dallmeier DF4 20HD-DN/IR Series Скачать руководство пользователя страница 9

www.dallmeier.com 

9

DF4(X)20HD-DN/IR 

General Notes

3  General Notes

Scope of Delivery

The standard scope of delivery includes all brackets, screws and plastic screw 

anchors that are necessary for a proper installation.

However, it has to be considered that the scope of delivery may differ depend-

ing on the ordered equipment, the device variant or the country of destination.

Transportation and Packaging

Store the original packaging for transportation at a later date. Dallmeier is not 

responsible for any damage resulting from unprofessional/improper transporta-

tion. The goods should only be shipped in their original packaging.

If the original packaging is no longer available, ensure that the packaging used 

sufficiently protects the unit against damage, moisture, heat and cold.

Warranty

The terms and conditions valid at the time the contract was signed shall apply.

Approvals/Certifications

The following approvals/certifications were valid at the time of this document’s 

compilation:

CE, FCC, ACA, DGUV Test, UL, DIN EN 50130-4 compliant

Visit www.dallmeier.com for possible updates.

Note (USA)

This equipment has been tested and found to comply with the limits for a Class A digital device, 

pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protec-

tion against harmful interference when the equipment is operated in a commercial environment. 

This equipment generates, uses, and can radiate radio frequency energy and, if not installed 

and used in accordance with the instruction manual, may cause harmful interference to radio 

communications. Operation of this equipment in a residential area is likely to cause harmful in-

terference in which case the user will be required to correct the interference at his own expense.

Содержание DF4 20HD-DN/IR Series

Страница 1: ...005517 1 0 4 2017 03 15 DF4 X 20HD DN IR Commissioning English...

Страница 2: ...All trademarks identified by are trademarks or registered trademarks of the following owners Adobe and Flash of Adobe Systems Incorporated headquartered in San Jos California USA AMD and AMD Athlon of...

Страница 3: ...General Notes 9 Scope of Delivery 9 Transportation and Packaging 9 Warranty 9 Approvals Certifications 9 Appropriate Use 10 Main Performance Features 11 4 Requirements 12 General 12 Voltage Supply 12...

Страница 4: ...l unit About this Document This document contains the most important steps for the connection commis sioning and configuration of the unit Safety instructions general notes and basic technical specifi...

Страница 5: ...could result in minor or moderate injury NOTICE NOTICE indicates practices for preventing property damage incorrect configurations or faulty operations For reasons of clarity and readability various...

Страница 6: ...rding data worker and environmental protection before using the unit and ensure compli ance with them System Components Only use internal components that have been tested and approved by Dallmeier Ina...

Страница 7: ...ded when the unit has been unused for a long period of time Operating Conditions Unfavourable operating conditions may shorten the life of the unit and may cause malfunctions damages and data loss and...

Страница 8: ...ielding or eye protection When looking directly into the switched on IR LEDs in a dark environment en sure a minimum safety distance of 1 metre and short exposure times in order to avoid eye damage Di...

Страница 9: ...cold Warranty The terms and conditions valid at the time the contract was signed shall apply Approvals Certifications The following approvals certifications were valid at the time of this document s c...

Страница 10: ...ure and motor driven P Iris megapixel varifocal lens which allows for the convenient adjustment configuration of the focal length zoom focus and iris aperture via the web browser The novel P Iris cont...

Страница 11: ...justment P Iris control Video compression H 264 MJPEG Frame rate up to 30fps Simultaneous Dual or Tri Streaming Automatic White Balance ATW One Push AWB Manual White Balance MWB Automatic Gain Control...

Страница 12: ...irt with steam or oil vapours e g kitchen with direct sunlight with strong heat emissions e g radiator with improper ambient temperatures near sources with strong radiation e g radio transmitters magn...

Страница 13: ...notes NOTICE Damage to the surface of the device Clean the weather proof housing outside with a soft dry and anti static cloth Do not use detergents Clean the acrylic front glass of the weather proof...

Страница 14: ...14 www dallmeier com Part Description DF4 X 20HD DN IR 5 Part Description Fig 1 2 axis pan tilt head Wall mount bracket with internal cable routing RJ45 plug Power Ethernet...

Страница 15: ...www dallmeier com 15 DF4 X 20HD DN IR Part Description Fig 2 Lens 3 semi covert 850nm high power LED for homogeneous IR illumination Ambient light sensor Integrated microphone...

Страница 16: ...t may only be carried out by qualified personnel Step 1 Fig 3 Hexagon socket screw M8 12mm pan Hexagon socket screw M8 12mm tilt Run the Ethernet cable of the camera through the wall mount bracket Ass...

Страница 17: ...maximum adequate carrying capacity of the supporting structure Use screws suitable for the wall material Use the correct type of anchor for your wall type Plastic screw anchors for solid wall material...

Страница 18: ...n each hexagon socket screw before making any alignments and tighten it again when finished see Fig 3 You can also align the image section at a later point in time using the Digital Image Shift functi...

Страница 19: ...S Microsoft Windows XP Windows Vista Windows 7 each with latest service pack Processor CPU 3GHz Intel Pentium 4 AMD Athlon 64 3400 or faster or equivalent Random access memory RAM 1GB Windows XP 2GB W...

Страница 20: ...be automatically downloaded via Internet after the connection to the device is established only with Microsoft Internet Explorer and if it is not already installed the configuration without live vide...

Страница 21: ...word as soon as possible Click CONFIG in the user interface of the live mode The login dialogue is displayed Enter the Username Default admin if required Enter the Password Confirm with OK The graphic...

Страница 22: ...ne Integrated Connections Power Ethernet 1 RJ45 plug 10BASE T 100BASE TX PoE Electrical Data Voltage supply Power over Ethernet PoE Class 0 PoE standard IEEE 802 3af Power consumption Max 12 95W Mecha...

Страница 23: ...www dallmeier com 23 DF4 X 20HD DN IR Technical Specifications Dimensions 362 mm 14 27 229 mm 9 04 88 mm 3 48 226 mm 8 91 138 mm 5 44 233 mm 9 19 71 mm 2 81 99 mm 3 89...

Страница 24: ......

Отзывы: