background image

Installation and Maintenance

Service Manual

1. Select  the  installation  location  according  to  the  require-
ment  of  this  manual.(See  the  requirements  in  installation
part)
2. Handle  unit  transportation  with  care;  the  unit  should  not
be carried by only one person if it is more than 20kg.

 :KHQLQVWDOOLQJWKHLQGRRUXQLWDQGRXWGRRUXQLWDVXI¿

-

FLHQW¿[LQJEROWPXVWEHLQVWDOOHGPDNHVXUHWKHLQVWDOODWLRQ

VXSSRUWLV¿UP

4. Ware safety belt if the height of working is above 2m.
5. Use equipped components or appointed components dur-
ing installation.

 0DNHVXUHQRIRUHLJQREMHFWVDUHOHIWLQWKHXQLWDIWHU¿Q

-

ishing installation.

Electrical Safety Precautions:

Notes for Installation and Maintenance

Safety Precautions: 
Important!

Please read the safety precautions carefully before 
installation and maintenance.
The  following  contents  are  very  important  for  installation 
and maintenance.

Please follow the instructions below.

Ɣ7KHLQVWDOODWLRQRUPDLQWHQDQFHPXVWDFFRUGZLWKWKH

instructions.

Ɣ&RPSO\ZLWKDOOQDWLRQDOHOHFWULFDOFRGHVDQGORFDO

electrical codes.

Ɣ3D\DWWHQWLRQWRWKHZDUQLQJVDQGFDXWLRQVLQWKLV

manual.

Ɣ$OOLQVWDOODWLRQDQGPDLQWHQDQFHVKDOOEHSHUIRUPHGE\

GLVWULEXWRURUTXDOL¿HGSHUVRQ

Ɣ$OOHOHFWULFZRUNPXVWEHSHUIRUPHGE\DOLFHQVHG

technician according to local regulations and the 
instructions given in this manual.

Ɣ%HFDXWLRQGXULQJLQVWDOODWLRQDQGPDLQWHQDQFH3URKLELW

incorrect operation to prevent electric shock, casualty and 
other accidents.

1. Cut  off  the  power  supply  of  air  conditioner  before
checking and maintenance.
2. The  air  condition  must  apply  specialized  circuit  and
prohibit share the same circuit with other appliances.
3. The  air  conditioner  should  be  installed  in  suitable
location and ensure the power plug is touchable.
4. Make  sure  each  wiring  terminal  is  connected  firmly
during installation and maintenance.
5. Have  the  unit  adequately  grounded.  The  grounding
wire can’t be used for other purposes.
6. Must apply protective accessories such as protective
boards, cable-cross loop and wire clip.
7. The  live  wire,  neutral  wire  and  grounding  wire  of
power  supply  must  be  corresponding  to  the  live  wire,
neutral wire and grounding wire of the air conditioner.
8. The power cord and power connection wires can’t be
pressed by hard objects.
9. If power cord or connection wire is broken, it must be

UHSODFHGE\DTXDOL¿HGSHUVRQ

 $YRLGFRQWDFWEHWZHHQUHIULJHUDQWDQG¿UHDVLWJHQHUDWHV

poisonous  gas;  Prohibit  prolong  the  connection  pipe  by 
welding.

 $SSO\VSHFL¿HGUHIULJHUDQWRQO\1HYHUKDYHLWPL[HGZLWK

any other refrigerant. Never have air remain in the refrigerant 
line as it may lead to rupture or other hazards.
3 . M a k e  s u r e  n o  r e f r i g e r a n t  g a s  i s  l e a k i n g  o u t  w h e n
installation is completed.
4. If  there  is  refrigerant  leakage,  please  take  sufficient
measure to minimize the density of refrigerant.
5. Never  touch  the  refrigerant  piping  or  compressor  without
wearing glove to avoid scald or frostbite.

Warnings

Refrigerant Safety Precautions:

,PSURSHULQVWDOODWLRQPD\OHDGWR¿UHKD]DUGH[SORVLRQ

electric shock or injury.

Installation Safety Precautions:

Part

ė

: Installation and Maintenance 

10. If  the  power  cord  or  connection  wire  is  not  long  enough,
please  get  the  specialized  power  cord  or  connection  wire
from the manufacture or distributor. Prohibit prolong the wire
by yourself.
11. For  the  air  conditioner  without  plug,  an  air  switch  must
be  installed  in  the  circuit.  The  air  switch  should  be  all-pole
parting and the contact parting distance should be more than
3m.
12. Make sure all wires and pipes are connected properly and
the valves are opened before energizing.
13. Check if there is electric leakage on the unit body. If yes,
please eliminate the electric leakage.

 5HSODFHWKHIXVHZLWKDQHZRQHRIWKHVDPHVSHFL¿FDWLRQ

if  it  is  burnt  down;  don’t  replace  it  with  a  cooper  wire  or 
conducting wire.
15. If  the  unit  is  to  be  installed  in  a  humid  place,  the  circuit
breaker must be installed.

Содержание DS-9KIDB

Страница 1: ...Service Manual Models ASD9U2I DN ASD912UI DN...

Страница 2: ...5U1 Throttling Method Electron expansion valve Cooling Operation Ambient Temperature Range O C 18 43 Heating Operation Ambient Temperature Range O C 15 24 Condenser Material Aluminum Fin copper Tube C...

Страница 3: ...Additional Gas Connection Pipe Length m 10 10 Connection Pipe Gas Additional Charge g m 20 20 Outer Diameter of Liquid Pipe GREE Allocation Metric mm Outer Diameter of Gas Pipe GREE Allocation Metric...

Страница 4: ...6 m3 K 550 500 430 300 550 480 410 290 HKXPLGLI LQJ 9ROXPH K 0 8 1 4 Indoor Unit Model of Indoor Unit 6 6 3URGXFW RGH RI QGRRU 8QLW DQ 7 SH URVV RZ URVV RZ LDPHWHU HQJWK mm DQ 0RWRU RROLQJ 6SHHG 6 0...

Страница 5: ...Technical Information Service Manual Outline Dimension Diagram Indoor Unit Unit mm Models W H D W1 W2 W3 09 12K 773 250 185 131 462 180 D H W 75 35 55 W3 W2 W1 55 35 75...

Страница 6: ...anual 3 Outline Dimension Diagram 892 341 396 963 560 700 368 Unit mm 12 Technical Information Service Manual 3 Outline Dimension Diagram 892 341 396 963 560 700 368 Unit mm 12 Technical Information 8...

Страница 7: ...ease refer to the actual models This is a general use remote controller it could be used for the air conditioners with multifunction For some function which the model doesn t have if press the corresp...

Страница 8: ...m AUTO COOL DRY FAN and HEAT as the following AUTO COOL DRY FAN HEAT Note Only for models with heating function This button is used for setting Fan Speed in the sequence that goes from AUTO to then ba...

Страница 9: ...d buttons simultaneously 3s to lock or unlock the keypad If the remote pressing any button blinks three times controller is locked is displayed In this case Combination of and buttons About lock About...

Страница 10: ...me models Replacement of batteries in remote controller Emergency operation If remote controller is lost or damaged please use auxiliary button to turn on or turn off the air conditioner When the air...

Страница 11: ...t adequately grounded The grounding wire can t be used for other purposes 6 Must apply protective accessories such as protective boards cable cross loop and wire clip 7 The live wire neutral wire and...

Страница 12: ...tape 4 Electroprobe 7 Electronic leakage detector 10 Pipe pliers pipe cutter 2 Screw driver 5 Universal meter 8 Vacuum pump 11 Pipe expander pipe bender 3 Impact drill drill head electric drill 6 Tor...

Страница 13: ...e the bound pipes pass through the wall hole and then connect outdoor unit Neaten the pipes Vacuum pumping and leakage detection Check after installation and test operation Finish installation Note th...

Страница 14: ...o the wall At least 250cm At least 15cm At least 300cm Space to the obstruction Space to the ceiling Space to the obstruction At least 15cm At least 15cm Space to the wall Space to the wall At least 2...

Страница 15: ...LW SOHDVH QRWH WKH IROORZLQJ WDEOH LU VZLWFK VKRXOG EH LQFOXGHG PDJQHW EXFNOH DQG KHDWLQJ EXFNOH IXQFWLRQ LW FDQ SURWHFW WKH FLUFXLW VKRUW DQG RYHUORDG DXWLRQ SOHDVH GR QRW XVH WKH IXVH RQO IRU SURWHF...

Страница 16: ...H SRVLWLRQ RI SLSLQJ KROH VKRXOG EH D OLWWOH ORZHU WKDQ WKH ZDOO PRXQWHG IUDPH V VKRZ LQ LJ 5 Connect the Pipe of Indoor Unit LP WKH SLSH MRLQW DW WKH FRUUHVSRQGLQJ EHOOPRXWK V VKRZ LQ LJ 3UHWLJKWHQLQ...

Страница 17: ...QJ FRYHU DQG WKHQ WDNH GRZQ WKH FRYHU V VKRZ LQ LJ 8 Bind up Pipe LQG XS WKH FRQQHFWLRQ SLSH SRZHU FRUG DQG GUDLQ KRVH ZLWK WKH EDQG V VKRZ LQ LJ 5HVHUYH D FHUWDLQ OHQJWK RI GUDLQ KRVH DQG SRZHU FRUG...

Страница 18: ...apacity please note the following table Air switch should be included magnet buckle and heating buckle function it can protect the circuit short and overload Caution please do not use the fuse only fo...

Страница 19: ...d 3 way valves 2 Unscrew and remove the cap from the service valve 3 Connect the vacuum pump hose to the service valve 4 Operate the vacuum pump for 10 15 minutes until an absolute vacuum of 10 mm Hg...

Страница 20: ...NLQJ XS DQG PRYLQJ WKH XQLWV RX PXVW EH JXLGHGE WUDLQHG DQG TXDOL HG SHUVRQ Ensure that the recommende dspace is left around the appliance 30cm Space to the cover or above 30cm 50cm Air inlet side or...

Страница 21: ......

Отзывы: