background image

Manual # 650337 

 
 

Back View of Gauge

Dim Input (active high +12V)

BLUE wire

Switch Input (active high +12V)

GREEN wire

Optional momentary 
push button switch

Connect to main 

 chassis ground

+12V 

 

KEY ON POWER

Terminal not used on 

MCL-3K-VLT

+12V 

 

KEY ON POWER

           +12V 
 

KEY ON POWER

Optional toggle 
         switch

 
 

 

 
 

 
 
 
 
 
 
 
 
If you are installing multiple MCL-3K gauges you can tie the GREEN wires together and then to 

one switch.  The same is true for the BLUE wire, wire all of them to one switch.  

If you have a MCL-3K Tachometer, it will actually serve as the di

mming “switch”.  The BLUE wire 

on any of the MCL-3K Tachs will provide a +12V output for the dimming function.  The gauge has a light 
sensor behind the lens and when the ambient light is dim or low it will “turn on” the output and supply 
+12V to the BLUE wire.  You will not need to wire in a toggle switch if you have an MCL-3K tachometer 
and choose to wire it this way.   

Back View of Gauges

Dim Input (active high +12V)

BLUE wire

Switch Input (active high +12V)

GREEN wire

Optional momentary 
push button switch

+12V 

 

KEY ON POWER

           +12V 

 

KEY ON POWER

Optional toggle 

         switch

Continue wiring to other 

MCL-3K gauges

 

GAUGE SETUP  

The volt gauge setup only has options for setting a low voltage and high voltage warning point, 

and setup may be skipped if you are happy with the default settings.  The default settings are: 

Lo warn 

11.1 V   (adjustable range 9.6-12.6) 

 Hi warn 

15.4 V   (adjustable range 13.9-16.9) 

The GREEN switch input wire, in the two pin connector, is used to enter setup.  If you are only 

installing one or a couple Dakota Digital MCL-3K gauges set up may seem a little strange since they are 
designed to work as a set, however 

you’ll simply cycle through a few screens to get to the desired gauge.  

The table below shows what will be on the gauge with each button press, or tapping the GREEN wire 
high +12V. 

 

Speed 

Tach 

Oil psi  Oil temp 

Fuel 

Volt 

1

st

 





 





2

nd

 



  





3

rd

 





 





4

th

 

 



  

5

th

 



  





6

th

 



  





7

th

 



  





8

th

 



  





 

Connection shown with 
optional spade terminals  

Отзывы: