www.dallmeier.com
19
Commissioning DDF4520HDV-DN-SM
NOTICE
Damage to the device resulting from improper power
supply
The device can be powered via Power over Ethernet
(PoE, Class 0, IEEE 802.3af) or supplied with a separate
12 V DC power supply unit.
However, always beware not to use both power
sources simultaneously.
In order to comply with UL’s requirements, always
use a UL-certified, Limited Power Source (LPS) Class 2
power supply unit when operating the device with a
separate 12 V DC power supply unit.
You need:
• Torx screwdriver (T20)
• Marking tool (e.g. awl)
• Electric drill
• 3× dowels
• 3× mounting screws (Ø 4 mm)
• Screwdriver (for mounting screws)
• PG16 cable gland
Содержание DDF4520HDV-DN
Страница 1: ...004729 1 0 1 2014 05 05 SM DDF4520HDV DN Commissioning English...
Страница 20: ...20 www dallmeier com DDF4520HDV DN SM Commissioning Torx screwdriver T20...
Страница 21: ...www dallmeier com 21 Commissioning DDF4520HDV DN SM Loosen the torx screws of the housing T20 torx screw 3...
Страница 22: ...22 www dallmeier com DDF4520HDV DN SM Commissioning Remove the housing bubble...
Страница 25: ...www dallmeier com 25 Commissioning DDF4520HDV DN SM Connection board...
Страница 31: ...www dallmeier com 31 Commissioning DDF4520HDV DN SM Drill hole 3 Dowel anchor 3 O ring 3 Mounting screw 3...
Страница 46: ......
Страница 47: ......