background image

INSTALLATION AND MAINTENANCE MANUAL

Serie

PORTABLE

Edition

R00

Models

ADP-

12

FX-A3

 

ADP-

12

F

/CX

-A3

Содержание PORTABLE Series

Страница 1: ...INSTALLATION AND MAINTENANCE MANUAL Serie PORTABLE Edition R00 Models ADP 12FX A3 ADP 12F CX A3...

Страница 2: ...roughout the EU To prevent possible harm to the environment or human health from un controlled waste disposal recycle it responsibly to promote the sustainable reuse of mate rial resources To return y...

Страница 3: ...components that produced by other manufacturers 6 After verification the problem or dispute is caused by the quality specification or majeure 7 The damage is caused by natural calamities bad using en...

Страница 4: ...e appliance read the service manual first Appliance filled with flammable gas R290 Appliance shall be installed operated and stored in a room with a floor area larger The appliance shall be stored in...

Страница 5: ...nto the air conditioner Do not repair or disassemble the air conditioner by yourself Do not put or hang dripping objects above the air conditioner Keep children from playing or climbing on the air con...

Страница 6: ...onment During operation close doors and windows to improve cooling effect Please keep air inlet and air outlet clean no obstacles to avoid noise and vibration Please put the air conditioner at smooth...

Страница 7: ...4 Castor 5 Plug of power cord Wire fixing hook 7 Filter 8 Air inlet 9 Joint A 10 Heat discharge pipe 11 Joint B C 12 Remote controller hook 6 Part s Name Installation accessories can t be discarded N...

Страница 8: ...er will give out a sound Meanwhile corresponding indicator on control panel will be bright Under OFF status dual 8 nixie tube on control panel won t display Under ON status dual 8 nixie tube on contro...

Страница 9: ...eed will circulate as low speed medium speed high speed auto fan low speed Fan button 4 Timer 5 Press timer button to enter into timer setting mode Under this mode press or button to adjust the timer...

Страница 10: ...tion time Condensation may form on the louvers Do not adjust the horizontal louvers to the lowest or the highest position in the 2 Left right air flow direction Hold the vertical louver as shown in th...

Страница 11: ...gnal Make sure nothing such as curtains blocks the The signal effective distance is 8m Do not expose the receiver window to direct sunlight Use of certain fluorescent lamp in the same room Do not leav...

Страница 12: ...de Cool mode Dry mode Fan mode Heat mode TIMER ON TIMER OFF 1 On Off button 2 Mode button button 4 Swing button 5 Fan button 6 Sleep button 7 Timer button 8 Health button 9 WiFi button Light function...

Страница 13: ...Heat Under this mode air conditioner operates under heating mode Press Fan Speed button can adjust the fan speed Cooling only unit won t receive heating mode signal If setting heat mode with remote co...

Страница 14: ...ess button or button to adjust timer setting time will change quickly if holding or button Time setting range is 0 5 24hours Press this button again to confirm timer setting and the characters of HOUR...

Страница 15: ...ns simultaneously to set the lamp on or off and send the code After being energized the lamp is defaulted on 1 Press the back side of remote controller marked the cover of battery box along the arrow...

Страница 16: ...dust on the surface of outer case please use soft towel to wipe it If the outer case is very dirty such as grease please use neutral abluent to wipe it a Press the clasp as shown in the fig and then...

Страница 17: ...t and sundries on the air conditioner 4 Eliminate accumulated water in chassis refer to the section of Drainage way for details 5 Check whether window bracket is damaged or not If yes please contact d...

Страница 18: ...losed Is plug loose Whether the air switch is trip ped off or fuse is burnt Is there s malfunction for the circuit Whether the unit is restarted up after stopping immediately Wait after power recovery...

Страница 19: ...cold air air conditioner will delay for a while to be started up which is the normal phenomenon It s the normal phenomenon Air conditioner is defrosting will resume operation There s off the room such...

Страница 20: ...in the unit ERROR CODE and high humidity environment if ambient temperature is too high power off the unit and then energize it for operation after the ambient temperature drops to 35 below blocked by...

Страница 21: ...y Safety precaution 1 Must follow the electric safety regulations when installing the unit 2 According to the local safety regulations use qualified power supply circuit 3 For appliances with type Y a...

