Dakota Digital HLY-3191 Скачать руководство пользователя страница 2

 

 

MAN# 650100A 

 
Setting the warning limits, sender setup, and update speed: 
 

The SND terminal is used to enter and change the warning settings.  You will need a wire connected to the 

SND terminal that can be momentarily grounded while you watch the gauge.  The headlight(s) should be off or the 
DIM terminal unhooked so that it does not interfere with the setup. 

1.  To enter the set mode, turn the k

ey on with the SND wire not grounded.  The gauge will display “SEt”.  

2. 

Ground the SND wire.  The gauge will display “PSI”.  (If you wait too long the gauge will exit the setup 
routine and you will need to repeat step #1). 

3.  Release the SND wire.  The gauge wi

ll display the current setup.  “150” is for 150psi, “400” is for 400psi, 

“75” is for 75psi, and “30” is for 30psi senders. 

4.  Each time you momentarily ground the SND wire the setup will change. 
5.  When the desired setup value is displayed, keep the SND wire grounded for about 2 seconds.  The gauge 

will display “ LO”. 

6.  Release the SND wire.  The gauge will display the current low warning pressure. 
7.  Each time you momentarily ground the SND wire the number will change. 
8.  When the desired low warning value is displayed, keep the SND wire grounded for about 2 seconds.  The 

gauge will display “HI”. 

9.  Release the SND wire.  The gauge will display the current high warning pressure. 
10.  Each time you momentarily ground the SND wire the number will change. 
11.  When the desired high warning value is displayed, keep the SND wire grounded for about 2 seconds.  The 

gauge will display “SPd”. 

12.  Release the SND wire.  The gauge will display the current update speed (slow or fast). 
13.  Each time you momentarily ground the SND wire the speed setting will change. 
14.  When the desired update speed is displayed, keep the SND wire grounded for about 2 seconds.  The 

gauge will display “--”. 

15.  Turn the key off. 

 
Troubleshooting guide. 

 

Problem   

 

Possible cause 

 

 

Solution   

 

 

 

 

 

 

Gauge will not light up 

PWR terminal does not have power. 

Connect to a location that has power. 

 

 

 

GND terminal does not have a good 

Connect to a different ground location. 

 

 

 

  ground. 

 

 

 

Gauge is damaged.  

 

Return gauge for service.  (see instructions) 

 

 

 

Gauge lights up, but does 

Loose connection on SND terminal. 

Reconnect wire. 

  not read correctly.   

Poor ground connection. 

 

Move ground to different location 

 

 

Gauge is sender setup is incorrect. 

See 

“Setting sender setup” in the manual. 

 

 

 

Voltage or wiring problem in the 

Check wiring harness for loose or damaged wires. 

 

 

 

  vehicle wiring harness. 

   

 

 

 

 

 

 

 

 

Gauge lights up, but displays  Gauge is damaged.  

 

Gauge must be returned for service.  (see instructions) 

  

“Er0”. 

 

 

 

 

 

 

 

 

 

 

 

 

 

   

Gauge lights up, but displays  SND terminal is shorted to ground. 

Check wire for damaged insulation.  Replace if necessary. 

  

“---”. 

 

 

Sender is damaged. 

 

Replace sender. 

 

 

 

 

 

 

Gauge lights up, but displays  Sender is not connected to gauge. 

Connect SND terminal on gauge to sender terminal. 

  

“EEE”.   

 

Wire between gauge and sender is 

Test and replace wire. 

 

 

 

  broken. 

 

 

 

Sender is not grounding properly. 

Sender grounds through it’s mounting threads.   Make sure the threads 
  are clean.  

Do Not Use Tape or Sealant

  

on Sender Threads. 

 

 

 

Sender is damaged. 

 

Replace sender. 

 

 

 

Gauge is damaged.  

 

Return gauge for service.  (see instructions) 

 

 

 

Gauge lights up, but displays  Gauge is sender setup needs to be 

See 

“Setting sender setup” in the manual. 

  

“Er4”. 

 

 

  reset. 

 

 

 

 

 

 

 

 

 

 

 

Gauge lights up, but displays  Gauge warning points need to be  

See “Setting the warning limits” in the manual. 

  

“Er5”. 

 

 

  reset. 

 

 

 

 

 

 

 

 

 

 

 

Gauge flashes constantly. 

Warning limits are not set properly. 

Reset warning limits. 

 

 

 

Pressure is too low or too high. 

Check filter and pump. 

 

 

 

 

 

Gauge will not dim.   

DIM terminal is not connected correctly. Check wiring connections. 

 

 

 

 

 

Gauge remains dim at all 

DIM terminal is getting power  all 

Connect DIM wire to location that only has power when the headlight(s) 

  times. 

 

 

  of the time. 

 

 

  are on. 

 

 

 

Battery is very low.   

 

Recharge or replace vehicle battery. 

 

 

 

Gauge is damaged.  

 

Return gauge for service.  (see instructions) 

 

 

 

 