background image

004729 / 1.0.1 / 2014-05-05

SM

DDF4520HDV-DN

Commissioning

English

Содержание DDF4520HDV-DN

Страница 1: ...004729 1 0 1 2014 05 05 SM DDF4520HDV DN Commissioning English...

Страница 2: ...rademarks identified by are trademarks or registered trademarks of the following owners Adobe and Flash of Adobe Systems Incorporated headquartered in San Jos California USA AMD and AMD Athlon of Adva...

Страница 3: ...phical Conventions 5 4 Safety Instructions 7 5 General Notes 10 Scope of Delivery 10 Transportation and Packaging 11 Warranty 11 Approvals Certifications 11 Appropriate Use 12 6 Requirements 14 Genera...

Страница 4: ...ications and features of the device The target audience is trained system integrators Commissioning The document Commissioning this document contains detailed descriptions on installation connection a...

Страница 5: ...NGER indicates a hazardous situation which if not avoided will result in death or serious injury WARNING WARNING indicates a hazardous situation which if not avoided could result in death or serious i...

Страница 6: ...uctions are indicated by arrows Carry out instructions one after the other in the sequence described Expressions in bold italics generally indicate a control element on the device switches or labels o...

Страница 7: ...appliances must be followed Regulations The use of video and audio surveillance systems is in general strictly regu lated Inform yourself about the currently valid laws and regulations regarding data...

Страница 8: ...ce has reached room tempera ture before commissioning Earthing Equipotential Bonding For the safety of persons protection against dangerous contact voltages and devices protection against over voltage...

Страница 9: ...from the power supply pull out the power plug Contact the sales partner responsible for your area Burnt Smell If you notice burnt smell or a formation of smoke coming from the device im mediately dis...

Страница 10: ...ss Video OUT Power IN Ethernet for outdoor installations 1 PG16 cable gland 1 Drilling template published in print and on DVD ROM In addition all screws and dowels necessary for a proper installation...

Страница 11: ...l packaging If the original packaging is no longer available ensure that the used packaging suf ficiently protects the device against damage moisture heat and cold Warranty The terms and conditions va...

Страница 12: ...and walls and can be powered via PoE Power over Ethernet Class 0 IEEE 802 3af or supplied with 12V DC separate power supply unit required NOTICE The DDF4520HDV DN SM is designed for indoor installatio...

Страница 13: ...e delivered cable harness Video OUT Power IN Ethernet and the PG16 cable gland instead Protect the device from direct influence of weather conditions rainfall direct sunlight etc Always use a protecte...

Страница 14: ...or with improper ambient temperatures near sources with strong radiation e g radio transmitters magnetic fields with corrosive surroundings e g gases salt water with insufficient air ventilation e g c...

Страница 15: ...gnal transformer balun for galvanic ground isolation between the signal source camera and the RG 59 cable If the device or the cables connected to the device are located near sources with strong radia...

Страница 16: ...ng notes NOTICE Damage to the surface of the device Clean the housing outside with a soft dry and antistatic cloth Do not use detergents If necessary remove dust from the lens element with a suitable...

Страница 17: ...ubble Clean the plastic bubble with water and some dishwashing agent using a soft non linting cloth or sponge Do not rub the plastic bubble with a dry cloth Do not use common glass cleaners Avoid exce...

Страница 18: ...about the maximum adequate carrying capacity of the sup porting structure Use screws suitable for the ceiling wall material Use the correct type of anchor for your ceiling wall type Plastic screw anch...

Страница 19: ...V DC power supply unit However always beware not to use both power sources simultaneously In order to comply with UL s requirements always use a UL certified Limited Power Source LPS Class 2 power sup...

Страница 20: ...20 www dallmeier com DDF4520HDV DN SM Commissioning Torx screwdriver T20...

Страница 21: ...www dallmeier com 21 Commissioning DDF4520HDV DN SM Loosen the torx screws of the housing T20 torx screw 3...

Страница 22: ...22 www dallmeier com DDF4520HDV DN SM Commissioning Remove the housing bubble...

Страница 23: ...www dallmeier com 23 Commissioning DDF4520HDV DN SM Remove the threaded blanking plug of the side cable entry use a screw driver Threaded blanking plug O ring...

Страница 24: ...520HDV DN SM Commissioning Always use the threaded blanking plug and O ring to securely seal the unused cable entry the O ring is only required when sealing the side cable entry see previous page Alte...

Страница 25: ...www dallmeier com 25 Commissioning DDF4520HDV DN SM Connection board...

Страница 26: ...ommissioning Connection board 4 pin male connector Analogue Video OUT 12V DC Power IN Shielded RJ45 Ethernet female connector PoE IEEE 802 3af 8 pin male connector Ethernet PoE IEEE 802 3af 2 pin male...

Страница 27: ...er wiring For outdoor installations carefully remove the pre installed cable harness connector Always use the delivered outdoor cable harness Video OUT Power IN Ethernet and the PG16 cable gland inste...

Страница 28: ...e the pre installed cable harness if not used You may remove the pre installed cable harness if you want to use neither the 12V DC Power IN interface nor the analogue video output BNC connector Do not...

Страница 29: ...installation For outdoor installations carefully remove the pre installed cable harness Always use the delivered cable harness Video OUT Power IN Ethernet and the PG16 cable gland instead Power IN 12...

Страница 30: ...30 www dallmeier com DDF4520HDV DN SM Commissioning Adhere the delivered gasket to the bottom of the housing base Gasket adhesive backed Threaded blanking plug...

Страница 31: ...www dallmeier com 31 Commissioning DDF4520HDV DN SM Drill hole 3 Dowel anchor 3 O ring 3 Mounting screw 3...

Страница 32: ...eiling wall use the delivered drilling template At the marked locations drill holes fitting the used screws anchors Push anchors suitable for the ceiling wall material into the drill holes Mount the h...

Страница 33: ...www dallmeier com 33 Commissioning DDF4520HDV DN SM Run the required cables through a PG16 cable gland PG16 cable gland O ring...

Страница 34: ...DDF4520HDV DN SM Commissioning Screw the PG16 cable gland in the appropriate thread of the housing base always use the O ring for the side cable entry Connect the required cables to the connectors of...

Страница 35: ...www dallmeier com 35 Commissioning DDF4520HDV DN SM Rotation 180 Tilt 90 Pan 90 Knurled locking screw Rotation 2...

Страница 36: ...ntrol The camera is equipped with a motor driven varifocal lens The focal length zoom and the focus are adjusted over the network in the WebConfig user interface of the camera more information can be...

Страница 37: ...w dallmeier com 37 Commissioning DDF4520HDV DN SM Attach the housing to the housing base while ensuring that the ambient light sensor is not covered by the black inner dome cover Black inner dome cove...

Страница 38: ...38 www dallmeier com DDF4520HDV DN SM Commissioning Tighten the 3 torx screws of the housing with a T20 torx screwdriver...

Страница 39: ...web browser via the local area network LAN Alternatively the PC can be directly connected to the device via an Ethernet crossover cable NOTICE The configuration of the device must always be carried o...

Страница 40: ...MD Athlon 64 3400 or faster or equivalent Random access memory RAM 1GB Windows XP 2GB Windows Vista Windows 7 Graphics card DirectX 9 0 or 10 0 compatible 64MB of graphics memory 128MB or higher recom...

Страница 41: ...o ActiveX can be directly downloaded from the device the Dallmeier Live Video ActiveX can be downloaded from the Dallmeier Partner Forum the Dallmeier Live Video ActiveX can be automatically downloade...

Страница 42: ...168 2 28 Ensure that the PC web browser can establish a connection to the device via Ethernet Start the web browser Enter the IP address of the device into the address bar of the web browser Confirm t...

Страница 43: ...Risk of misuse by unauthorized users Change the factory default admin password as soon as possible Click CONFIG in the user interface of the live mode The login dialogue is displayed Enter the Userna...

Страница 44: ...Ethernet 1 RJ45 female connector 10BASE T 100BASE TX PoE Voltage supply 12V DC 10 or via PoE Class 0 PoE standard IEEE 802 3af Power consumption Max 4 5W Mechanical adjustment 3 axis mount Pan 90 Tilt...

Страница 45: ...ng temperature 20 C to 50 C 4 F to 122 F indoor and outdoor Relative humidity 0 90 RH non condensing Approvals certifications CE FCC ACA UVV Kassen DGUV Test UL DIN EN 50130 4 compliant For detailed t...

Страница 46: ......

Страница 47: ......

Страница 48: ...Dallmeier electronic GmbH Co KG Cranachweg 1 93051 Regensburg Germany Phone 49 0 941 87 00 0 Fax 49 0 941 87 00 180 www dallmeier com info dallmeier com...

Отзывы: