background image

M

803927

Owner’s Manual

Instructions for Assembly, Testing, Operation, Servicing, and Storage

12V Diaphragm Pump

: For use with non-potable liquids such as water-based

agricultural pesticides and other liquids**

WARNING

READ and UNDERSTAND the Owner’s Manual completely before using this pump

Assemble, test, and use only in accordance with the Owner’s Manual instructions.

READ and FOLLOW chemical safety instructions.

Pesticides are hazardous chemicals.

KNOW emergency procedures BEFORE handling chemicals.

Pump leaks, bodily chemical 

contact, poisoning, and spills require immediate response.

AVOID inhaling, ingesting, or coming into contact with any chemicals.

WEAR personal protective gear when operating, cleaning, and servicing the pump.

KEEP pump and spray materials away from children and pets.

Pesticides are especially 

toxic to them.

DO NOT TURN ON POWER to pump until ready to spray

in order to avoid unintentional 

spray release.

ALWAYS 

keep a fire extinguisher rated “ABC” nearby.

Improper use of the pump or handling of chemicals could result in serious injury or 
illness to the operator or nearby persons/animals, or could cause damage to the 
environment.

**This pump is recommended for use in spraying non-flammable liquids such as pesticides, water 

for plants/trees or dust control, and water-based non-flammable sealants or stains for outdoor wood 
surfaces. The pump will be damaged and warranty voided if used to apply bleach, chlorine, ice 
control chemicals, or any petroleum based product (gasoline, diesel, kerosene, oil). The pump should 
not be used to transfer any product intended for human consumption. WE RECOMMEND THAT 
THE PUMP NOT BE USED FOR OTHER PURPOSES ONCE IT HAS BEEN USED FOR
SPRAYING PESTICIDES. Any chemical will leave some residual in the pump components, even 
after the pump has been properly cleaned. These residual chemicals can have unexpected effects on 
future uses. For example, spraying water or other liquids that are contaminated with residual 
pesticide may result in unforeseen hazards to plant or animal life. This pump should not be used by 
people with reduced physical, sensory or mental capabilities or lack of experience and knowledge.

Any Questions, Comments, Problems, or Parts Orders

Call

 

Daken

 

Product

 

Support

 1800 648 384

ITEM 

NUMBER:

 

D3BP

,

 

D5BP

,

 

D8BP

,

 

D11BP

,

 

D15BP

,

 

D20BP

,

 

D26BP

Содержание D11BP

Страница 1: ...s injury or illness to the operator or nearby persons animals or could cause damage to the environment This pump is recommended for use in spraying non flammable liquids such as pesticides water for plants trees or dust control and water based non flammable sealants or stains for outdoor wood surfaces The pump will be damaged and warranty voided if used to apply bleach chlorine ice control chemica...

Страница 2: ...Hazard Signal Word Definitions 2 ...

Страница 3: ...Four Check and test completed assembly 11 Operation Important Safety Information Operation 12 General Chemical Safety Chemical Applicator Safety Chemical Accident Procedures Preparing the Pump for Each Use 16 Using the Pump Step One Assess wind conditions and clear work area 17 Step Two Operate the pump 17 Step Three Clean pump and decontaminate after use 19 Storage 20 Preparing for storage Removi...

Страница 4: ...ized form or for use with fumigants In addition to spraying pesticides this pump may be used to spray other non flammable liquids Example uses include watering plants trees or spraying water for dust control or applying water based non flammable sealant or stain to outdoor wood surfaces WE RECOMMEND THAT THE PUMP NOT BE USED FOR OTHER PURPOSES ONCE IT HAS ALREADY BEEN USED FOR SPRAYING PESTICIDES ...

Страница 5: ...l label WEAR protective clothing eye protection and chemical resistant gloves when operating the pump Wear additional protective gear such as facemask or apron as recommended on the chemical label EXERCISE EXTRA CAUTION around children and pets Pesticides are especially toxic to them Keep pump and spray materials away from them at all times DO NOT MIX OR POUR chemicals in an enclosed unventilated ...

Страница 6: ... Personal contamination can occur when chemicals splash spill or spray directly onto a person 1 Immediately follow First Aid instructions on chemical label General procedures can include a Eyes immediately flush with water b Skin wash all contaminated skin surfaces with soap and water c Clothing remove contaminated clothing Dispose of heavily contaminated clothing per chemical label instructions 2...

Страница 7: ...9143001507 D5BP 9349143001514 D8BP 9349143001521 D11BP 9349143001538 D15BP 9349143001545 D20BP 9349143001552 D26BP 9349143001569 Daken 3 8 LPM 1 0 GPM Pump 7 WARNING DO NOT PUMP FLAMMABLE FLUIDS DO NOT USE PUMP IN AN EXPLOSIVE ENVIRONMENT READ AND UNDERSTAND THE OWNER S MANUAL COMPLETELY BEFORE USING RELIEVE SYSTEM PRESSURE BEFORE PERFORMING Daken 5 7 LPM Pump Daken 8 3 LPM 2 2 GPM Pump Daken 11 3...

Страница 8: ... Inside diameter 3 4 19mm Inside diameter D3BP 3 4 Quick Connect 3 8 9 5mm Inside diameter 3 8 9 5mm Inside diameter NOTE Daken does not recommend the use of metal fittings or rigid pipe to plumb the inlet outlet ports Standard plastic threaded fittings are available by calling Daken Product Support at 1800 648 384 In some cases the ports may require a suitable thread sealer applied sparingly DO N...

Страница 9: ... with water and neutralize with baking soda 2 Electrical requirements The pump should be on a dedicated individual circuit controlled with a double pole switch UL CSA certified rated at or above the fuse ampere indicated by the pump motor label Depending on distance of the power source from the pump and ampere load on the circuit wire may need to be heavier than indicated by the chart The pump is ...

Страница 10: ...not in a vehicle WARNING Always connect in this sequence to avoid possible shock D3BP D5BP D8BP D11BP D15BP D20BP Positive red wire Negative black wire D26BP Positive red Negative black 4 Disconnect after use AFTER EACH USE disconnect power to the pump using the following procedure a Disconnect the vehicle battery ground wire b Disconnect the pump s black wire from the negative terminal of the bat...

Страница 11: ...ver modify the pump design 1 Check assembly Check assembly to assure the pump is properly assembled and in safe working condition 2 Test with water Test the system for leaks with water a Fill the tank with water b The pump is an on demand pump When turned on the pump will prime itself then turn off once reaching pressure When the flow continues the pump will automatically re start c Check for leak...

Страница 12: ... or coming into contact with the chemical Personal protective equipment ALWAYS wear protective clothing eye protection and chemical resistant gloves when operating and cleaning the pump Wear additional protective gear such as facemask or apron as recommended on the chemical label Children pets Pesticides can be especially toxic to children and animals ALWAYS exercise extra caution around children ...

Страница 13: ...cal manufacturer Excess pesticide can be dangerous to humans damage desirable plants and contaminate soil and water sources Children pets ALWAYS exercise extra caution when spraying near areas accessible to children and pets Eating smoking DO NOT eat drink smoke rub your eyes or touch any part of your bare skin while handling chemicals and spraying Heat flames DO NOT spray near open flames or sour...

Страница 14: ... water or follow directions as specified on the chemical label c Clothing remove contaminated clothing immediately Dispose of heavily contaminated clothing per the instructions on the chemical label for safe chemical container disposal 2 Seek medical advice if instructed on the label or if the victim experiences symptoms of harmful effects such as burning swelling nausea chest pain difficulty brea...

Страница 15: ...aterials like ground corncobs or pet litter should be spread on the spill area to soak up the pesticide The contaminated material should then shoveled into a leak proof container Do not flush the spill area with water until you receive advice as directed below 4 Seek additional advice from the chemical manufacturer and your state s pesticide regulatory agency regarding decontamination of the spill...

Страница 16: ...in a safety hazard or poor operation of the sprayer 1 Ensure clean system Ensure the pump has been thoroughly flushed and drained of all residual chemicals from prior uses 2 Inspect repair Inspect and test the sprayer thoroughly a Inspect hoses lines for exposed mesh and holes Replace all worn or damaged hoses lines b Inspect fittings for cracks and leaks Replace all damaged fittings with original...

Страница 17: ...rea Clear the work area of all bystanders and pets Restrict access by the public for the period recommended on chemical label Step Two Operate the pump WARNING ALWAYS wear personal protective equipment as directed on the chemical label when spraying Long pants and sleeves chemical resistant gloves and eye protection are strongly recommended Additional protective gear may be required depending on t...

Страница 18: ...wer to the pump b Relieve system pressure 6 Discontinue use if clogged or inoperative If the pump becomes clogged or inoperative during use discontinue use immediately DO NOT attempt to service while chemicals are in the pump and power is connected Return to service area to review instructions for troubleshooting before attempting to service CAUTION DO NOT operate the pump at pressures which cause...

Страница 19: ...cide is to be stored for future use Store all unused pesticide in its original or a suitably marked container in a secure location out of the reach of children animals b If remaining pesticide is to be disposed Properly dispose of the remaining chemical and its container per the chemical manufacturer s recommendation and according to local hazardous waste disposal regulations 3 Flush pump Flush th...

Страница 20: ...Pour RV antifreeze into the pump system Note RV antifreeze is non toxic and biodegradable and generally safer for the environment than automotive antifreeze 2 Spray briefly Turn on the pump and run the pump system briefly until fluid sprays Removing from storage 1 Drain Drain the antifreeze left in the pump system into a suitable container 2 Flush with water Fill the pump system with fresh water a...

