background image

3.AE MODE: 

Choice AE MODE on Main Menu and press left or right into submenu. Display as: 

 
 
 
 
 
 
 
 

 

AE HOLD:Exposure mode setting. Choose HOLD(Lock mode), fixed model. Or choose AUTO mode,

i.e., According to an outside light automatic correction image brightness signal strength and color signal shade. 

 

AGC LIMIT(DB):Auto Gain control. Option:LOW、MID、HIGH. Default is LOW. This parameter mainly 

for low Illu. Image. Noise is smallest when LOW mode, noise is biggest when HIGH mode. 

 

SHUTTER TIME:Shutter time(s)。Option:AUTO、1/25、1/50、1/100、1/200、1/400. The function main 

apply to take photos for rapid transit object, the fastest for shutter time, the clearest for image. To a certain 

extent, reduce tailing phenomenon.

 

 

BACK TO MENU:Cursor move to  “(––”,  press left or right to go back. 

4、

Simple troubleshooting method:

 

 
 

 

 
 
 
 
 
 
 
 
 
 
 
 

 
 
 
 
 
 

Troubles 

Reason 

Solution 

No image after power on 

No power or Plug connector is not very good 

check and make corrections 

The power consumption is not enough 

change 

Power short circuit or open circuit 

check and make corrections 

Display image but can’t 

control RS485 

Address code or protocol or Baud rate are 

wrong 

check and make corrections 

The distance of RS485 cable is more than 

500M 

 

Check the cables and make 

corrections 

The cable of RS485 is not connected well 

Transmission distance is 

short 

Make sure the transmission cable is suitable 

for RG59 standard 

Suggest to use the coaxial cable 

better than RG59 

Only B/W image 

Check the setting of menu if B/W mode 

Change B/W mode to auto mode 

AE MODE 

AE HOLD 

AGC LIMIT (DB) 
SHUTTER TIME 

BACK TO MENU 

AUTO 

LOW 
AUTO 

(– – 

Отзывы: