manualshive.com logo in svg
background image

006202 / 2.0.0 / 2017-03-15

IM

DDF4820HDV-DN

Commissioning

English

Содержание DDF4820HDV-DN-IM

Страница 1: ...006202 2 0 0 2017 03 15 IM DDF4820HDV DN Commissioning English...

Страница 2: ...ks or registered trademarks of the following owners Adobe and Flash of Adobe Systems Incorporated headquartered in San Jos California USA AMD and AMD Athlon of Advanced Micro Devices Inc headquartered...

Страница 3: ...5 4 Safety Instructions 7 5 General Notes 10 Scope of Delivery 10 Transportation and Packaging 10 Warranty 10 Approvals Certifications 11 Appropriate Use 11 6 Requirements 12 General 12 Operation 12 7...

Страница 4: ...ifications and features of the device The target audience is trained system integrators Commissioning The document Commissioning this document contains detailed descriptions on installation connection...

Страница 5: ...NGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious i...

Страница 6: ...uctions are indicated by arrows Carry out instructions one after the other in the sequence described Expressions in bold italics generally indicate a control element on the device switches or labels o...

Страница 7: ...appliances must be followed Regulations The use of video and audio surveillance systems is in general strictly regu lated Inform yourself about the currently valid laws and regulations regarding data...

Страница 8: ...reached room tempera ture before commissioning Earthing Equipotential Bonding For the safety of persons protection against dangerous contact voltages and devices protection against over voltages as w...

Страница 9: ...from the power supply pull out the power plug Contact the sales partner responsible for your area Burnt Smell If you notice burnt smell or a formation of smoke coming from the device im mediately dis...

Страница 10: ...the device depends on the ordered equipment or device variant and may differ from this document s content Certain functions and features may require the purchase of an additional license Transportatio...

Страница 11: ...installed and used in accordance with the instruction manual may cause harmful interference to radio communications Operation of this equipment in a residential area is likely to cause harmful interfe...

Страница 12: ...with improper ambient temperatures near sources with strong radiation e g radio transmitters magnetic fields with corrosive surroundings e g gases salt water with insufficient air ventilation e g clo...

Страница 13: ...o signal transformer balun for galvanic ground isolation between the signal source camera and the RG 59 cable If the device or the cables connected to the device are located near sources with strong r...

Страница 14: ...ve the following notes NOTICE Damage to the surface of the device Clean the housing outside with a soft dry and antistatic cloth Do not use detergents Clean the plastic bubble with water and some dish...

Страница 15: ...quate carrying capacity of the supporting structure and the suspended ceiling or ceiling panel Use screws suitable for the ceiling wall material Use the correct type of anchor for your ceiling wall ty...

Страница 16: ...e not to use both power sources simultaneously In order to comply with UL s requirements always use a UL certified Limited Power Source LPS Class 2 power supply unit when operating the device with a s...

Страница 17: ...www dallmeier com 17 Commissioning DDF4820HDV DN IM Torx screwdriver T20 H...

Страница 18: ...18 www dallmeier com DDF4820HDV DN IM Commissioning Loosen the three tamper resistant torx screws Torx TR 20 of the cover ring with a torx screwdriver T20 H 3 Tamper resistant torx screw Torx TR 20...

Страница 19: ...www dallmeier com 19 Commissioning DDF4820HDV DN IM Remove the cover ring bubble...

Страница 20: ...20 www dallmeier com DDF4820HDV DN IM Commissioning Screw the M6 eye bolt onto the bottom side of the housing M6 eye bolt Ceiling clamp 2...

Страница 21: ...www dallmeier com 21 Commissioning DDF4820HDV DN IM Cut a circular hole 143mm into the suspended ceiling or ceiling panel Screw a ceiling hook into the supporting structure 143mm Ceiling hook...

Страница 22: ...22 www dallmeier com DDF4820HDV DN IM Commissioning Insert the housing into the circular cut out Basic position of ceiling clamp...

Страница 23: ...www dallmeier com 23 Commissioning DDF4820HDV DN IM Attach a safety wire to the M6 eye bolt use a carabiner and the ceiling hook Carabiner Safety wire...

Страница 24: ...24 www dallmeier com DDF4820HDV DN IM Commissioning M4 locking screw ceiling clamp Phillips screwdriver...

Страница 25: ...www dallmeier com 25 Commissioning DDF4820HDV DN IM Tighten the M4 locking screw of both ceiling clamps with a Phillips screw driver until the housing is securely fixed Locked ceiling clamp 2...

Страница 26: ...w dallmeier com DDF4820HDV DN IM Commissioning Run the required cables through a PG16 cable gland and screw the PG16 cable gland in the appropriate thread on the bottom side of the housing PG16 cable...

Страница 27: ...www dallmeier com 27 Commissioning DDF4820HDV DN IM...

Страница 28: ...28 www dallmeier com DDF4820HDV DN IM Commissioning Connect the required cables to the connectors of the camera module...

Страница 29: ...tailed descriptions of the possible LAN LED states read the documentation on camera configuration Analog video preview output BNC CVBS 1 0Vp p 75ohm Reserved port not used LAN LED Audio OUT Microphone...

Страница 30: ...30 www dallmeier com DDF4820HDV DN IM Commissioning SD SDHC card optional Min 1GB recommended Max 32GB supported...

Страница 31: ...www dallmeier com 31 Commissioning DDF4820HDV DN IM Rotation 180 Tilt 90 Pan 90 Knurled locking screw Rotation 2...

Страница 32: ...32 www dallmeier com DDF4820HDV DN IM Commissioning...

Страница 33: ...is equipped with a motor driven varifocal lens The focal length zoom and the focus are adjusted over the network in the WebConfig user interface of the camera more information can be found in the docu...

Страница 34: ...4 www dallmeier com DDF4820HDV DN IM Commissioning Attach the cover ring to the housing while ensuring that the ambient light sensor is not covered by the black inner dome cover Black inner dome cover...

Страница 35: ...www dallmeier com 35 Commissioning DDF4820HDV DN IM Tighten the three tamper resistant torx screws Torx TR 20 of the cover ring with a torx screwdriver T20 H...

Страница 36: ...p Signal Not used Ring Not used Signal Sleeve Ground Ground NOTICE For a clean interference free audio signal transmis sion the Audio IN OUT Y Cable Connector FGA 30 is required optionally available A...

Страница 37: ...ller male connector SL 3 50 02 90G mating connector Weidm ller BL 3 50 02 180 SN In order to comply with UL s requirements always use a UL certified Limited Power Source LPS Class 2 power supply unit...

Страница 38: ...e is powered via Power over Ethernet a PoE injector is additionally required Minimum System Requirements Operating system OS Microsoft Windows XP Windows Vista Windows 7 each with latest service pack...

Страница 39: ...d and the Dallmeier Live Video ActiveX are not required for the configuration without live video display or live audio output the latest Dallmeier Live Video ActiveX can be directly downloaded from th...

Страница 40: ...168 2 28 Ensure that the PC web browser can establish a connection to the device via Ethernet Start the web browser Enter the IP address of the device into the address bar of the web browser Confirm t...

Страница 41: ...E Risk of misuse by unauthorized users Change the factory default admin password as soon as possible Click CONFIG in the user interface of the live mode The login dialog is displayed Enter the Usernam...

Страница 42: ...al length and the image section Audio OUT Microphone IN 1 3 5mm phone jack mono signal for stereo plug Mic IN max 63mV RMS input resistance 10kOhm internal gain 20dB Ethernet 1 RJ45 10BASE T 100BASE T...

Страница 43: ...joules Dimensions Approx 170 H 135mm 6 7 H 5 3 Weight Approx 1200g 2 6lb Operating temperature 20 C to 40 C 4 F to 104 F Indoor Relative humidity 0 90 RH non condensing Approvals certifications CE FCC...

Страница 44: ...44 www dallmeier com DDF4820HDV DN IM Commissioning 134 70 mm 5 30 142mm 5 59 114 60mm 4 51 170mm 6 69 60mm 2 36 14mm 0 55 62mm 2 44 28 80mm 1 13 41 50 mm 1 63 12 Dimensions...

Страница 45: ......

Страница 46: ......

Страница 47: ......

Страница 48: ...Dallmeier electronic GmbH Co KG Bahnhofstr 16 93047 Regensburg Germany Phone 49 941 8700 0 Fax 49 941 8700 180 www dallmeier com info dallmeier com...

Отзывы: