DALCNET DLM Series Скачать руководство пользователя страница 5

DLM 

Single Channel

BUS

Device Manual    

EASY-BUS

                       

FW 1.2

 

Made in Italy

Rev. 2018-07-23

pag. 5/11

LOCAL COMMAND

PUSH DIMMER FEATURE

The intensity and the status change (ON/OFF) are controlled by the N.O. push button.

Button

Intensity

Click
Double Click
Long pressure (>1s) from OFF
Long pressure (>1s) from ON

On/Off
Maximum intensity
Turn ON at 1% (Nightly Time), then dimmer up/down
Dimmer up/down

15 Click in 5 second-time

Enter in to PUSH MENU’

0-10V & 1-10V & POTENTIOMETER FEATURE

The intensity is controlled by input voltage variation.

 

Input 

Intensity

0÷10V
1÷10V
Potentiometer 10K

Dimmer: 0-1V=0%                                                                                                                      10V=100%

ANALOGIC AUTOMATIC DETECTION

   

AUTOMATIC DETECTION OF THE TYPE OF LOCAL COMMAND

At the first switch the device is set by default to automatic recognition of push button N.O. command.

AUTOMATIC DETECTION OF THE 0/1-10V & POTENTIOMETER COMMAND

The automatic recognition of analog signal 0/1-10V or potentiometer starts as soon as a 0/1-10V value between 3V and 7V is sent out or setting the 
potentiometer with a value included from 30% and 70%.

0-10V COMMAND

1-10V COMMEND

POTENTIOMETER

AUTOMATIC DETECTION OF THE N.O. PUSH BUTTON COMMAND

The N.O. push button is identified automatically after 5 clicks in rapid sequence. 
In mode N.O. push button, function memory is always active.

N.O. PUSH BUTTON

DLM 1248 singolo canale BUS

 

LED DRIVERS

DALCNET S.r.l.

Registered office: via Meucci, 35 - 36040 Brendola (VI) - Italy 

Headquarters: via Meucci, 35 - 36040 Brendola (VI) - Italy 

Tel. + 39 0444 1836680/1867452 Fax. + 39 0444 1867453 

VAT: IT-04023100235 

[email protected] www.dalcnet.com

IN

COM

INPUT

0-10V

+               - 

BUS

IN

COM

INPUT

1-10V

+               - 

BUS

POTENTIOMETER

  

10K

Ω

  

IN

COM

INPUT

BUS

PUSH BUTTON N.O

IN

COM

INPUT

BUS

M

 U

 L T

 I      

                               I N

 

P

 

U

 

IN

A N  A L  O  

G  

I C  

         

         

A  

U

 

T  

O

 

M

 

A

 

T

 

I  C  

       

       

       

   D  

E  

T  

E  

C  

T  I 

O  

PA TENT 

PENDING

Содержание DLM Series

Страница 1: ...n N 1 analog signal 0 10V N 1 analog signal 1 10V N 1 potentiometer 10KOhm DLM1224 1CV DALI 12 24V DC 1 x 10A 1 DALI DLM1248 1CV DMX 12 48V DC 1 x 6 5A 1 DMX N 1 N O Push Button N 1 analog signal 0 10V N 1 analog signal 1 10V N 1 potentiometer 10KOhm DLM1224 1CV DMX 12 24V DC 1 x 10A 1 DMX The LED Dimmer is produced by default with Analog Automatic Detection of local command set as N O Push Button...

Страница 2: ... DLM1248 1CV DALI or DMX Variant DLM1224 1CV DALI or DMX Variant Constant voltage Constant voltage Supply voltage min 10 8 Vdc max 52 8 Vdc min 10 8 Vdc max 26 4 Vdc Output voltage Vin Vin Output current 6 5A 40 C 1 10A 40 C 1 Absorbed nominal power 1 12V 78 W 120 W 24V 156 W 240 W 48V 312 W Power loss in stand by mode 500mW 500mW Type of Load R L C R Thermal shutdown 2 150 C D PWM dimming frequen...

Страница 3: ...8 singolo canale BUS LED DRIVERS DALCNET S r l Registered office via Meucci 35 36040 Brendola VI Italy Headquarters via Meucci 35 36040 Brendola VI Italy Tel 39 0444 1836680 1867452 Fax 39 0444 1867453 VAT IT 04023100235 info dalcnet com www dalcnet com SWITCHING SUPPLY Vout L N 230V DALI DC IN N O PUSH BUTTON DALI In 12 48V Out max 8A DC IN OUT DALI DA DA INPUT COM 0 10V COMMAND DMX In 12 48V Out...

