OFF
1
2
3
4
5
6
50
ENGLISH
CONTROL PANEL
BUTTON
ON/OFF
DISPLAY OF THE VARIOUS
TEXT MESSAGES
TO ACCESS
THE MENU
TEMPERATURE
SETTINGS
DISPLAY ICON KEY
Indicates the reception of the radio signal
Off: radio communication absent
On: radio communication present
Indicates the status of the additional thermostat input (GND - l3)
Indicates the status of the fumes motor.
Off: motor disabled
On: motor enabled
Flashing: failure
Indicates the operation of the ducted motor
Off = motor disabled
On = motor enabled
Flashing = the motor is operating at minimum speed, it is in
modulation (additional input open)
1
Indicates the operation of the tangential fan (where present)
Off = not working
On = working
Flashing = motor at minimum speed
Indicates the activation of the F1 function (future set-up)
Off = function disabled
On = function enabled
Indicates the status of the pellet loading motor
Off: motor disabled
On: motor enabled
Indicates the status of the weekly programming
Off: disabled
On: enabled
Indicates the compensation function
Off = the function is disabled
On = the function is enabled
Indicates the stove modulation
On = the stove is operating at the set power
Flashing = the power at which the stove is operating is not the set
power, the stove is modulating (for different reasons)
Indicates contact of the external additional thermostat
Contact closed:
the contact of the external additional
thermostat is closed and the STAND-
BY function is disabled
Contact open:
the contact of the external additional
thermostat is open and the STAND-BY
function is disabled
Flashing with closed
contact:
the contact of the external additional
thermostat is closed and the STAND-
BY function is enabled
Flashing with open
contact:
the contact of the external additional
thermostat is open and the STAND-BY
function is enabled
Indicates the presence of an alarm.
Off: indicates that there are no alarms
On: indicates the presence of an alarm
Flashing: indicates the deactivation of the depression sensor.
Indicates the status of the room temperature
Off = the T° measured by the probe is higher than the set
temperature
On = the T° measured by the probe is lower than the set
temperature
Hopper probe
Off = probe ok
On = probe faulty (short or open)
Flashing = modulation caused by hopper
ADJUSTING
OPERATING POWER