Diagnostics and Troubleshooting 

13 

4.2  Troubleshooting 

This section lists potential problems with the display, indicates possible causes, and suggests 
corrective action. This list does not include every possible problem, but it does represent 
some of the more common situations that may occur. (Refer to the appropriate manual for a 
list of potential problems with add-on or separately mounted message centers. 

 

Symptom/ 

Condition 

Possible Cause 

Solution 

No displays in the 

sign will light 

 

Power incorrectly set up.

 

 

 

 

Addresses not set correctly.

 

 

Open display with host driver 

and check Power LED 

(Section 4.2). 

 

Check each driver to verify 

correct address settings 

(Section 3.2). 

Multiple line sign 

with all lines 

showing same 

prices 

 

Addresses not set 

correctly. 

 

Set up different address for 

each line of sign (Section 3.2). 

Digit will not light 

 

Black wire to digit broken. 

 

Poor contact at driver 

connection. 

 Driver 

malfunction. 

 Replace 

harness. 

 Clean 

contacts. 

 

 Replace 

driver. 

Segment or several 

LEDs will not light 

 Broken 

LEDs. 

 Driver 

failure. 

 

Broken wire between 

driver and digit. 

 

Poor contact at driver 

connector. 

 

Replace segment or digit. 

 Replace 

driver. 

 Replace 

harness. 

 

 

Clean contact or replace 

harness. 

Segment or digit 

stays lit 

 Driver 

failure. 

 

Short circuit on digit. 

 Replace 

driver. 

 Replace 

harness. 

Data appears in the 

wrong place on the 

sign 

 

Signal connections are 

not correct. 

 

Reconnect signal wiring to 

drivers (Section 3.2).  

Data appears on the 

wrong line of the 

display 

 

Incorrect address settings 

on drivers. 

 

Change addresses on drivers 

(Section 3.2). 

Display shows "E4". 

 

No Message Error: This 

code is shown when no 

messages are 

downloaded to the 

display. 

 

Download a new message to 

the display using the [Update 

Display] key on the 

DataMaster 100 controller. 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

 

Содержание B-300561

Страница 1: ...9 Series 36 48 and 60 digits Installation and Operation Manual ED 18514 Rev 0 2 July 2007 201 Daktronics Dr PO Box 5128 Brookings SD 57006 Tel 866 343 3122 605 697 4300 Fax 605 697 4444 Hwww daktronic...

Страница 2: ...nication Network address DAKTRONICS INC Copyright 2008 All rights reserved While every precaution has been taken in the preparation of this manual the publisher assumes no responsibility for errors or...

Страница 3: ...over Page and Copyright Page are blank on back Section heading pages always start on the right hand page 3 Group and insert the drawings as listed in Appendix A Reference Drawings Print all A drawings...

Страница 4: ......

Страница 5: ...ddress Dip Switch Settings 9 3 3 Power Up Self test 9 Section 4 Diagnostics and Troubleshooting 11 4 1 Driver Location and Access 11 Driver LEDs 12 Power On Self Test 12 4 2 Troubleshooting 13 Section...

Страница 6: ...ller 33 7 1 RC 50 Operation 33 Editing the Display 33 Section 8 RC 100 Controller 35 8 1 Petroleum Price Display Operation 35 Petroleum Price Display Startup 35 RC 100 Controller Operation 36 Modifyin...

Страница 7: ...ation 7 Figure 11 Location of Signal Driver 8 Figure 12 Driver 9 Figure 13 Dip Switches 9 Figure 14 Location of Driver Inside Display 11 Figure 15 Driver Diagnostics 12 Figure 16 Locations of Internal...

Страница 8: ......

Страница 9: ...sume little power some barely more than a household lamp Figure 2 DF 2109 with Top Caption The DF 2009 and DF 2109 displays are two models of DataMaster Petroleum Price displays These models include d...

