In factory configuration, the movement
detector is configured in deterrence (for the
reactions of the system see the control panel
installation guide). It is possible to modify the
level of alarm using the following sequence
of parameter setting:
Sequence of
parameter setting
Configuration example: setting the
detector for an alarm level when a prealarm
is triggered: Parameter n° 5, Parameter value
2.
?
?
4. Configuration
sequence
about
5 sec.
about 10 sec.
about
2 sec.
about 10 sec.
To start the
sequence
press and
hold the
button until the
LED indicator
lamp goes out
Press 5 times
depending
on the required
parameter
number
Press and
hold until the
LED
indicator
lamp briefly
goes out
Press 1 to 4
times depending
on the required
parameter value
To end the
sequence press
and hold the
button until the
LED indicator
lamp goes out
LED indicator
lamp lit =
correct
configuration
{
{
Start
Press 5 times
to select
the alarm
level
Press
once to
accept
selection
Press 2 times
to select
the preal
level
End
5
2
about
2 sec.
Indicator lamp
for
programming it
Indicator lamp
for programming
not lit
Parameter n°
Alarm level
Parameter value
5
Intrusion
1
Prealarm
2
Deterrence
3 (factory setting)
Warning
4 (the feature is available usingn eclosntrol pa
with 2.0.0 version software or later)