background image

Fuelight

TM

 FL-3000 and FL-4500 Petroleum 

Display Installation Quick Guide

DD2238842
Rev 08
06 February 2019

201 Daktronics Drive

Brookings, SD 57006-5128

www.daktronics.com/support

800.325.8766

Page 4 of 4

3. 

The power supply is attached inside the cabinet to the display’s backsheet, as shown in 

Figure 12

and its location varies between display sizes. 

Grounding

Cash/Credit displays do not require a local earth ground electrode.

The displays still require a safety ground from the electrical service panel for the primary power wires to 

comply with national electric codes. 

Cash/Credit Display Power Installation

Install Daktronics Cash/Credit displays using a two-wire plus 

ground circuit. The ground from the circuit must be connected 

to the grounding stud within each Cash/Credit display. Do not 

connect neutral to ground at the disconnect or at the display, 

this would violate electrical codes and void the warranty. 

Use a disconnect so that all ungrounded conductors can be 

disconnected.
To connect power to the display, complete the following steps:

1. 

Route power cable into the display through one of the 

knockouts on the display’s backsheet.

2. 

Use wire nuts or other appropriate hardware to connect 

power wires to the power supply harness or pigtail. Refer to 

Figure 13

.

3. 

Connect supply power ground wire to the grounding stud. 

Refer to 

Figure 13

.

Note: 

Verify the power supply ground wire is connected to 

the grounding stud.

Connect Cash/Credit Display to the Fuelight Driver

Connect the 8 position Mate-N-Lok plug of harness W-2709 from 

the cash/credit module to jack J18 on a Fuelight driver. Refer to 

Figure 14

.

Use 

Grounding

Stud

SERIAL #

LABEL B

LABEL A

LABEL C

Figure 12: 

 Internal Component Locations

Figure 13: 

Power Connection

Figure 14: 

Cash/Credit Display 

Connection to Driver

Отзывы: