[10]
Rev 4/15/14
Dairy Tech, Inc.
Service Manual:
DT10G, DT30G &DT60G
Connecting the Milk Spigot
The Platinum Units come supplied with the highest quality
304SS butterfly drain valve. These are installed on the front
flange of the tank drain much the same as connections are made
to a bulk tank flange using the clamps provided. Please see the
diagram below. Make certain to include the gasket between
each fitting. These parts can then be easily removed for
thorough cleaning in a sink. See next image.
Choosing and Preparing a Location
Criteria for Selecting a Location
a)
Choose an indoor spot that will be protected from the
elements. Extreme heat will allow milk spoilage and
freezing temperatures will damage the unit.
b)
Cold water is required to be connected to the unit for
water cooling the milk or colostrum, and a nearby hot
water source is necessary for proper cleaning.
c)
Floor drains will allow for proper cleaning and
rinsing of the product as well as to clean up milk
spills.
d)
Power requirements are 240vac 30 or 50 amp circuit
breaker rated for use as branch circuit protection.
DT10G & 30G-EU models for European installations
that require 240vac single phase or 480vac 3 Phase
connections contain an internal step-down
transformer to provide 120vac for control power in
models where necessary.
e)
Floor space requirements are approx 1 yd² (1M²)
f)
Avoiding extremely drafty areas will improve heating
efficiency of the unit.
g)
Always have 2 people lift and carry the unit grasping
with both hands on the sides of the unit. The supports
of the legs can be used for lifting. Never attempt to
move the unit while it is full of milk or water.
Connecting the Hoses for
Water-Cooling
WATER-Cooled Units: A 6’ black supply hose is supplied with
the machine. This hose with factory ends supplies all the cold
water to cool the product when pasteurization is finished. It can
connect to any normal domestic pressure cold water source
including a hose but it MUST BE ON AT ALL TIMES
DURING OPERATION. Using the supplied hose, attach one
end where indicated on the back of the unit, with the other end
going to a regular hose bib supply. Pressure reduction is
provided by the orifice of the solenoid valve. A relief valve is
incorporated into the design of the DT30G and DT10G with a
port coming out of the bottom of the unit toward the right rear.
The DT60G Model contains dual pressure ports. Should the
drain line be raised too high or blocked, pressure will relieve
itself by opening this valve which will spill water onto the
floor. This protects the metal milk tanks from implosion in high
pressure situations. Take care to avoid situations where any
back pressure exists on the drain line. This will void the
warranty.
Содержание DT10G
Страница 2: ...2 Rev 4 15 14 Dairy Tech Inc Service Manual DT10G DT30G DT60G...
Страница 31: ...31 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz USA Domestic...
Страница 32: ...32 Rev 4 15 14 Schematic for Model DT10 30 60G 200 to 240VAC 1P 50 60Hz England Japan...
Страница 33: ...33 Rev 4 15 14 Schematic for Model DT10 30 60G 400VAC 3P Europe...
Страница 34: ...34 Rev 4 15 14 NOTES...
Страница 38: ...38 Rev 4 15 14...