Daktronics LARGE MATRIX GALAXY GS6 Series Скачать руководство пользователя страница 4

– ii –

Table of Contents

Controller Diagnostics .............................26
PLR Diagnostics  .......................................26

PLR Self-Test �������������������������������������������26

Module Diagnostics .................................27

Module Self-Test �����������������������������������27

12  Replacement Parts List ���������������������28
13  Replacing Parts ���������������������������������29

Module Replacement .............................29
Power Supply Replacement ..................29
Controller Replacement .........................29
PLR Replacement ....................................30

14  Daktronics Exchange and Repair & 

Return Programs ��������������������������������31

Exchange Program .................................31

Before Contacting Daktronics �������������31

Repair & Return Program ........................32

Shipping Address ����������������������������������32

Daktronics Warranty and Limitation of 

Liability ......................................................32

A  Reference Drawings �������������������������33
B  Daktronics Warranty and Limitation 

of Liability�������������������������������������������35

C  Legacy Remote Display 

Configuration

 ������������������������������������37

Connecting A Display to A DHCP 

Network.....................................................37

Display Currently Configured for DHCP 

(Default) �������������������������������������������������37

Network Requirements .....................37
Installation/Start-up Steps.................37

Display Configured For Static IP 

Address ��������������������������������������������������37

Network Requirements .....................37

Configuration Steps Using IP Address

 �37

Installation/Start-up Steps.................37

Display Configured For Static IP 

Address ��������������������������������������������������37

Network Requirements .....................37

Configuration Steps Using IP Address

.............................................................38

Configuration Using DisplayFind To 

Discover The Display ����������������������������39

Downloading DisplayFind ................39
Launching DisplayFind ......................39

Connecting To A Display ..................40

Connecting A Display To A Static IP 

Network.....................................................41

Display Currently Configured for DHCP 

(Default) �������������������������������������������������41

Network Requirements .....................41

Configuration Steps Using IP Address

.............................................................41

Display Configured For Static IP 

Address ��������������������������������������������������42

Network Requirements .....................42

Configuration Steps Using IP Address

.............................................................42

Содержание LARGE MATRIX GALAXY GS6 Series

Страница 1: ...201 Daktronics Drive Brookings SD 57006 5128 www daktronics com support 800 325 8766 LARGE MATRIX GALAXY GS6 SERIES INSTALLATION AND OPERATION MANUAL P1874 DD3125389 Rev 12 20 March 2020...

Страница 2: ...limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a com...

Страница 3: ...A Display to A DHCP Network 12 Display Currently Configured for DHCP Default 12 Network Requirements 12 Installation Start up Steps 12 Display Configured For Static IP Address 12 Network Requirements...

Страница 4: ...ecting A Display to A DHCP Network 37 Display Currently Configured for DHCP Default 37 Network Requirements 37 Installation Start up Steps 37 Display Configured For Static IP Address 37 Network Requir...

Страница 5: ...et or the control system Refer to Section B Daktronics Warranty and Limitation of Liability p 35 at the end of this manual for the full Daktronics Warranty and Limitation of Liability Contact Informat...

Страница 6: ...holes accidental or intentional that will allow water to enter the display All display modules are fully latched into the display cabinet Structure Requirements Support structure design depends on mou...

Страница 7: ...cialized tools needed to complete the installation Daktronics Provided Customer Provided Splice Wrench Hex Head Wrenches 1 8 and 3 16 Flathead and Phillips Head Screw Drivers Crane or Lift Truck Step...

Страница 8: ...display ventilation system Do not use the lift eyes for display mounting Do not hang additional signage from GS6 display Display Installation 1 Use a utility knife to carefully cut away all of the whi...

Страница 9: ...display The T Clips are installed in the recommended locations at Daktronics but can be moved 12 inches either way to avoid obstructions Refer to the label on the display for limitations 9 Remove cra...

Страница 10: ...Lift the display top section off the truck high enough to spin around 180 degrees 5 Starting at one end of the display use the splice tool to draw the top section into the bottom until the splice key...

Страница 11: ...local and national electrical codes Do not share circuits between displays and other electrical devices Do not connect the display to any voltage other than that listed on the product label Do not con...

Страница 12: ...connected near the point of power connection Locate the disconnecting means either in a direct line of sight from the display or so it can be locked in the open position This ensures that power is not...

Страница 13: ...nt must be electrically grounded Only qualified individuals may perform electrical work including verification of ground resistance Daktronics is not responsible for improper grounding or damage incur...

Страница 14: ...isplay to the Mirror display the fiber interconnect cable must be connected This cable typically comes attached to the back of the display 1 Locate cable and unpackage 2 Connect one end of the cable t...

Страница 15: ...d State MAC Address Configuration Port Status Port Management Port Used to Access Configuration Description Start Up Checklist Confirm power is correctly connected to the display Confirm there is suff...

Страница 16: ...lay is connected to a network that supports DHCP a default DHCP name similar to DMP8 xx xxxx or DMP5 xx xxxx where xxxx represents a unique identifier for the display This information is shown in the...

Страница 17: ...13 87 85 to identify the correct connection port 5 Enter User Name Dak and Password DakPassword in the Windows Security window 6 Click OK to connect to the display refer to the help file for addition...

Страница 18: ...utility should have a green check mark See the explanations below for what each item means If an item has a red X next to it click it for additional information or to access the download The Current...

Страница 19: ...ted in the bottom window of the utility 4 Click the desired display VIP5 xx xxx to launch the configuration utility within your web browser Note Refer to the configuration utility help file for additi...

Страница 20: ...timeout searching for a DHCP server and fall back to auto IP addresses of 169 25x x x 4 Observe boot sequence reconfigure computer to same in the IP address range as the display and same subnet 5 Manu...

Страница 21: ...nfigured For Static IP Address The following steps explain how to update the static IP address that is currently set on the display Network Requirements Existing Network Available network port configu...

Страница 22: ...p file for additional information about the configuration utility 7 Click the Network tile 8 Change the IP address settings to new values 9 Click the Save button 10 Click Upload Configuration 11 Turn...

Страница 23: ...Login Refer to Figure 14 3 Change the password in the Update Password window Refer to Figure 13 This step is required only for the first time login to the Venus Control Suite system 4 Update the acco...

Страница 24: ...ed data packages Scripts Opens the Script Library where display commands are created and stored Accounts Creates new accounts for advertisers Users Lists current user profiles and allows users to upda...

Страница 25: ...is required Daktronics Customer Service is available 7 a m to 7 p m CST Monday to Friday via telephone or online connection Telephone Domestic U S and Canada 1 800 DAKTRONICS 1 800 325 8766 Internati...

Страница 26: ...module upward to disengage the tabs at the bottom of the module from the slots on the display s face sheet 4 Disconnect the SATA cables and unplug the power cable by squeezing the tabs on the sides of...

Страница 27: ...ounce of detergent to one gallon of cold water 3 Saturate a light medium duty cleaning brush with the soapy water 4 Use horizontal brush strokes to loosen and remove dirt and grime washing the display...

Страница 28: ...splay through the power entrance box on the back of the display and travels to the Power Termination Panel 2 Power is distributed to Module Power Supplies 2a Player Power Supply 2b Thermostat 2c and F...

Страница 29: ...yer from Fiber A to the PLR Port A 3 4 From SATA A on the PLR signal goes to the first module 4a and travels from module to module via SATA cables 4b finally returning to the PLR to SATA B 4c 5 Signal...

Страница 30: ...into self test mode loop a SATA cable between ports A and B Then take a fiber cable and connect the fiber ports together Refer to Figure 24 Once the cables are connected cycle power to the PLR and it...

Страница 31: ...s Module Self Test If a module is blank but has power supplied to it perform a module self test to diagnose a module or signal cable failure To perform a self test follow the steps below 1 Attach a si...

Страница 32: ...18 Light Sensor Assembly 0A 1815 5020 26 42 mm Red Module A 3143 12 Volt Power Supply 0A 1814 5010 15 85 mm Amber Module EN 2241 Air Filter 3 625 x 32 x 75 0A 1792 5011 19 81 mm Amber Module EN 2242 A...

Страница 33: ...ule using a 1 8 hex head wrench Note A fully seated module should be flush with the modules around it Power Supply Replacement 1 Disconnect the power supply from any wiring harnesses connected to it 2...

Страница 34: ...bottom in the first column of modules Refer to Figure 18 If the display has two PLRs they are located in behind the third and fifth columns PLRs can be found in both Primary and Mirror display faces...

Страница 35: ...eceived mail the old part to Daktronics If the replacement part fixes the problem send in the problem part which is being replaced a Package the old part in the same shipping materials in which the re...

Страница 36: ...damage during shipment Electronic components such as printed circuit boards should be placed in an antistatic bag before boxing 4 Enclose Your name Address Phone number The RMA number A clear descript...

Страница 37: ...am Block Diagram GS6 13 03 Large Matrix w DMP DWG 3088134 Block Diagram GS6 SATA Routing 1 PLR Per Section DWG 3054464 Block Diagram GS6 SATA Routing 2 PLR Per Section DWG 3106357 Block Diagram GS6 Ge...

Страница 38: ...This page intentionally left blank...

Страница 39: ...Daktronics Warranty and Limitation of Liability 35 B Daktronics Warranty and Limitation of Liability Click here to view Warranty and Limitation of Liability SL 2374 information...

Страница 40: ...This page intentionally left blank...

Страница 41: ...ed For Static IP Address The following steps explain how to reconfigure a display for DHCP network when it has previously been configured for a static IP address Network Requirements Existing Network...

Страница 42: ...ttp display IP address 85 5 Enter User Name Dak and Password DakPassword in the Windows Security window 6 Click Logon to connect to the display refer to the help file for additional information about...

Страница 43: ...at the top of the DisplayFind utility should have a green check mark See the explanations below for what each item means If an item has a red X next to it click it for additional information or to ac...

Страница 44: ...d in the bottom window of the utility 4 Click the desired display VIP5 xx xxx to launch the configuration utility within your web browser Note Refer to the configuration utility help file for addition...

Страница 45: ...uter for DHCP 3 Turn on the display Both the display and the computer should timeout searching for a DHCP server and fall back to auto IP addresses of 169 25x x x 4 Observe boot sequence reconfigure c...

Страница 46: ...Disconnect the computer from the display and connect display to the network 16 Ensure the display has an established link with the network 17 Turn on the display Display Configured For Static IP Addr...

Страница 47: ...o Discover The Display p 39 section 5 Enter User Name Dak and Password DakPassword in the Windows Security window 6 Click the Configuration tab 7 Click eth0 8 Change the IP address settings to new val...