Mechanical and Electrical Installation
6
6. Outdoor displays:
Use a 6-conductor cable from the SI-32 (TB9) to the RS422 IN at the
display. The signal cable will be wired one-to-one from the SI-32 to the display input.
(See your display installation manual for RS422 input location.)
7.
Connect additional displays per your display’s installation manual.
Switches to SI-32
The switches are NOT supplied by Daktronics.
Note:
Each switch input has a P and an N connection, which are connected to an
in5V and ground respectively.
Note:
Set the DIP switch to the correct setting before powering up the switch
interface. The switch setting is only recognized on boot-up. If you change the
switch setting, recycle power to the unit.
SPST
Each SPST switch connects to
one switch input and controls
one message. Refer to the
OSI-
32 Wiring Diagram
.
1.
Connect one N.O.
(Normally Open) terminal
of the SPST switch to SW1-P
and connect the other C
(Closed) terminal to SW1-N
2.
Connect all other SPST
switches per
Step 1
.
Figure 5:
RS422 Layout
Figure 6:
SPST Mode Connection (Toggle Switch Shown)