Recommended connection 3 phases (N3)
•
380-415V mains three-phase connection with operating
neutral conductor.
•
-Bridge connects the terminals 4-5.
•
-Phase sequence according to 1-2-3.
•
-Neutral conductor on 4 and 5.
12.4
Installing the oven
Connect the oven to the mains power supply.
•
Slide the oven a little into the previously prepared
conversion cabinet and connect it to the hob.
•
Connect the red and white plugs of the hob,
corresponding to 1 red and 3 white on the upper edge of
the oven. See Fig. 8 Upper edge of oven
•
Slide the oven completely into the conversion cabinet.
Secure in this position with four screws at the points
shown in the sketch (Fig.11).
Final inspection
Set all switches on the cooker to "0"
•
Switch on the fuse for the cooker power circuit again
•
Set the clock on the timer (depending on model)
•
Switch on the cooking zones and oven and check the
function
ELECTROCUTION HAZARD!
Switch off or unscrew the fuse for the cooker
power circuit.
Figure 10 3 phases N3
Correct
incorrect
Figure 12 Hob to oven plug
connection