8 Installation and Commissioning
The installation and commissioning of the device may only be carried out by quali-
fied personnel.
The following tools/accessories are required for the installation of the device:
•
Drywall utility saw or jigsaw
•
M6 eye bolt
•
Torx screwdriver with hollow point (T20 H) or equivalent tool for
tamper-resistant 6-lobe security screw with pin (Torx-TR 20)
•
Ceiling hook, safety cable (steel wire rope with two loops) and carabiner
•
Phillips
*)
screwdriver (PH1)
•
Optional: PG16 cable gland or rubber cable grommet
WARNING
Personal injury caused by falling device or collapsing ceiling
Risk of death or serious injury to the head
➡
Observe the manufacturer’s instructions regarding the maxi-
mum permissible carrying capacity of the supporting structure
and the suspended ceiling or ceiling panel.
➡
For fixing the ceiling hook, use an anchor that is suitable for the
ceiling type and construction material, such as for example:
•
Plastic screw anchor for use in solid masonry materials
(concrete/brick)
•
Gravity or spring toggle anchor for use in drywall ceilings
(plasterboard)