Страница 10: ...drawing Figure 4 This reference number includes the last set of digits and the letter preceding them The drawing in this example would be referred to as Drawing A 244838 Figure 4 Daktronics Drawing La...

Страница 11: ...ndix A The shop drawings provide the display dimensions weight location of mounting hardware and component locations Refer to the Shop Drawing for the specific display type and size when planning the...

Страница 12: ...fting the Display Eyebolts may be removed once the display is in place Replace the eyebolts with 1 2 13 bolts 2 3 Mounting Displays Mechanical installation consists of mounting the display onto horizo...

Страница 13: ...as illustrated in Figure 8 providing power and ground to a disconnect near the display routing power and ground from the main disconnect to the display connecting the display ground to a ground rod at...

Страница 14: ...ystem must be connected to an earth electrode installed at the display Proper grounding is necessary for reliable equipment operation It also protects the equipment from damaging electrical disturbanc...

Страница 15: ...display is not in use The controller should also be disconnected from power and from the signal j box when the system is not being used The same surges that may damage the display s driver can also d...

Страница 16: ...is driver receives its signal directly from the controller on the Signal In connector J6 The Signal Out connector J8 is used to connect to client drivers the drivers in other displays in this network...

Страница 17: ...In the example switches 1 and 4 are on Addresses allow the user to set both line number switches 1 3 and sign number switches 4 6 in as many as eight sign groups All displays with the same line number...

Страница 18: ......

Страница 19: ...y not work correctly Use this section to define the problems and find solutions 4 1 Driver Location and Access The driver is located as shown in Figure 14 mounted between two digit boards To access th...

Страница 20: ...een Continuous light when driver has power DS2 Red Blinks when driver receives signal DS3 Amber Blinks when driver is running Power On Self Test A useful troubleshooting tool is the power on self test...

Страница 21: ...address for each line of sign Section 3 2 Digit will not light Black wire to digit broken Poor contact at driver connection Driver malfunction Replace harness Clean contacts Replace driver Segment or...

Страница 22: ......

Страница 23: ...W 1578 Digit cable 8 ft W 1579 Gas Price Driver 4 col 0P 1192 0394 Signal Surge Card 0P 1356 0001 Power supply 24 V DC 1 KW A 1856R Segment Breakout Board 0P 1192 0397 10 Cash Credit Board Red 0P 131...

Страница 24: ...n D male 0A 1196 0099 RC 50 Radio 0A 1356 0064 Receiver card 0P 1192 0355 Antenna A 2015 Transformer wall pack T 1118 RC 100 Price Display insert LL 2617 RC 100 hand held assembly 0A 1110 0046 RC 100...

Страница 25: ...enter digits 2 Disconnect and label all connectors from the driver Release each connector by squeezing together the locking tabs and pulling on the plug 3 Remove the screws and nuts securing the drive...

Страница 26: ...he defective segment As with smaller digits the segment circuit boards are mounted to the back of the digit panel Do not attempt to remove individual LEDs Replace a malfunctioning colon decimal or ind...

Страница 27: ...in one way only Do not attempt to force the connection 6 Close and secure the digit panel and test the display Replacing a Breakout Board To replace a breakout board follow these steps 1 Open the spec...

Страница 28: ...s Customer Service 866 343 3122 2 When the new exchange part is received mail the old part to Daktronics If the replacement part fixes the problem send in the problem part which is being replaced a Pa...

Страница 29: ...on RMA number before shipping This expedites repair of the part 3 Package and pad the item carefully to prevent damage during shipment Electronic components such as printed circuit boards should be pl...

Страница 30: ......

Страница 31: ...aster DM 100 The DM 100 can be configured to display petroleum price motel rates and time and temperature data Refer to Drawing B 256001 for information on possible control options and connection proc...

Страница 32: ...where required This control option does not require the controller to be connected to a power outlet In this configuration the DM 100 uses the sign as a power source To operate the display using this...

Страница 33: ...ide it into the DM 100 pocket Use this as a reference until a replacement is received To start the controller and use the insert to program information into the display driver read the next section ca...

Страница 34: ...the bottom line of the LCD during startup do nothing The controller will automatically default to previous Gas Price settings If a function other than GAS PRICE was shown on the bottom line of the LC...

Страница 35: ...g the Edit key during operation or by using the Menu key refer to Menu Items chart following this screen The following keys identify items to be edited L Current line number to be edited D CC Current...

Страница 36: ...play For further details refer to Modifying Price Line Settings discussed previously in this section For more information about the Modem Settings submenu refer to ED 13953 DataMaster Modem Installati...

Страница 37: ...d to the DM 100 The LCD will scroll through the status sent back from the display Following is a list of responses Firmware Version This is the firmware version programmed on the host MASC driver in t...

Страница 38: ...Enter key when finished editing Press the Clear key to cancel changes After setting the time you will need to set the date If the date is already correct enter through the date and press Enter to sen...

Страница 39: ...is shown on the bottom line of the LCD LCD Screen Action DIMMING AUTOMATIC Press the down arrow key to toggle through dim settings Automatic The display automatically dims based on the light detected...

Страница 40: ...ust be connected to the display Press Enter to accept this intensity If the manual dimming mode is selected this will be the new intensity for the display If the automatic dimming mode is selected the...

Страница 41: ...ess and hold any button for five seconds When the sign is in Edit mode the decimal LEDs blink Figure 26 RC 50 Controller On the RC 50 each pair of buttons corresponds to a price line on the display Ea...

Страница 42: ......

Страница 43: ...m RC 100 DataMaster Drawing A 244838 8 1 Petroleum Price Display Operation The RC 100 controller can be configured to program petroleum price variances displayed on the LED DataMaster Petroleum Price...

Страница 44: ...er should now be ready for use The controller will remember the last function setting so this step should only need to be done with a new controller or one that is configured for different displays To...

Страница 45: ...Current tenths of cent value to edit LCD Screen Action EDIT LINE L D CC T 10 Press any of the number keys to edit the price value for this line Press the down arrow key to modify the value of the 1 1...

Страница 46: ...e display dimming level is set manually Once set this value remains regardless of the level of light detected at the display Blank Sign The display can be blanked out without powering down Refer to th...

Страница 47: ...NK THE SIGN ENT YES CLR NO Press Enter to accept this option The next LCD dialog will ask whether to blank the screen or escape The LCD toggles between Yes and No Pressing Clear resumes normal operati...

Страница 48: ......

Страница 49: ...0082 3 to provide convenient storage for the DM 100 controller When using the wall mount bracket for the DM 100 ensure that clearance is sufficient above the bracket to allow the DM 100 to be removed...

Страница 50: ...Select the POS POS INTERFACE GILBARCO GSITE Press Enter 3 e Gilbarco G Site is uniquely identified by price category Each price category corresponds to the price assigned to a particular grade servic...

Страница 51: ...eys to scroll to POS INTERFACE ALLIED Press Enter 3 llied is u nt grade service level and price level Use the keys to select a grade for the line If a line is not used select None Press Enter nd keys...

Страница 52: ...TINGS menu item POS SETTINGS ENT TO MODIFY Press Enter 2 Select the POS type by using the and keys to scroll to PAM 1000 POS INTERFACE PAM 1000 Press Enter 3 Each price in the PAM 1000 is uniquely ide...

Страница 53: ...y is configured will automatically update when the price is changed in the POS system Attempting to manually edit prices that are configured for POS control will cause the following screen to appear T...

Страница 54: ......

Страница 55: ...Schematic Enclosed 1 KW Power Supply Drawing A 299746 Display Mounting Clip Angles to Structure Drawing A 320125 Address Dip Switch Settings Drawing B 256001 Shop Drawings listed by display type and d...

Отзывы: