background image

DVX-1830 Series Sectional  

Installation Quick Guide

28 November 2016
DD3396953
Rev 00

201 Daktronics Drive Brookings SD 57006

800.325.8766

www.daktronics.com/support

Page 4 of 8

Center Adjustment

Corner blocks provide proper spacing at the ends of section seams, 

but spacing may vary in the middle where the sections come together. 

Additional holes are provided along both the horizontal and vertical edges 

of the cabinet for further adjustment if required. Install hardware in these 

locations only if further seam adjustment is required.
For wide center seams, install 

1

/

4

″ bolts (located in the blue interconnect 

hardware bag) through the holes behind the face sheets at the problem 

locations in the bottom of the top cabinet or the left side of the right cabinet 

and into the next cabinet’s nutsert. Tighten these bolts until the seam is 

within tolerance. Refer to the 

DD3008872 DVX-11X2/1502/1801 Series Seam 

Measurement Field Instructions for details on seam tolerance and to Figure 11 

on page 4

 for details on seam adjustment.

For tight center seams, install 

1

/

4

″ bolts (located in the blue interconnect 

hardware bag) into the pre-installed nutserts behind the face sheet at the 

problem locations in the bottom of the top cabinet or the left side of the right 

cabinet. Tighten the bolts until the seam is within tolerance. Refer to the 

DD3008872 DVX-11X2/1502/1801 Series Seam Measurement Field Instructions 

for details on seam tolerance and to Figure 12 on page 4 for details on 

seam adjustment.

Figure 11: 

Adjusting Wide Center 

Seams

Figure 12: 

Adjusting Tight Center 

Seams

Содержание DVX-1830 Series

Страница 1: ...ermanently attaching to the structure Refer to Figure 2 on page 1 for connection details 4 Secure the section until it is permanently attached to the structure using only one of the two methods descri...

Страница 2: ...cent sections Refer to Figure 6 on page 2 If they are no longer aligned loosen the section interconnect hardware and repeat Steps 4 7 8 Attach the clips to the structure by either welding or installin...

Страница 3: ...flush and aligned 6 Use a 4 level to ensure the display faces are flush and flat to all adjacent sections Refer to Figure 6 on page 2 Top to Bottom Connection 1 Connect the sections side to side befor...

Страница 4: ...tions in the bottom of the top cabinet or the left side of the right cabinet and into the next cabinet s nutsert Tighten these bolts until the seam is within tolerance Refer to the DD3008872 DVX 11X2...

Страница 5: ...e 15 on page 5 and the Signal Interconnect Drawing and System Riser Diagram Fiber SATA Power Ethernet Term Panel Input Quick Connect Prolink Router Power Entrance TP IQC PLR PE Digital Media Player Fi...

Страница 6: ...Drawing for routing information 5 Route the coiled power cables from section to section connecting to the power harness in the next section Refer to the Signal Interconnect Drawing Note The fiber pow...

Страница 7: ...nduits should point downward or have a fitting attached to prevent water from entering the conduit GND Alternate power and signal entrance Power in Fiber out Power and signal entrance remove hole seal...

Страница 8: ...he proper quick connect jacks on the rear of the display as necessary Verify the caps on the jacks are properly installed if the jacks are not in use Figure 27 Quick Connect Jacks ETHERNET IN J33 J35...