connect up to 5 leads (see the Installation Instructions for the 

MTR kit at www.dairyland.com). Continue to leave the ground-

ing jumper connected.

13. Since the isolation switch was previously placed in the OFF 

position (i.e., switch open) in step 3, the lead to be reconnected 

to the decoupler negative terminal in this step is not connected 

to the pipeline so it can be installed by hand. Take the lead 

that was connected to other isolation switch stud near the bot-

tom end of the pedestal cover, bend it over the top edge of the 

pedestal base and form it so the terminal on this lead comes 

straight up to the decoupler terminal as illustrated in the left 

photo below. Apply Tef-Gel to the terminal pad that will be in 

contact with the negative decoupler terminal. Use the hardware 

that was removed from this decoupler terminal in an earlier step 

and bolt these connections together tightening securely. After 

this connection is completed, open the cover on the isolation 

switch enclosure, pull out the switch mechanism, rotate 180° 

and reinsert fully. The switch is now ON with the decoupler con-

nected to the pipeline.

14. Remove the grounding jumper because the pipeline is now 

grounded through the decoupler and switch. As a precaution, 

insulate the bolted splice joint done in step 12 with a materi-

al of the users choice to prevent this pipeline lead from being 

touched whenever the pedestal cover is removed.

16. The pedestal cover can now be reinstalled over the pedestal 

base as illustrated and the pedestal cover locked.

                

      

17. If the decoupler is to be left connected to the pipeline, no 

further action is required because the pull out switch is already 

ON (i.e., decoupler connected). If the decoupler is to be left 

disconnected, then return the switch to its OFF position. Confirm 

that the isolation switch is left in the desired position, then close 

the isolation switch enclosure cover and lock. This completes 

the installation instructions.

The isolation switch operating instructions are found inside 

the enclosure cover. Read and follow these instructions. Cer-

tain steps recommend abruptly pulling out and reinserting the 

switch mechanism and the reason for this is to minimize arcing 

time on the switch contacts.