Dakota Digital BIM-01-2-AEM Скачать руководство пользователя страница 3

MAN #650617 

HDX setup (Can also be completed using the Bluetooth app): 
Using speed from the BIM-01-2 

 

With ignition on. Press and hold both switches to enter SETUP. 

 

Press and release either switch until SPEED is selected. Press and hold either switch to enter SPEED menu. 

 

Press and release either switch until INPUT is displayed. Press and hold either switch to enter INPUT menu. 

 

Press and release either switch unit BIM is displayed. Press and hold either switch to select BIM. 

 
Using RPM from the BIM-01-2 

 

Press and hold both switches to enter SETUP. 

 

Press and release either switch until TACH is selected. Press and hold either switch to enter TACH menu. 

 

Press and release either switch until INPUT is displayed. Press and hold either switch to enter INPUT menu. 

 

Press and release either switch until CYLINDER is displayed. Press and hold either switch to select CYLINDER. 

 

Press and release either switch until BIM is displayed. Press and hold either switch to select BIM. 

 
Using engine temperature from the BIM-01-2 

 

Press and hold both switches to enter SETUP. 

 

Press and release either switch until WATER is selected. Press and hold either switch to enter WATER menu. 

 

Press and release either switch until INPUT is displayed. Press and hold either switch to enter INPUT menu. 

 

Press and release either switch until BIM is displayed. Press and hold either switch to select BIM. 

 
Using oil pressure from the BIM-01-2 (if available) 

 

Press and hold both switches to enter SETUP. 

 

Press and release either switch until OIL is selected. Press and hold either switch to enter OIL menu. 

 

Press and release either switch until INPUT is displayed. Press and hold either switch to enter INPUT menu. 

 

Press and release either switch until BIM is displayed. Press and hold either switch to select BIM. 

 
 
VFD/VHX/HDX wiring tip: 

When connecting to a VFD or VHX display system you can easily get power and ground from the control box R 
(FUEL+) and FUEL- terminals.  These terminals are normally not used.  Connect the BIM-xx-1 adapter harness RED wire to the 
R (FUEL+) terminal and connect the BIM-xx-1 adapter harness BLACK wire to the FUEL- terminal. 
 

Troubleshooting quick tips: 

While the BIM is operating, the dot in the upper left corner of the display will indicate the status.  On steady indicates it is 
powered up but not receiving any BIM bus activity.  Flashing indicates it is communicating on the BIM bus. 
If the display shows 



” then it is scanning to try and communicate with the AEM system bus but cannot get an answer. To see 

the sensor and channel status on the BIM display, press and hold the switch. The display will cycle through several screens.  
The first will show the bus type 

(“



” AEM). The next screens will indicate which (if any) extended data is available: “



” for 

intake/manifold 

temp, “



” for engine oil pressure, “



” for trans fluid temp. 

 
To set or change the ID number: 

The ID will not normally need to be changed. The fuel PSI and A/F ratio readings both use 

bus ID’s so if you have other BIM 

units connected along with this one there is a chance of ID conflicts. This can easily be resolved. If fuel PSI or A/F ratio is not 
showing up in the BIM setup menu on your system you may need to resolve an ID conflict. The following procedure will allow the 
BIM-01-2 to automatically select a new, unused ID. 

 

Hold the switch on BIM while turning the key on.  The BIM will show the current software code. 

 

Release the switch.   

 

Press and release 

the switch until “



” is shown on the display. 

 

Press and hold. 



” will be shown while the BIM is scanning the bus for other BIM units.   

 

When you see 



” shown on the display release the switch. 

 

The BIM unit will now go back to normal operation. 

 

***Intake/manifold air temp, Fuel PSI, boost and A/F ratio will be displayed in the group screens if activated through the displays>>group set menu 
setup. 

Содержание BIM-01-2-AEM

Страница 1: ...et enabled devices These kits include Infinity ECU Series 2 EMS or EMS 4 The module is connected to the AEM device through the 4 pin AEMnet connection plug on the main harness There are two interface I O ports on the module Either one can be connected to the gauge system or to another module allowing several units to be daisy chained together Do not connect the I O port to anything other than a Da...

Страница 2: ... SPEED Press and hold SW1 The message display should show SENDER Release SW1 Press and release SW1 until BUS is displayed Press and hold SW1 until DONE is displayed Using RPM from the BIM 01 2 Hold the SW1 switch from the gauge system control box while turning the key on The message display should show SETUP Release SW1 Press and release SW1 until TACH is displayed Press and hold SW1 The message d...

Страница 3: ... tip When connecting to a VFD or VHX display system you can easily get power and ground from the control box RESERVED FUEL and FUEL terminals These terminals are normally not used Connect the BIM xx 1 adapter harness RED wire to the RESERVED FUEL terminal and connect the BIM xx 1 adapter harness BLACK wire to the FUEL terminal Troubleshooting quick tips While the BIM is operating the dot in the up...

Страница 4: ...the RMA number on the package and include a complete description of the problem with RMA number your full name and address street address preferred and a telephone number where you can be reached during the day Any returns for warranty work must include a copy of the dated sales receipt from your place of purchase Send no money We will bill you after repair Dakota Digital Limited Lifetime Warranty...

Отзывы: