DTP10-D hardware user
’s manual
DAINCUBE Corp.
15 / 35
(1) Enabling switch
This product is equipped with 3 stage Enabling switch as standard. As shown in the above drawing, the
enabling switch is on the back of the pendant. This switch is called the alias dead-man switch.
0
1
0
C1
NO1
NC1
NC2
C2
NO2
SWEN1+
SWEN1-
SWEN2-
SWEN2+
External
Enabling Switch
[Figure 6.6] Enabling switch
Action
Position
Picture
Symbol
Not pressed
Null
SWEN2-
SWEN2+
SWEN1-
SWEN1+
Pressed
Enabling
SWEN2-
SWEN2+
SWEN1-
SWEN1+
Pressed strong
Panic
SWEN2-
SWEN2+
SWEN1-
SWEN1+
[T
able
6-2]
Enabling switch operation