Страница 21: ...l protective equipment as directed on the chemical label while servicing your pump 2 Review troubleshoot ing table Review the Troubleshooting Table below for the type of problem you are experiencing However DO NOT attempt to repair until the steps listed below are followed 3 Empty and flush Empty the pump system and flush the pump with water as directed in the section Operation Step Three In order...

Страница 22: ... fittings Replace cracked fittings Worn diaphragm Replace diaphragm assembly Worn valves Replace valve plate assembly Inlet Outlet tube restriction Remove restriction Incorrect voltage Check voltage 10 Clogged intake valves Remove obstruction Clogged intake tube Remove obstruction Pump leaks Loose fasteners Tighten fasteners Pump seals degraded Replace pump head assembly Leak in diaphragm Replace ...

Страница 23: ...8 384 Model Number Electrical connection Maximum amp draw Maximum flow Maximum pressure Ports Overall dimensions Weight D3BP 12 VDC 4 Amps 1 0 GPM 3 8 LPM 40 PSI 2 8 bar 3 4 Quick connect 7 3 x 3 9 x 3 184mm x 100mm x 78mm 2 lbs 0 9 kg D8BP 12 VDC 8 Amps 2 2 GPM 8 3 LPM 70 PSI 4 8 bar 3 4 Quick connect 9 x 4 x 4 230mm x 102mm x 102mm 4 9 lbs 2 22 kg D11BP 12 VDC 10 Amps 3 0 GPM 11 4 LPM 60 PSI 4 1...

Страница 24: ...nect fittings are compatible with D3BP D8BP D11BP D15BP D20BP and D26BP Part Description 787212 Quick Connect x 3 8 Hose barb elbow 787213 Quick Connect x 1 2 Hose barb elbow 787215 Quick Connect x 1 2 Hose barb 50 elbow 787216 Quick Connect x 3 8 Hose barb elbow x 1 4 FNPT elbow Quick Connect x 3 8 Hose barb Part 787208 24 Quick Connect x 1 2 Hose barb Part 787209 Quick Connect x 3 4 Hose barb Pa...

Страница 25: ...1 2 791634 Base plate assembly 1 3 790576 Diaphragm assembly 1 4 790584 Valve plate assembly 1 5 790589 Upper housing assembly 1 6 791635 Pressure switch assembly 1 7 788429 Quick connect clip 2 8 A2681042 Complete pump head assembly 1 N A 791415 Replacement fuse 1 787380 25 ...

Страница 26: ...bly 1 2 800428 Base plate assembly 1 3 794988 Diaphragm assembly 1 4 794989 Valve plate assembly 1 5 787015 Quick connect clip 2 6 787011 Upper housing assembly 1 7 786953 Pressure switch assembly 1 8 A2682272 Complete pump head assembly 1 N A 787381 Replacement fuse 1 26 ...

Страница 27: ...l 1 3 788017 Diaphragm assembly D11BP 1 788018 D15BP 788019 D20BP 4 788015 Valve plate assembly All 1 5 787012 Upper housing assembly All 1 6 788689 Pressure switch assembly All 1 7 787015 Quick connect clip All 2 8 A2683062 Pump head assembly D11BP 1 A2684062 D15BP A2685562 D20BP N A 787381 Replacement fuse D11BP 1 D11BP 1 791416 Replacement fuse D20BP 1 27 ...

Страница 28: ...1 2 790016 Base plate assembly 1 3 788019 Diaphragm assembly 1 4 788015 Valve plate assembly 1 5 787012 Upper housing assembly 1 6 788689 Pressure switch assembly 1 7 789252 Relay cover 1 8 788929 Relay 1 9 787015 Quick connect clip 2 10 A2687062 Complete pump head assembly 1 N A 791419 Replacement fuse 1 28 ...

Страница 29: ...36 Motor assembly 1 2 800428 Base plate assembly 1 3 797013 Diaphragm assembly 1 4 798397 Valve plate assembly 1 5 797105 Upper housing assembly 1 6 797407 Pressure switch assembly 1 7 A26815152 Complete pump head assembly 1 N A 787381 Replacement fuse 1 29 ...

Страница 30: ...s to be replaced or repaired is the sole decision of Daken NOTE Some services performed by parties other than Daken may void warranty This warranty covers parts only It will not provide for replacement of complete products due to defective parts Components not manufactured by Daken are guaranteed by their manufacturer and can be serviced at factory authorized locations near you Any costs incurred ...

Страница 31: ... 648 384 or email sales clarkfarmequipment com au Operating 8 30am 5pm Monday to Friday Product Technical Support Call us on Toll Free 1800 817 366 or email support clarkfarmequipment com au Operating 8 30am 5pm Monday to Friday Limited hours on weekends ...

Отзывы: