5
Push fixture through the hole in the ceiling. This will
engage the protruding arms, thus, releasing the springs.
The springs will draw the fixture up into the ceiling and
hold it tightly in place.
Connect AC line to existing junction box. Connect conduit fitting to the existing junction box. Connect the black,
white, and green/yellow wires of the input leads to the black, white and green AC line wires using UL Listed twist-
on wire connectors and close the junction box (see wiring diagram).
Connect the two quick connectors and reassemble
the connector box.
Load springs into an upright position by twisting
the springs upware. Carefully insert the fixture into
the frame hole. Ensure fixture is secure.