the camera and/or other equipment (e.g. heater of weather-proof hous-
ing) to the AC output terminal.
Содержание Domera DJB-115W
Страница 1: ...Outdoor Mounting Accessories Rev 2 0 0 003845 2012 03 15 English Installation Junction Box DJB 115W...
Страница 30: ...Outdoor Mounting Accessories Junction Box DJB 115W 30 www dallmeier com For Your Notes...
Страница 31: ...Outdoor Mounting Accessories Junction Box DJB 115W www dallmeier com 31 For Your Notes...