OPERATION: 

 

CONNECTING POWER: 

 

When the power is first connected to the VLC, the hands on the clock will move quickly around the dial until they 
point to 12:00. This is normal and is how the VLC calibrates the location of the clock hands. After this calibration 
mode, the VLC will begin to keep time from 12:00 until the time is updated by the VHX system. 

 
KEY OFF/ON MODE: 

 

When the key is turned off, the VLC will use its internal clock to keep track of time and move the hands 
accordingly. When the key is turned on, the VLC will update its time using time data it receives from the VHX 
system. If this time is different than the time on the VLC, the clock hands will move rapidly either ahead or back to 
adjust to this new time.  

 

Large differences in time that cause fast hand movement can be caused by several things. If the constant power 
is lost on the VHX control box, its clock will be reset changing its time in relation to the VLC stored time. Similarly 
if the time is provided by a BIM expansion module, constant power loss to this module will cause a clock reset. 
Also if the BIM expansion module that provided time became disconnected from the BIM connector on the VHX 
control box, the VLC will revert to getting the time data from VHX control box and this time may be different than 
the time previously provided by the BIM module. 

 

SETTING THE CLOCK: 

 

The VLC will automatically set itself from clock data in the VHX system. Simply connect the VLC to the VHX 
system and connect constant power to the VLC. When the key is turned on, it will adjust the clock hands to match 
the time data from the VHX system. 

 

NO CLOCK BIM MODULES 
 
If time data is not provided by any of the connected BIM expansion modules, the VHX system time is used to 
update the VLC time. Use the following steps to adjust the time if the VHX system time is being used. 

 

1.  Turn the key on to power on the VHX system. 
2.  Press and release the VHX switch until clock screen is displayed in VHX message center. (If the clock 

screen display has been disabled in VHX setup, it will need to be re-enabled to set the clock. It can again 
be disabled after the clock is set if so desired. See VHX operations manual for details.) 

3.  Press and hold the VHX switch to enter clock set mode. 
4.  Adjust time by pressing and releasing switch, save setting by holding switch.  
5.  VLC hands will adjust automatically to the time as it is changed.  

 

BIM MODULES WITH CLOCK 

 

Several BIM expansion modules can provide time data to the VHX system. The BIM-16-1 clock module and the 
GPS-50-2 compass module are two examples of this. If this type of module is being used and the clock channel is 
turned on, the VLC will update from this time instead of the VHX system time. To set the VLC clock when using a 
BIM time channel, use the following steps (see VHX operations manual or the BIM expansion module manual for 
more details on setting BIM channel time): 

 

1.  While holding VHX switch 1, turn the key on to turn on VHX system and enter setup. 
2.  Press and release switch 1 until the SETUP BIM option and press and hold switch to select it. 
3.  Press and release switch until SETUP option and press and hold to select it. 
4.  Press and release switch until the clock BIM channel is displayed. Press and hold to select. 
5.  Press and ho

ld to select “CLOCK” label. Message will show current time. Release switch. 

6.  Press and release to change time. Press and hold to set. 
7.  Exit setup mode by turning key off when completed. 

 

NOTE: The VLC may not track every change when setting but will update to new time with next key on. 

 
 

Содержание VLC Series

Страница 1: ...f a longer or shorter cable is desired a standard CAT 5 CAT 5E or CAT 6 PATCH cable of any length 7 feet or shorter may be used Do not use a cable longer than 7 feet or a crossover cable as these may cause improper operation or device damage NOTE Some VHX systems come with a VLC unit integrated into the kit These systems may already have the CAT 5 connection made inside the system Other systems ma...

Страница 2: ... by any of the connected BIM expansion modules the VHX system time is used to update the VLC time Use the following steps to adjust the time if the VHX system time is being used 1 Turn the key on to power on the VHX system 2 Press and release the VHX switch until clock screen is displayed in VHX message center If the clock screen display has been disabled in VHX setup it will need to be re enabled...

Страница 3: ...PLY Voltage Range BAT 8 to 18 V CURRENT DRAW BAT IGN off Approximately 0 5 mA IGN on 75 mA SERVICE AND REPAIR DAKOTA DIGITAL offers complete service and repair of its product line In addition technical consultation is available to help you work through any questions or problems you may be having installing one of our products Please read through the Troubleshooting Guide There you will find the so...

Страница 4: ...Clock will not adjust time to match VHX system time Battery wire not connected All 16 BIM channels are used and none of the channels is a clock No data is on the VHX communication line VHX connection not made Check that battery wire is connected to a constant 12V circuit Remove or disable an unused BIM channel If all the channels are to be used see Setting the clock when all 16 BIM channels in use...

Отзывы: