To ensure safety, please be mindful of the following precautions. 

Warning

When installing or relocating the unit, be sure to keep the refrigerant 

circuit free from air or substances other than the specified refrigerant.

Any presence of air or other foreign substance in the refrigerant circuit will cause 

system pressure rise or compressor rupture, resulting in injury.

When installing or moving this unit, do not charge the refrigerant which 

is not comply with that on the nameplate or unqualified refrigerant.

Otherwise, it may cause abnormal operation, wrong action, mechanical 

malfunction or even series safety accident.

When refrigerant needs to be recovered during relocating or repairing the 

unit, be sure that the unit is running in cooling mode.Then, fully close the 

valve at high pressure side (liquid valve).About 30-40 seconds later, fully 

close the valve at low pressure side (gas valve), immediately stop the unit 

and disconnect power. Please note that the time for refrigerant recovery 

should  not exceed 1 minute. 

If refrigerant recovery takes too much time, air may be sucked in and cause 

pressure rise or compressor rupture, resulting in injury. 

During refrigerant recovery, make sure that liquid valve and gas valve are 

fully closed and power is disconnected before detaching the connection pipe. 

If compressor starts running when stop valve is open and connection pipe is not 

yet connected, air will be sucked in and cause pressure rise or compressor 

rupture, resulting in injury.

When installing the unit, make sure that connection pipe is securely 

connected before the compressor starts running.

If compressor starts running when stop valve is open and connection pipe is not 

yet connected, air will be sucked in and cause pressure rise or compressor 

rupture, resulting in injury.

Prohibit installing the unit at the place where there may be leaked corrosive 

gas or flammable gas.

If there leaked gas around the unit, it may cause explosion and other accidents. 

Do not use extension cords for electrical connections. If the electric wire 

is not long enough, please contact a local service center authorized  

and ask for a proper electric wire.

Poor connections may lead to electric shock or fire.

Use the specified types of wires for electrical connections between the 

indoor and outdoor units. Firmly clamp the wires so that their terminals 

receive no external stresses.

Electric wires with insufficient capacity, wrong wire connections and insecure 

wire terminals may cause electric shock or fire.

Safety precautions for installing and relocating the unit

Содержание DOS-9UIDA

Страница 1: ...for choosing our product For proper operation please read and keep this manual carefully If you have lost the Owner s Manual please contact the local agent or visit sat eurofredgroup com Split Air Co...

Страница 2: ...26 8 26 8 26 8...

Страница 3: ...To return your used device please use the return and collection systems or contact the retailer where the product was purchased They can take this product for envi ronmental safe recycling This appli...

Страница 4: ...t if not avoided could result in death or serious injury Indicates a hazardous situation that if not avoided may result in minor or moderate injury Indicates important but not hazard related informati...

Страница 5: ...pliance Cleaning and user maintenance shall not be made by children without supervision years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowl...

Страница 6: ...amage Precautions WARNING conditioner and disconnect power immediately and then If the air conditioner operates under abnormal conditions it may cause malfunction electric shock or fire hazard Do not...

Страница 7: ...les before using the air conditioner An all pole disconnection switch having a contact separation Must follow the electric safety regulations when installing the unit grounding wire of power socket Pr...

Страница 8: ...nnected by a professional national wiring regulations requirement of NEC and CEC by authorized personnel only Precautions WARNING wire which can t be used for other purposes The grounding resistance s...

Страница 9: ...he line For the air conditioner without plug an circuit break far away from animals or plants If it is unavoidable please add the fence for safety purpose Select a location which is out of reach for c...

Страница 10: ...6 Outdoor Unit air inlet air outlet Connection wire Parts name Indoor Unit NOTICE Actual product may be different from above graphics please refer to actual products...

Страница 11: ...ension diagram Drainage pipe At least 50cm At least 50cm At least 30cm At least 200cm Space to the obstruction Space to the obstruction Space to the obstruction Space to the obstruction At least 30cm...

Страница 12: ...make sure that liquid valve and gas valve are fully closed and power is disconnected before detaching the connection pipe If compressor starts running when stop valve is open and connection pipe is n...

Страница 13: ...unit 4 Make sure that the installation follows the requirement of installation dimension diagram 5 Select a location which is out of reach for children and far away from animals or plants If it is una...

Страница 14: ...n accordance with national wiring regulations 10 Installation must be performed in accordance with the requirement of NEC and CEC by authorized personnel only grounding with specialized grounding devi...

Страница 15: ...For the unit with cooling capacity of 2300W 5000W 6 expansion screws are needed for the unit with cooling capacity of 6000W 8000W 8 expansion screws are needed for the unit with cooling capacity of 10...

Страница 16: ...handle screw gas pipe liquid pipe liquid valve gas valve union nut pipe joint Hex nut diameter Tightening torque N m 6 9 52 12 16 19 30 40 45 55 60 65 70 75 15 20 1 Remove the wire clip connect the po...

Страница 17: ...than the wall hole you must set a U shaped curve in the pipe before pipe goes into the room in order to prevent rain from getting into the room Installation of outdoor unit U shaped curve wall drain...

Страница 18: ...ure decreases there may be leakage 5 Remove the piezometer open the valve core of liquid valve and gas valve completely with inner hexagon spanner 6 Tighten the screw caps of valves and refrigerant ch...

Страница 19: ...r damaging the parts Is there any obstruction in the air inlet and outlet heating capacity The dust and sundries caused during installation are removed It may cause malfunction or damaging the parts T...

Страница 20: ...requirement as shown in the table The additional refrigerant charging amount per meter is different according to the diameter of liquid pipe See the following sheet Additional refrigerant charging amo...

Страница 21: ...4a Diameter of connection pipe Liquid pipe mm Gas pipe mm 6 6 or 9 52 12 16 19 22 2 9 52 or 12 16 or 19 19 or 22 2 25 4 or 31 8 _ _ Cooling only g m Cooling and heating g m 15 15 30 60 250 250 350 350...

Страница 22: ...n suitable insulating pipe D Put on the union nut Remove the union nut on the indoor connection pipe and outdoor valve install the union nut on the pipe union pipe pipe E Expand the port Expand the po...

Страница 23: ......

Страница 24: ...66129924119...

Отзывы: