Display Troubleshooting
6
3 Display Troubleshooting
Remotely Cycle Power
Daktronics DB series displays ship with an integrated
SmartLink
TM
for remote power control of display
components. The SmartLink
TM
has four relays for
independent control of various components as shown
in the relay table. The DMP-8000 monitors equipment on
the network and attempts recovery via communication
between it and the SmartLink
TM
. Refer to
while
reading the relay function table:
Relay
Component
R1
ISP Enclosure
R2
DMP-8000/VIP-5160.2
R3
Display
R4
Auxiliary Power
If remote troubleshooting is desired, call Daktronics help
desk at 1-877-DAK-HELP and they can assist. Do not
press the buttons in the SmartLink
TM
to cycle power to the
components because it can take as long as an hour to
reset the relays.
Display Troubleshooting
Work with Daktronics help desk or experienced technicians to address display issues.
See the following table for troubleshooting steps.
Issue
Issue Image
Troubleshooting Steps
Content
switched
between display
sections
1.
Check the fiber interconnect cables
between the display sections because
they may be switched. Port A should be
connected to Port A. Port B should be
connected to Port B.
2.
Check the fiber cables coming from the
DMP because they may be switched.
Scattered or out
of order content
1. The SATA cable and redundant SATA
cable from the PLR to the modules may be
switched.
2. Call Daktronics help desk to verify the
translation table is correct.
R1
R3
R4
R2
Incoming
Power
RS232
Figure 7:
SmartLink
TM
Figure 8:
SmartLink
TM
Relay Bank
Содержание 65 P2210
Страница 4: ...This page intentionally left blank...
Страница 30: ...This page intentionally left blank...