Страница 22: ...in connector heat discharge pipe Optional Window kit Bracket Rain guard Insect guard net Window panel Exhaust cover Adjustment panel Extension panel screw remote control pipe hoop pipe clip rubber plu...

Страница 23: ...re Hook Assemble the wire hook at the back of the unit with screws the direction of wire Wind the power cord around the wire hook direction of wire hook is upward direction of wire hook is downward sc...

Страница 24: ...t NOTICE When using the continuous drainage option from the bottom hole install drainage pipe as follow before using otherwise poor drainage will affect normal operation of the unit There are 2 ways t...

Страница 25: ...ounds and H8 is displayed to remind user to discharge water Move the unit to a suitable place for discharging water do not tilt the unit and keep it horizontal during moving Take the drainage pipe fro...

Страница 26: ...hole place portable on a level surface and make sure garden hose is clear of any obstructions and is directed downward Placing portable on an uneven surface or improper hose installation may result i...

Страница 27: ...guards to the insect guard net Insert all three projections on each rain guard into the holes in the insect guard net 2 Attach the guard combined above to the window panel Push the insect guard net fi...

Страница 28: ...1 Open the window sash and place the window panel on the window sill 2 Slide the adjustment panel to fit the window frame width 3 Secure the window panel to the sill with screws Inner width of the win...

Страница 29: ...e the window sash securely against the Window panel 7 Attach the bracket with a screw Recommended Please lay a tabular material underneath the window panel in case you could not attach the rain guard...

Страница 30: ...sect guard net Insert all three projections on each rain guard into the holes in the insect guard net 2 Attach the guard combined above to the window panel Push the insect guard net firmly to ensure t...

Страница 31: ...he window frame 2 Slide the adjustment panel to fit the window frame height 3 Secure the window panel to the window frame with screws Inner height of the window 38 5 980mm 59 1500mm Use the window pan...

Страница 32: ...a tabular material underneath the window panel in case you could not attach the rain guard or the window adapter properly due to the deep window sill Bracket Installation in a sliding sash window Opt...

Страница 33: ...harge pipe clockwise clockwise joint A joint B C heat discharge pipe 2 Insert joint A of heat discharge pipe the side with TOP is upwards into the groove until you hear a sound 3 Lead the exhaust hose...

Страница 34: ...arge pipe correct correct correct wrong The length of the heat discharge pipe is less than 1m It is recommended to use it with shortest length the pipe or connect it with other When installing heat di...

Страница 35: ...t discharge pipe 2 Remove joint B C from 1 Remove joint A Press the clasp and lift joint A upwards to outdoors remove it upwards clasp disassemble joint A would easily cause malfunction Installation a...

Страница 36: ...nstallation and Disassembly of Heat Discharge Pipe 33 PUSH PUSH Operation Test Put through the power supply and then press ON OFF button on remote contro ller to start the unit Press mode button to se...

Страница 37: ...K SA The Electric schematic diagram are subject to change without notice Please refer to which one on the unit Electric Schematic Diagram 34 R M OUTTUBE RT3 TUBE RT2 RT1 BOARD DISPLAY REC RECEIVER BOA...

Страница 38: ...potentially toxic or flammable atmospheres Ensure that the leak detection equipment being used is suitable for use with all applicable refrigerants i e non sparking adequately sealed or intrinsically...

Страница 39: ...all include initial safety checks and component inspection procedures If a fault exists that could compromise safety then no electrical supply shall be connected to the circuit until it is satisfactor...

Страница 40: ...inguished remove refrigerant purge the circuit with inert gas evacuate purge again with inert gas open the circuit by cutting or brazing If a leakage of refrigerant is found which requires brazing all...

Страница 41: ...mpletion of charging but prior to commissioning A follow up leak test shall be carried out prior to leaving the site Ensure that contamination of different refrigerants does not occur when using charg...

Страница 42: ...order Empty recovery cylinders are evacuated and if possible cooled before recovery occurs The recovery equipment shall be in good working order with a set of instructions concerning the equipment tha...

Страница 43: ...Eurofred S A Marqu s de Sentmenat 97 08029 Barcelona www eurofred es...