Version 3 Software Operation
12
SI-32 Mode Setup
The SI-32 has a DIP switch to
select different operating
modes. The location of the DIP
switches is shown in
Unplug the SI-32 power cord
before removing the panel. Set
the DIP switches to the required
mode noted in
.
Toggle Mode
Toggle mode is based on the
action of a switch contact
closing or opening.
• If switch contact X is
closed, message X
will be continuously
displayed.
• If switch contact X is opened, message
X will be blanked on the display.
• If multiple switch contacts are closed,
the messages will cycle through in
the same order the switch contacts
were closed. When cycling, the time
each message remains displayed is
determined by the hold time configured
using the Venus
®
1500 Software.
When using toggle mode, set all the DIP
switches to the “OFF” position as shown in
.
SPST Switch
SPST mode will control one message per switch. When a switch is turned on, the
corresponding message will run until that switch is turned off. When multiple switches are
activated, each message will run in the same order the switches were activated until the
switches are turned off.
SPDT Switch
SPDT mode will control two messages per switch. Each switch has two “ON” settings (one
for each of two messages). When a switch is set to either “ON” position, it will run that
message until set to “OFF,” or when the adjacent message is run. Multiple messages can
be selected, but not both messages on the same switch.
Figure 11:
SI-32 DIP Switch Location
Figure 12:
SI-32 DIP Switch Settings: Toggle
Mode