background image

INGLES

- 36 -

The dehumidification capacity is the value obtained after the dehumidifier was continuously run in the
room temperature of 30ºC with the relative humidity 80%.

The amount of dehumidification is the amount per day (24 hours.)

If specifications are changed without notice for further improvement, they are data on nameplate of the
unit.

The work temperature is in the range 2ºC to 38ºC. If the room temperature is beyond the range, the unit
can not operate normally.

Structure and Principle

Powerful dehumidifying capability 

● 

Taking advantage of refrigeration principle,
the dehumidifier powerfully removes partial
moisture from air to drop the humidity of the
room and keep indoor air dry and comforta-
ble.

Quiet operation 

When the dehumidifier operates in QUIET
mode, the value of its noise is so low and
makes your room quiet.

Using refrigerant for protecting environment

● 

The dehumidifier uses the no CFC refrigerant
for protecting environment to reduce to pollu-
te environment.

Excellent drying laundry function

● 

The dehumidifier dries laundry quickly. This

can prevent laundry and furniture from beco-
ming damp and musty in a rainy season.

Drainage tank with a large capacity

The drainage tank capacity is large to 6 liters;
this will reduce the times of your discarding
water.

Saving energy

● 

The power consumption is low.

SPECIFICATIONS 

● 

Features

Structure and Principle

Power Supply

220~230V, 50Hz

Dehumidifying Capacity

12 L/day

20 L/day

Power Consumption

190W

360W

Drainage Tank Capacity

6,0 L (automatic stop at about 5.5L) 

Weight

12,5 kg

14 kg

Dimension (height x width x depth))

545 mm x 380 mm x 261,5 mm

Model

ADD12 

ADD20   

● 

Specifications

Содержание ADD12

Страница 1: ...37 Structure of dehumidifier 37 OPERATION Operation panel 38 Switch function 39 Operation steps 39 40 Draining the water 40 41 MAINTENANCE Caring for the dehumidifier 42 Storing the dehumidifier 42 N...

Страница 2: ...tion When the dehumidifier operates in QUIET mode the value of its noise is so low and makes your room quiet Using refrigerant for protecting environment The dehumidifier uses the no CFC refrigerant f...

Страница 3: ...a drainage tank The dehumidified air is re heated by a heating unit and discharged Steps and are repeated to remove humidity from the room After the air passes through the re heating unit its tempera...

Страница 4: ...the tank is positioned properly 2 Power indicator lamp It will light when the unit is plugged in 3 mode indicator lamp When lamp or lamp or lamp is lighted it respectively indicates that operation is...

Страница 5: ...ter the operation is started the default operation mode is the continuous mode the operation is continuous in the continuous mode until the unit is stopped or automatically stopped for the drainage ta...

Страница 6: ...damage the tank and cause water to leak Draining the water 3 Switch the operation mode Press the 1 0 switch the unit operates in CONTINOUS mode automatically DEHUMIDIFY mode Press switch until the lam...

Страница 7: ...m the water in the drainage tank can be continuously drained out of the continuous port of the unit When setting up the equipment for continuous drainage always stop operation first and unplug the pow...

Страница 8: ...the air filter is very dirty wash it with warm water and a neutral cleaning solvent and dry it thoroughly 3 Attach the air filter Insert the lower tabs of the air filter into the main unit and press...

Страница 9: ...e stored 10 Install drain piping in a downhill grade to make sure that condensed water can be drained conti nuously 11 If the supply cord is damaged it must be replaced by the manufacture or its servi...

Страница 10: ...After the above condition has occurred and corresponding step is used but the breakdown can not be removed or other breakdown occurs please contact the authorized service centers The following symptom...

Страница 11: ...does not indicate a problem The unit only can run in laundry mode and it is ineffective to press mode switch When the temperature of the room is above 35 C or below 15 C the protection device is actu...

Страница 12: ......

Отзывы: