SLIM 2CV CASAMBI
PRELIMINARY
Device Manual
Made in Italy
DALCNET S.r.l.
36077 Altavilla Vicentina (VI)
–
Italy
Via Lago di Garda, 22
Phone +39 0444 1836680
–
Rev.
06/09/2022 -
Pag.
6/9
LOCAL COMMANDS FUNCTIONALITY
COMMAND BUTTON N
.
O
N° Button
Function
1
Check a lamp
Click
Long pressure (>1s)
Press to turn the lamp on or off
–
press and hold to
adjust the brightness
Check an item
Click
Long pressure (>1s)
Press to activate or deactivate the lamp
–
hold to
adjust the value of the element
Check a group
Click
Long pressure (>1s)
Press to activate or deactivate a group
–
press and
hold to adjust the brightness
Check a scenario
Click
Long pressure (>1s)
Press to turn a scenario on or off
–
press and hold
to adjust the brightness of the scenario
Check all lamps
Click
Long pressure (>1s)
Press to activate or deactivate all lamps
–
press and
hold to adjust the brightness
Sequence of scenarios
Click
Long pressure (>1s)
Press to scroll through the list of scenarios
–
press
and hold to adjust the brightness of the current
scenario
Activate/Standby
Click
Long pressure (>1s)
Press to switch between scenarios
–
press and hold
to adjust the brightness of the current scene
For all other functions consult the documentation of the CASAMBI APP at:
https://support.casambi.com/support/home
UNPAIR DEVICE FROM THE CASAMBI NETWORK
If the device is associated with a network to which you do not have credentials and you want to associate it with a new one, follow
the settings specified in the Casambi APP in the "Nearby Devices" section. Once the unpair function has started and the procedure
has begun, turn off the main power of the power supply connected to the MINI-1CV-CASAMBI and turn it back on within 1
–
2
seconds.
If you turn the main power of the power supply off and on quickly, the unpair may not occur correctly. Repeat the unpair sequence
by allowing 1 or 2 seconds more to elapse between the moment you turn off and re-on the main power supply
5
.
In the event that it is difficult to perform decoupling, it is possible to associate a N.A. button to the "INPUT" input of the MINI-1CV-
CASAMBI and during the decoupling procedure press the button.
POSITIONING Tc POINT
Bottom
under the LED output connector.
5
The discharge time of the power supply secondary depends on the construction characteristics of the power supply used.