Operation manual

21

HXHD125A7V1B

VRVIII system indoor unit

4PW62585-1 – 11.2010

6.

M

AINTENANCE

6.1.

Maintenance activities

In order to ensure optimal operation of the unit, a number of checks
and inspections should be carried out on the unit at regular intervals,
preferably yearly. This maintenance shall be carried out by the
installer or service agent. Refer to the installation manual for more
details.

The only maintenance which may be required by the operator is:

keeping the remote controller clean by means of a soft damp
cloth,

checking if the water pressure indicated on the manometer is
above 1 bar.

6.2.

Important information regarding the refrigerant 
used

This product contains fluorinated greenhouse gases covered by the
Kyoto Protocol.

Refrigerant type:

R134a

GWP

(1)

 value:

1300

Refrigerant type:

R410A

GWP

(1)

 value:

1975

(1)

 GWP = global warming potential

Periodical inspections for refrigerant leaks may be required
depending on the applicable legislation. Please contat your installer
for more information.

7.

T

ROUBLESHOOTING

This section provides useful information for diagnosing and correcting
certain problems which may occur with the unit.

WARNING

If the supply cord is damaged, it must be replaced by the
manufacturer, its agent or similar qualified persons in order
to avoid hazards.

WARNING

During longer periods of standstill, e.g. during summer with
a heating only application, it is very important NOT TO
SWITCH OFF THE POWER SUPPLY towards the unit.

Switching off the power supply stops the automatic
repetitive movement of the pump in order to prevent it from
getting jammed.

P

OSSIBLE

 

CAUSES

C

ORRECTIVE

 

ACTIONS

No readings on the remote controller 
(blank display)

• Check if the mains power is still 

connected to your installation.

• The benefit kWh rate power 

supply is active (see installation 
manual).

One of the error codes appears

Consult your local dealer.
Refer to the installation manual for a 
detailed list of error codes.

The schedule timer does work but 
the programmed actions are 
executed at the wrong time
(e.g. 1 hour too late or too early)

Check if the clock and the day of the 
week are set correctly, correct if 
necessary.

The domestic hot water schedule 
timer is programmed but does not 
work.

In case the 

pr

 icon is not displayed, 

push the 

pr

 button to enable the 

schedule timer.

Capacity shortage

Consult your local dealer.

Содержание VRVIII

Страница 1: ...VRVIII system indoor unit OPERATION MANUAL HXHD125A7V1B system indoor unit...

Страница 2: ...ppliance by a person responsible for their safety Children shall be supervised to ensure that they do not play with the appliance 1 DEFINITIONS 1 1 Meaning of warnings and symbols Warnings in this man...

Страница 3: ...Scope of this manual This manual describes how to start up and switch off the unit set parameters and con gure the schedule timer by means of the controller maintain the unit and solve operational pr...

Страница 4: ...up and the unit will start For further details and advised settings see 5 3 Space heating operation h h h h on page 6 Domestic water heating only if domestic hot water tank option is installed Automat...

Страница 5: ...PLAY 9 The display shows the current temperature of the installation either leaving water set point temperature or actual room temperature When changing the room temperature set point the set point wi...

Страница 6: ...it outdoor ambient temperature actual room temperature and domestic hot water temperature and in schedule timer programming mode 29 LEAVING WATER TEMPERATURE ADJUST BUTTONS bi and bj These buttons are...

Страница 7: ...mperature The setback function can for instance be activated during the night because the temperature demands during night and day are not the same The setback function is con gured through eld settin...

Страница 8: ...s the ba button 1 time to select weather dependent set point operation or 2 times when the remote controller room thermostat function is used Icon a appears on the display as well as the shift value T...

Страница 9: ...when space heating requirements are lower until the storage temperature set point is reached The heated water is stored in the domestic hot water tank at a higher temperature so it can ful l the dome...

Страница 10: ...too so that storage temperature set point can be set lower in order to keep the overall equivalent hot water amount the same during the whole year Therefor it is recommended to use this function b 04...

Страница 11: ...to ON 5 5 Other operation modes Start up operation d During start up the d icon displays indicating that the heat pump is starting up and is not working in a steady state condition Defrost operation d...

Страница 12: ...allation is controlled by the schedule timer The actions programmed in the schedule timer will be executed automatically The schedule timer is enabled p icon displayed or disabled p icon not displayed...

Страница 13: ...will remain active until the next programmed command 19 00 occurs So in order to know the actual setting one should consult the last programmed command It is clear that the last programmed command ma...

Страница 14: ...out the form at the very end of this manual This form can help you de ne the required actions for each day Take your time to enter all data accurately Try to program the actions in a chronological wa...

Страница 15: ...i and bj buttons to set the room temperature 11 Use the ba button to select x to switch heating and the remote controller off a to select automatic temperature calculation for leaving water temperatur...

Страница 16: ...tton to select the action number you would like to program or to modify 8 Use the pi and pj buttons to set the correct action time 9 Use the ba button to select or deselect x as action 10 Repeat steps...

Страница 17: ...fy 7 Use the pi and pj buttons to set the correct action time 8 Use the ba button to select or deselect x as action 9 Repeat steps 6 to 8 to program the other actions of the selected mode When all act...

Страница 18: ...return to step 2 by pressing the pr button Deleting one or more programmed actions Deleting one or more programmed actions is done at the same time as storing the programmed actions When all actions...

Страница 19: ...t selected eld setting code is indicated 2 with the set value displayed to the right 1 2 Press the bi button to select the appropriate eld setting rst code 3 Press the bj button to select the appropri...

Страница 20: ...mperature Lo_Ti 70 25 80 1 C 03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1 01 Disinfection operation day selection Fri M...

Страница 21: ...icable Do not change the default value 20 03 Not applicable Do not change the default value 5 04 Not applicable Do not change the default value 0 d Domestic water heating retention times 00 Installati...

Страница 22: ...for diagnosing and correcting certain problems which may occur with the unit WARNING If the supply cord is damaged it must be replaced by the manufacturer its agent or similar quali ed persons in orde...

Страница 23: ......

Страница 24: ...4PW62585 1 11 2010 Copyright 2011 Daikin...

Отзывы: