22
TM-RHR-1214-A
9.2 Plumbling. (Refer to the Tank Installation Diagram 9.21)
Plumbing must be done by a qualified person in accordance with the local water supply
regulations for main pressure storage tanks. However we recommend:
•
Flush the water system thoroughly before fitting water tank and tempering valve. If
the water supply is of poor which caused the tampering valve to be block, fit an
additional filter or the strainer to the water inlet system.
•
Drain pipe must be connected to the pressure and temperature relief valve. The
open end of the drain pipe must be connected to drain so that any discharge is visible
but will not cause damage or scalding.
•
Installation of pressure-reducing valve may be required if the maximum supply pressure
can exceed the limit marked on the product label.
•
Fitting an isolating and non return valve.
•
Use high quality insulation on the hot water lines to minimize heat loss.
• Strictly no PVC is allowed for both cold water inlet and hot water outlet piping.
OUTLET
(red ring)
INLET
(Blue ring)
Temperature & Pressure Relief Valve/
Injap Pelepas Suhu & Tekanan
Strictly no PVC, ABS, UPVC Allowed
Содержание WinterSpa RHR-B Series
Страница 1: ...Heat Reclaim TM RHR 1214 A TECHNICAL MANUAL...
Страница 11: ...9 TM RHR 1214 A 5 Refrigerant Cycle Diagram...
Страница 14: ...12 TM RHR 1214 A 7 Wiring Diagram Indoor Unit Outdoor Unit Model RHR10CV1...
Страница 15: ...13 TM RHR 1214 A Model RHR15CV1 Indoor Unit Outdoor Unit...
Страница 16: ...14 TM RHR 1214 A Model RHR20CV1 Indoor Unit Outdoor Unit...
Страница 17: ...15 TM RHR 1214 A Model RHR25CV1 Indoor Unit Outdoor Unit...
Страница 18: ...16 TM RHR 1214 A Model RHR30BV1 Indoor Unit Outdoor Unit...
Страница 25: ...23 TM RHR 1214 A Tank Installation Diagram 9 22...