Страница 4: ... a protection against over current between the power supply and the device Command The length of the connection cables between the local commands N O Push button 0 10 V 1 10 V Potentiometer or other and the product must be less than 10m the cables must be dimensioned correctly and they should be isolated from every wiring or parts at voltage not SELV It is suggested to use double insulated shielde...

Страница 5: ...nd AUTOMATIC DETECTION OF THE 0 1 10V POTENTIOMETER COMMAND The automatic recognition of analog signal 0 1 10V or potentiometer starts as soon as a 0 1 10V value between 3V and 7V is sent out or setting the potentiometer with a value included from 30 and 70 0 10V COMMAND 1 10V COMMEND POTENTIOMETER AUTOMATIC DETECTION OF THE N O PUSH BUTTON COMMAND The N O push button is identified automatically a...

Страница 6: ... 2 POWER ON RAMP FADE IN Every single click make it changing the power on ramp There are five levels of power on ramp FADE IN instantaneous 1 second 2 seconds 3 seconds 6 seconds After setting the FADE IN press a long to confirm Three flashes confirm the storage and you can go to MENU 3 MENU 3 POWER OFF RAMP FADE OUT Every single click make it changing the power off ramp There are five levels of p...

Страница 7: ...ol is active When the BUS is detected the control passes to the BUS In the absence of signal the control passes to local commands in the event of the button pressure ADDRESSING Simplified method One ballast connected at a time Random Address Allocation ADDRESSES MAP The intensity and the status ON OFF is controlled by a DALI controller Address Function Value 1 Dimmer Intensity 0 254 Intensity 0 25...

Страница 8: ...ROUP 0 to 15 REMOVE FROM GROUP 0 to 15 STORE DTR AS SHORT ADDRESS ENABLE WRITE MEMORY QUERY STATUS 1 QUERY BALLAST QUERY LAMP FAILURE 1 QUERY LAMP POWER ON QUERY LIMIT ERROR QUERY RESET STATE QUERY MISSING SHORT ADDRESS QUERY VERSION NUMBER QUERY CONTENT DTR QUERY DEVICE TYPE 2 QUERY PHYSICAL MINIMUM LEVEL QUERY POWER FAILURE QUERY CONTENT DTR1 QUERY CONTENT DTR2 QUERY ACTUAL LEVEL QUERY MAX LEVEL...

Страница 9: ...o change SEARCH ADDRESS FF FF FF FF FF FF RANDOM ADDRESS FF FF FF FF FF FF GROUP 0 7 0 0 GROUP 8 15 0 0 SCENE 0 15 MASK MASK STATUS INFORMATION 1 0 0 100 VERSION NUMBER 1 no change PHYSICAL MIN LEVEL 1 no change DLM 1248 singolo canale BUS LED DRIVERS DALCNET S r l Registered office via Meucci 35 36040 Brendola VI Italy Headquarters via Meucci 35 36040 Brendola VI Italy Tel 39 0444 1836680 1867452...

Страница 10: ...ntrol is active When the BUS is detected the control passes to the BUS In the absence of signal the control passes to local commands in the event of the button pressure ADDRESSING RDM Notice device addressing have to be carried out by a DMX RDM programmer CHANNEL MAPS The intensity and the status ON OFF is controlled by a DMX controller Channel Function Value 1 Dimmer Intensity 0 255 Intensity 0 2...

Страница 11: ...RAMETER_DESCRIPTION BOOT_SOFTWARE_VERSION_ID DEVICE_INFO BOOT_SOFTWARE_VERSION_LABEL SOFTWARE_VERSION_LABEL DMX_PERSONALITY DMX_START_ADDRESS DMX_PERSONALITY_DESCRIPTION IDENTIFY_DEVICE SLOT_INFO SLOT_DESCRIPTION DEFAULT_SLOT_VALUE DLM 1248 singolo canale BUS LED DRIVERS DALCNET S r l Registered office via Meucci 35 36040 Brendola VI Italy Headquarters via Meucci 35 36040 Brendola VI Italy Tel 39 ...

Отзывы: