8.   “HI” (high temperature warning) will be displayed. Release green wire. 
9.  Power and release the green wire to adjust the high temperature warning point. 
10. Power and hold power to the green wire to store the high temperature warning point. 

 

POWER RED WIRE 

Connect the red wire from the main harness to accessory power from the ignition switch.   
Never connect this to a battery charger alone.  It needs to have a 12 volt battery connected to it.  Battery chargers 

have an unregulated voltage output that will cause the system to not operate properly.   

 

GROUND BLACK WIRE AND RING TERMINAL 

The black wire is the main ground for the gauge.  A poor ground connection can cause improper or erratic 

operation. Connect the ring terminal to one of the mounting studs after the clamp has been installed before the thumb nut 
is screwed on to secure the gauge. 

 

TEMPERATURE SENSOR GREY WIRE 

The gray wire connects to the temperature sensor.  DO NOT use Teflon tape on the sender threads as the sender 

grounds through the threads to a body ground. Using Teflon tape will prevent body grounding and will cause an error in the 
temperature reading. If the sender mounting prevents body grounding (i.e. mounting into plastic fittings) a grounding wire 
will need to be clamped to the body of the sender and connected to a good ground. 

 

FUNCTION WIRE GREEN WIRE 
 

The function wire (green wire) is used to change settings on the gauge as described above in the setup section. 

This is done by touching and removing the wire to +12V.   

 

NIGHT DIMMING BLUE WIRE 
 

Your display system has a dimming feature that reduces the display intensity.  Normally the system is at full 

brightness for daytime viewing. When the blue wire has 12 volts the display intensity will be reduced.  The blue wire can be 
connected to +12v through a switch to allow the dimming feature to be turned on or off. To have the system at full 
brightness all of the time, leave the blue wire disconnected.   
 
 
TROUBLESHOOTING GUIDE 

Problem 

Possible cause 

Solution 

Gauge will not light up. 

Red wire does not have power. 
Black wire is not getting a good ground. 
Gauge is damaged. 

Connect to a location that has power. 
Connect ground to a different location. 
Return gauge for repair. 

Gauge displays or flashes 

“EEE”.  

 

Gray wire is not connected properly.    
Sender has poor / no ground. 
 
Temperature is lower than range of 

sensor. 

Check connection from gray wire to sender. 
Check for good sender ground, remove any sealant 

tape for the threads of sender.  

This occurs at temperatures below freezing. Once in 

range, correct temperature will be displayed. 

Gauge displays or flashes         

“---“. 

Grey wire is shorted to ground. 
 
Temperature is above range of sender. 

Check grey wire for breaks in insulation or pinched 

areas.  

Take action to prevent further heating. If common 

problem, use higher temperature sender. 

Gauge always flashes. 

High warning point set too low. 

Adjust the high warning point using the setup menu.  

Gauge will not dim. 

Blue wire is not connected correctly. 

Check wiring. Blue wire should have 12 volts when 

dimming is desired. 

Gauge remains dim at all times. 

Blue wire is getting power all of the time. 

Connect blue wire to +12v through a switch or leave 

unconnected. 

Gauge will not go into the 

SETUP mode. 

Green wire is not powered at key on. 
 

Make sure to touch the green wire to a +12V source 

when turning on key.  

Check to make sure the point where the green wire 

is touched does have +12V using a voltmeter. 

Gauge displays “Er” followed by 

a number or letter. 

Some of the setup data has been lost or 

corrupted.  

Reset all settings in the SETUP menu to ensure they 

are correct. 

Gauge does not read correctly. 

Incorrect sender type selected. 

Select correct sender type using SETUP menu. 

 
 
 
 
 
 