WIRING INSTRUCTIONS 

 

 

WARNING:

 

A licensed qualified electrician that follows all state and local laws must 

wire and install electrics on this press.

 

 

110 Volt 
 

 WARNING: Machine must have a designated 30 amp drop for 110 volts. This press 

will not operate correctly without 30 amps. 
 

For 110 volts this machine is ready to plug in. The machine can be wired 220-volt single phase. 
Always follow the wiring diagram provided in the moor cover when converting to 220-volt single 
phase. A cord and plug that is rated for a specific voltage and amperage must be used. This 
rating can be found on the motor. 
 

220 Volt Single Phase

  

 
The press new is shipped out as a 110-volt machine. If wiring must be changed to suit 220-volt 
single phase. 
 

1.  The leads on the motor must be changed to fit 220-volt, 17.2 amps, follow the diagram on 

the motor. 

2.  Install plug and wire that fits the rating on the motor, the plug and wire must be rated for 

the voltage and amperage listed on the motor.  

 
 
 

OPERATION 

 

BEFORE FIRST TIME OPERATION 

 

1.  Make sure the reservoir is filled with 3 gallons of Mobil DTE 24 hydraulic fluid or 

equivalent. 

2. 

Turn the on/off power (toggle) switch to the “on” position (up). 

3.  Move the control lever down, this will advance the ram in the downward position. 

4.  Release the control lever and the ram will stop all movement. 

5.  Move the control lever to the up position and the ram with move up. 

6.  When the press is new be sure to move the ram up and down to work out any air that 

may be in the system. 

 

WARNING: When using the control lever in pressing operations or to return the ram 

stop applying pressure once the handle reaches its positive stop. Applying additional 
force on the lever does not increase ram speed and will lead to premature damage of the 
valve. 

Содержание Force 50DA

Страница 1: ...0 846 3253 www dakecorp com customerservice dakecorp com DAKE SINGLE PHASE DURA PRESS Force 50DA INSTRUCTIONAL MANUAL WARNING Read and understand all instructions and responsibilities before operating...

Страница 2: ...D POLICY 4 SAFEGUARDING THE POINT OF OPERATION 5 SPECIFICATIONS 6 SAFETY 7 SET UP 9 PRESS PLACEMENT 9 FILLING THE PRESS WILL OIL 9 WIRING INSTRUCTIONS 10 OPERATION 10 BEFORE FIRST TIME OPERATION 10 MA...

Страница 3: ...he repair work completed The standard limited warranty includes repair of the defective component part at no cost to the end user Warranty Process Subject to the conditions hereinafter set forth the m...

Страница 4: ...llation or failure to operate or maintain the unit in accordance with the printed instructions provided c Defects or malfunctions resulting from abuse accident neglect or damage outside of prepaid fre...

Страница 5: ...by Customer Service a representative will supply a Return Material Authorization RMA number The returned item must have the provided RMA number clearly marked on the outside packaging Any item receive...

Страница 6: ...on safeguarding system The standard also discusses additional responsibilities of the employer Some of the key responsibilities are The employer is responsible for the safety use and care of the hydra...

Страница 7: ...16 Pressing Speed 11 ipm Width between uprights 44 Max ram to table 41 3 4 Height 94 Base 55 x 36 Weight 3 450 lbs In the space provided record the serial number and model number of the machine This...

Страница 8: ...ges in this manual and on your press safety labels Keep safety labels in good condition Replace missing or damaged safety labels Do not alter this press from its original design Do not make repairs or...

Страница 9: ...Dake Corporation 724 Robbins Road Grand Haven MI 49417 www dakecorp com 909250 8 REV052019 Label Placement View...

Страница 10: ...from any other objects or machines Press should be placed on level floor with base angles touching the floor at all points Use shims where necessary FILLING THE PRESS WILL OIL Fill the reservoir with...

Страница 11: ...he leads on the motor must be changed to fit 220 volt 17 2 amps follow the diagram on the motor 2 Install plug and wire that fits the rating on the motor the plug and wire must be rated for the voltag...

Страница 12: ...ess well oiled for easier operation Also keep a light film of oil over the entire surface of the ram to prevent rust HYDRAULIC LINES AND FITTINGS If there is ever any maintenance done with the hydraul...

Страница 13: ...Dake Corporation 724 Robbins Road Grand Haven MI 49417 www dakecorp com 909250 12 REV052019 ELECTRIC SCHEMATIC...

Страница 14: ...Dake Corporation 724 Robbins Road Grand Haven MI 49417 www dakecorp com 909250 13 REV052019 HYDRAULIC SCHEMATIC...

Страница 15: ...Dake Corporation 724 Robbins Road Grand Haven MI 49417 www dakecorp com 909250 14 REV052019 EXPLODED VIEW PARTS LIST...

Страница 16: ...Dake Corporation 724 Robbins Road Grand Haven MI 49417 www dakecorp com 909250 15 REV052019...

Страница 17: ...19 Please contact factory for current prices ORDERING INFORMATION Parts are available for direct purchase from Dake or through a distributor When placing a parts order you will need to provide the par...

Отзывы: