Electrical Connection
Only a certified electrician that follows local and state laws is authorized to perform any
type of electrical connection on this press. The electrical power supply voltage must be made
in compliance with local and state laws.
−
This machine is dual voltage 220V 3-phase / 440V 3-phase. The amp rating for voltages are in
the table below.
Voltage
Amp Rating
220V, 3-phase
6.8 amps
440V, 3-phase
3.4 amps
•
For proper operation it is necessary to ensure constant voltage and must not exceed or be
lower than 5% of the rated value.
•
Before making any electrical connections, confirm the voltage rating of the machine. There is a
black plastic box mounted on top of the reservoir with the rated valve.
•
Be sure there is no power to the machine before checking the following
connections. It may be necessary to lock out the machine for proper power
disconnection.
•
Remove the two mounting screws that hold this box in place. Under this box you will see one
of the following possibilities shown below. After confirming or changing the voltage to the
correct voltage mount the cover with the two screws. Now open the electrical panel on the
transformer to check if it is set to the correct output voltage.
•
Any damage caused by a faulty electrical connection is not cover by warranty.