Daktronics 6000 Series Скачать руководство пользователя страница 24

Control System Overview

20

9  Control System Overview

The control components are 

enclosed in the display.

Fully Embedded 

Control System

Daktronics 6000 series digital 

billboards have three major 

components. The ISP enclosure 

is located behind the third door 

from the left. Find the DMP-8065 

behind the fourth door from the 

left. The SmartLink

TM

 is mounted 

on the third door from the right. 

Display back sheets are labeled with 

component locations to make finding 

components easy. The table below 

describes each the control system 

in more detail. Refer to 

Figure 33

Figure 34

, and 

Figure 35

 while reading 

the component descriptions below.

Component

Function

Number

Thermostat

Measures the temperatures inside the ISP enclosure and turns on 

the fan or the heater as needed. 

1

Heater

Since ISP equipment is affected by lower temperatures, a heater 

prevents the ISP enclosure from going below a functional range.

2

Fan

High heat can damage some electronics, the fan cools the ISP 

enclosure to keep the equipment in a safe functional range.

3

Laptop and Cell 

Phone Outlet

Can be used to charge laptop or cell phones. Do not plug drills or 

other power tools into this outlet.

4

Door Switch

Detects if the ISP enclosure door is open. If opened, an alert will 

be created and the content will switch to predetermined content.  5

POE Ethernet 

Switch

Connects network devices and provides webcam power.

6

Z-Filter

Suppresses electrical noise in the electrical line.

7

DMP-8065

Converts content data from the Internet into a format recognized 

by the display and sends it out to the PLRs in the display.

8

SmartLink

TM

Remote power reboot device. Four relays control the following 

components: 

•  Relay 1 - ISP equipment

•  Relay 2 - DMP-8065

•  Relay 3 - Display

•  Relay 4 - Auxiliary components

Note: 

Do not cycle relays on site. Call the help desk to cycle the 

relays.

9

10

Figure 33: 

SmartLink

TM

8

Figure 34: 

DMP-8065

1

2

3

4

5

6

7

Figure 35: 

ISP Enclosure

Содержание 6000 Series

Страница 1: ...201 Daktronics Drive Brookings SD 57006 5128 www daktronics com support 800 325 8766 6000 SERIES DIGITAL BILLBOARD INSTALLATION MANUAL P1835 DD3289669 Rev 09 23 May 2019...

Страница 2: ...limits for a Class A digital device pursuant to part 15 of the FCC Rules These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a com...

Страница 3: ...Light Sensor Relocation 13 6 Webcam Mounting 14 Mounting the Webcam to the Arm 14 Standard 10 Foot Fixed Webcam Arm Installation 14 Standard 10 20 Foot Adjustable Length Webcam Arm Installation 15 In...

Страница 4: ...This page intentionally left blank...

Страница 5: ...p 27 Note This applies to initial installation only Manufacturer does not warranty relocation of displays Important Contact Information Daktronics Help Desk 1 877 DAK HELP 325 4357 Display Identificat...

Страница 6: ...ections Located three bays in from the left Display Doors Hinged doors allow easy access to internal components Control System Meraki Router DMP 8065 DMP 8065 Gen 2 No fans on DMP 8065 internal or ext...

Страница 7: ...right Spare Parts Spare parts are located inside the far left bottom door Module module tool power supply and splice tool are included Other standard service tools are not Power Entrance Box Located...

Страница 8: ...a driver board or logic card housing a module latch assembly and a louver Each module is individually removable from either the front or back of the display Module part numbers vary by pixel pitch Pr...

Страница 9: ...al proof of performance Crane Cordless drill Drill bits Hammers Ladder 6 8 10 Laptop Pry bar Ratchet tie downs come along Socket and open end wrench 11 16 Socket extension 3 Socket set Tape measure To...

Страница 10: ...nstalled prior to lifting the display to the head For ledger bracket details refer to DWG A 988359 use with offset mounts and DWG 3041598 use without offset mounts in Section A Reference Drawings p 25...

Страница 11: ...dware were sent with the display Contact the Project Manager immediately if missing installation parts 5 Verify that the lift eyes are installed and the lift eye bolts and set bolts are in place Refer...

Страница 12: ...isplay 13 Lift the display off of the truck 14 Slowly lift the display to the structure head and guide into place with tag lines 15 Lower the display along the uprights until it rests on the ledger br...

Страница 13: ...lation 9 23 Locate the top border cover caps that are fixed to the border cover for shipping Required screws are taped to the cover 24 Use supplied Tek screws to install the border caps over the lift...

Страница 14: ...sts above the bottom section 4 Continue lowering the display until it rests on the display bottom sections and the splice key is inside the display top section splice channel 5 Starting at one end of...

Страница 15: ...ay 14 Loosen the nuts that hold the vertical splice tube in place Refer to Figure 14 15 Slide the vertical splice tube so it is split evenly between the display sections 16 Tighten the vertical splice...

Страница 16: ...tion term panel Refer to Figure 18 This end of the fiber cables is already attached to the top section PLR Signal cables connect to the fiber patch panel located on the internal vertical Contactor sig...

Страница 17: ...d to the MDLS mounting arm 8 Place the MDLS assembly on the photocell mounting arm 9 Use the attachment bolts and nuts to secure the MDLS assembly to the mounting arm 10 Use tek screws to secure the M...

Страница 18: ...our saddle bolts 7 If necessary turn the webcam assembly until it will face the display when mounted Standard 10 Foot Fixed Webcam Arm Installation 1 The webcam arm ships with all hardware and arm com...

Страница 19: ...lide the two remaining channels into the vertical mounting channel on the display back 5 Place the bolting template over the bolts in the channel The bolting template is important as it makes mounting...

Страница 20: ...er and is connected with Cat 5e cable to the network switch on the router 18 Work with the NOC to ensure the camera is aligned properly If adjustment is required pivot the arm to the display face and...

Страница 21: ...splay or so it can be locked in the open position This ensures that power is not reconnected while service personnel work on the display Electrical Installation 1 Refer to the display riser diagram fo...

Страница 22: ...lays control equipment and connected peripheral equipment must be electrically grounded Only qualified individuals may perform electrical work including verification of ground resistance Daktronics is...

Страница 23: ...Modules ISP Enclosure Filters Splice Wrench sectional displays only Hex Head Wrench 1 8 L and T Handle Power Supply Spare Parts Location Doors Installation Tools Location Figure 31 Spare Parts Box in...

Страница 24: ...SP enclosure from going below a functional range 2 Fan High heat can damage some electronics the fan cools the ISP enclosure to keep the equipment in a safe functional range 3 Laptop and Cell Phone Ou...

Страница 25: ...quipment label 2 Using a flat head screwdriver turn the two 3 4 turn latches counter clockwise see Figure 36 3 The ISP Enclosure is mounted to one of the rear access doors The ISP enclosure and door c...

Страница 26: ...e power at the main breaker at the structure base 6 Verify the status lights on the surge suppressor are on 7 Check the LED indicators on the equipment in the ISP enclosure to ensure they are on 8 Ens...

Страница 27: ...ality After the display is showing content visually inspect the display for Inaccurate or off color Module edges The display is too dim or bright Modules out Incorrect content transition Modules stuck...

Страница 28: ...This page intentionally left blank...

Страница 29: ...lboard Horizontal Signal Splice DD3151286 Billboard Fixed 10 15 Webcam Arm 4 Point Mount DWG 1142216 Billboard Fixed 20 Webcam Arm 4 Point Mount DWG 1142217 Billboard Fixed 10 Webcam Arm 2 Point Mount...

Страница 30: ...This page intentionally left blank...

Страница 31: ...Daktronics Warranty and Limitation of Liability 27 B Daktronics Warranty and Limitation of Liability Click here to view Warranty and Limitation of Liability SL 02374 information...

Отзывы: