Emergency Operation 

Emergency Operation 

When the remote controller is lost or damaged,  
please use the manual switch on the main unit.  
In that case, the unit will operate in AUTO mode   
and the temperature setting or fan speed can not 
be changed.
The manual switch can be operated as below:   

Manual switch  

Turn on the unit: Press AUTO/STOP button to 
enter AUTO mode.   

●  

The microprocessor will select the mode (COOL, 
HEAT, FAN) automatically according to the room 
temperature for reaching comfortable effect.  

Turn off the unit: Press the AUTO/STOP button to 
switch off the unit.   

●  

The operation mode is shown in the following table.

  Mode  

      Model  

Temperature setting

Airflow rate  

AUTO              COOLING               25 ºC (COOL,FAN) 

AUTO  

This switch is to be applied when the remote controller is missing.

12

 -  

AUTO              HEAT PUMP           20 ºC (HEAT) 

AUTO  

AUTO              HEAT PUMP           25 ºC (COOL,FAN) 

AUTO  

Содержание HS-18UIEK

Страница 1: ...u for choosing Residential Air Conditioners please read this owner s manual carefully before operation and retain it for future reference Owner s Manual Residential Air Conditioners MODEL HS 18UIEK HO...

Страница 2: ...tands for the items should be forbidden The products in this manual may be different with the real one according to different models some models have displayer and some models without displayer the po...

Страница 3: ...se it may cause electric shock or fire Otherwise it may cause electric shock Otherwise it may cause fire due to overheating of power cord Before cleaning the air conditioner please turn off the air co...

Страница 4: ...outlet Do not keep windows and doors open for a long time during operation Keep combustible materials at least 1m away from the units It will result in insufficient performance It will result in insuf...

Страница 5: ...nds or objects into the air inlet or outlet Do not expose animals orplants directly to the air flow It may cause an accident It may have a detrimental effect on them Do not expose yourself to cold air...

Страница 6: ...g heating efficiency The air conditioner may stop operation during auto defrosting operation During auto defrosting the fan motors of indoor unit and outdoor unit will stop During defrosting the indoo...

Страница 7: ...rheat Setting temperature at a moderate level helps energy saving Cover windows with a blind or a curtain Blocking sunlight and air from outdoors is favorable for cooling heating Clean air filters onc...

Страница 8: ...t Air in 2 6 5 Air out 3 4 The icons displayed 1 Cool Dry Heat Power Set temp 2 Front panel Outdoor unit Air in 7 8 Air out 6 1 Remote control 3 Filter 4 Guide louver 5 Wall pipe 6 Bind tape 7 Connect...

Страница 9: ...can be set up signal blink and display Within 5 seconds the value can be adjusted by pressing or button if continuously press this button for 2 seconds above in every 0 5 seconds the value on ten plac...

Страница 10: ...ure can be set up continuously press this button and hold for two seconds the re lative contents can quickly change until unhold this button and send the order that the C F signal will be displayed al...

Страница 11: ...e one place of minute then the one place is constant ten num bers change in the tens place of minute at 2 5 seconds speed and carry During 5s blink press the Timer On button the timer setting succeeds...

Страница 12: ...utton can realize the ON and OFF of TURBO function Introduction for special function About X FAN function This function indicates that moisture on evaporator of indoor unit will be blowed after the un...

Страница 13: ...If remote controller is under off status press mode button and X FAN button simultaneously in order to enter or cancel this new function If the unit is under defrost mode dual eight position on remote...

Страница 14: ...unit Press AUTO STOP button to enter AUTO mode The microprocessor will select the mode COOL HEAT FAN automatically according to the room temperature for reaching comfortable effect Turn off the unit P...

Страница 15: ...to water so as to protect microprocessor components and circuit diagram on the front panel Cleaning the Air Filter every 3 months Note Do not touch the fin of indoor unit during cleaning to avoid pers...

Страница 16: ...eplaced 3 Check if the installation stand of the outdoor unit is damaged If damaged consult the technicians Maintenance after Use 1 Switch off the power supply 2 Clean the filters and bodies of indoor...

Страница 17: ...ay be emitted from the indoor unit This is the result of room smells such as furniture tobacco ect which have been taken into the air conditioner Consult authorized service center for cleaning if the...

Страница 18: ...case pull the plug out and reinsert it Remote controller is not available Is the remote controller within its operating range or obstructed Check the condition of the batte ries and replace them if ne...

Страница 19: ...es in order to avoid condensate being vaporised again If the unit operates at high humidity for a long time moisture will be generated on the air outlet grill and then drip off Moisture on air outlet...

Страница 20: ...that the plug is accessible 7 The temperature of refrigerant line will be high please keep the interconnection cable away from the copper tube 8 The instructions shall state the substance of the foll...

Страница 21: ...lace but do not expose the unit to direct sunlight or strong wind 6 Make sure that the outdoor unit is installed in accordance with the installation instructions and is convenient for maintenance and...

Страница 22: ...al criterion 4 The power must have reliable earthing terminal Please do not connect the earthing wire with the following 1 Water pipe 2 Gas 3 Contamination pipe 4 Other place that professional personn...

Страница 23: ...Above Above Air outlet side Space to the floor The dimensions of the space necessary for proper installation of the unit include the minimum permissi ble distances to adjacent parts Space to the obstr...

Страница 24: ...UNIT 24K UNIT 694 52 194 298 256 55 55 45 82 160 14 940 Fig 5 139 184 685 157 315 70 70 36 45 65 90 Drill Piping Hole Indoor Outdoor 1 Slant the piping hole 55 70 on the wall slightly downward to the...

Страница 25: ...6 3 Make the power connection cord pass through the hole at the back of indoor unit 4 Reinstall the cord anchorage and wiring cover 5 Reinstall the front panel Wiring Cover 18 24K Heat pump type N 1 2...

Страница 26: ...side piping Tailing 2 Gas side piping insulation Tailing 1 Liquid side Piping insulation Fig 7 Finally wrap it with tape Water drainage pipe Left rear Right Right rear Fig 8 Fixing hook Mounting baord...

Страница 27: ...authentic information Air purging and leakage test 1 Connect charging hose of mani fold valve to charge end of low pressure valve both high low pressure valves must be tightly shut Manifold 2 Connect...

Страница 28: ...secure It may cause electrical leakage earth connection It may cause electric malfunction Is the power cord specified or damage the part Is the inlet and outlet been covered It may cause insufficient...

Страница 29: ...r before cleaning and reinstall it after cleaning according to the ins tallation instruction Pay special attention to that silver ion filter can t be cleaned with water while active carbon photocataly...

Страница 30: ...W 15 30 42000 Btu h 12306 W 12000 Btu h 3516 W 30 20 48000 Btu h 14064 W 18000 Btu h 5274 W 30 25 4 The calculation method of additional refrigerant oil and refrigerant charging amount after prolongin...

Страница 31: ...mm Indoor unit throttle Outdoor unit throttle Gas pipe Cooling only cooling and heating Cooling only g m g m 6 9 5 or 12 20 15 20 6 or 9 5 16 or 19 50 15 50 12 19 or 22 2 100 30 120 16 25 4 or 31 8 17...

Отзывы: