Thank you for purchasing this light fitting. Please read the instructions carefully before use to ensure safe and
satisfactory operation of this product. Please retain these instructions for future reference.
Warning
This product is Double Insulated and does not require connection to an Earth circuit.
Please read these instructions carefully before commencing any work. It is recommended that this fitting is
installed by a qualified electrician.
Install in accordance with the IEE Wiring regulations and the Building Regulations.
To prevent electrocution switch off at mains supply before installing or maintaining this fitting. Ensure other persons
cannot restore the electrical supply without your knowledge. If you are in any doubt, please consult a qualified
electrician.
This light fitting should be connected to a 5 amp fused circuit.
If replacing an existing fitting, make a note of the connections.
This product is not suitable for dimming.
This product contains non-replaceable parts and cannot be serviced. If damage occurs the part should be scrapped.
Waste electrical products should not be disposed of with household waste. Please recycle where facilities exist.
Check with your local authority or retailer for recycling advice.
This product is rated at IP65
This product is not suitable for location in or near a marine environment.
Specification
Voltage:
240V 50Hz a.c.
Lamp:
3W LED Module - Blue/30lm
IP rating:
65
Layout
Installation
•
Remove the terminal box cover and set aside for refitting later. Having identified the wiring from your existing
fitting, connect to the terminals as shown below:
•
Fit the cover in place and refit the screws. Adjust the cable to suit and tighten the gland to maintain the IP rating
of the product.
Wiring
•
Plan the desired layout of this fitting carefully, ensuring the cables will reach the distance between the
junction box and the light fitting.
•
Avoid locating any cables in positions that would cause a hazard. Position cables and outdoor rated junction
boxes (not supplied) away from areas where they may be at risk from being cut, trapped or damaged.
•
We recommend that you use H05RN-F specification cable (not supplied) which is an outdoor grade, rubber
heathed cable. The mains supply cable must have a minimum cross sectional area of 1.0mm².
•
Cables must be protected using suitable conduit or plastic trunking.
Existing fittings must be completely removed before installation of a new product. Before removing the existing
fitting,
carefully note the position of each set of wires
.
•
The product comes with a housing unit that must be fitted into the hole prior to any wiring taking place.
•
Cut the mounting hole for the unit taking care not to damage any pipes or mains cables beneath the
mounting surface.
Cutout
Void Depth
184mm x 62mm
60mm
•
Fit the housing into position and secure. This surround may be cemented in position. Wait until the cement
has set before continuing with the installation.
Switch off the power supply
at the consumer unit.
Insert and secure the Brick
Light outer casing.
Fix in place the clear lens and
metal outer frame using the
screws provided.
Switch on the power supply at
the main fuse box and test
fitting.
NEUTRAL
LIVE
BLUE (N)
BROWN (L)
SUPPLY
LIGHT FITTING