background image

Lumination

®

 (Tetra

® 

PowerGrid - Series)                     

                

Installation Guide

3

Install Modules

2” (51 mm)

from edge

2.77” (70 mm)

between columns

Lay modules into the application at least 2 inches (51 mm) 

from the edges.
Fasten down each module with at least one screw

in the center hole or two opposing sides.

1

Start another row with 2.77-inch (70 mm) spacing between 

the module strings.
Continue this process until the entire application is

populated with modules.

2

Using the diagram below as an estimation guide, begin cutting strings of modules to create 8-inch (203 mm) tall

rows and 12-inch (305 mm) wide columns.
Modules should be 2 inches (51 mm) from the edge of the application with 2.77 inches (70 mm) between 

each column.

2

Typical layout

12” (305 mm)

wide columns

2” (51 mm)

from edge

2” (51 mm)

from edge

8” (203 mm)

tall 

rows

2.77” (70 mm)

between

 columns

2” (51 mm)

from edge

2.77” (70 mm)

between columns