background image

 

Operation manual

 

1

 

HXHD1 HXHD200AY1B

 

VRV IV system indoor unit

 

4P513553-1 – 2017.11

 

C

 

ONTENTS

 

Page

 

1.

Definitions.................................................................................. 1

 

1.1.

Meaning of warnings and symbols................................................. 1

1.2.

Meaning of used terms .................................................................. 1

 

2.

General safety precautions........................................................ 2

3.

Introduction................................................................................ 2

 

3.1.

General information........................................................................ 2

3.2.

Scope of this manual ..................................................................... 2

 

4.

Quick start-up of the unit ........................................................... 3

 

Space heating operation ................................................................ 3
Domestic water heating operation.................................................. 3

 

5.

Operation of the unit .................................................................. 4

 

5.1.

Remote controller buttons and icons.............................................. 4

5.2.

Setting the clock............................................................................. 5

5.3.

Space heating operation (

 

).......................................................... 6

Room temperature control ............................................................. 6
Leaving water temperature control................................................. 7

5.4.

Domestic water heating operation (

 

) .......................................... 8

Automatic storage .......................................................................... 8
Manual storage .............................................................................. 9
Reheat ......................................................................................... 10
Disinfection operation................................................................... 10

5.5.

Other operation modes ................................................................ 10
Start up operation (

 

) ........................................................... 10

Defrost operation (

 

) ............................................................ 10

Quiet mode operation (

 

) .......................................................... 10

5.6.

Simultaneous demand of space heating and domestic water 
heating ......................................................................................... 11

5.7.

Temperature read-out mode......................................................... 11

5.8.

Schedule timer operation ............................................................. 11
Space heating .............................................................................. 11
Domestic water heating................................................................ 13
Quiet mode .................................................................................. 13

5.9.

Programming and consulting the schedule timer ......................... 13
Programming space heating ........................................................ 14
Programming domestic water heating.......................................... 15
Programming quiet mode............................................................. 16
Consulting programmed actions .................................................. 17
Tips and tricks .............................................................................. 17

5.10. Operating the remote alarm option .............................................. 17
5.11. Operating the optional remote controller...................................... 17
5.12. Field settings ................................................................................ 18

Procedure .................................................................................... 18

5.13. Field settings table ....................................................................... 19

 

6.

Maintenance ............................................................................ 21

 

6.1.

Maintenance activities.................................................................. 21

6.2.

Important information regarding the refrigerant used................... 21

 

7.

Troubleshooting ....................................................................... 21

 

Thank you for purchasing this unit.

The original instructions are written in English. All other languages
are translations of the original instructions.

This appliance is not intended for use by persons, including children,
with reduced physical, sensory or mental capabilities, or lack of
experience and knowledge, unless they have been given supervision
or instruction concerning use of the appliance by a person
responsible for their safety.
Children shall be supervised to ensure that they do not play with the
appliance.

 

1. D

 

EFINITIONS

 

1.1.

Meaning of warnings and symbols

 

Warnings in this manual are classified according to their severity and
probability of occurrence.

Some types of danger are represented by special symbols:

 

1.2.

Meaning of used terms

 

Installation manual:

 

Instruction manual specified for a certain product or application,
explaining how to install, configure and maintain it.

 

Operation manual:

 

Instruction manual specified for a certain product or application,
explaining how to operate it.

 

Maintenance instructions:

 

Instruction manual specified for a certain product or application,
which explains (if relevant) how to install, configure, operate and/or
maintain the product or application.

 

Dealer:

 

Sales distributor for products as per the subject of this manual.

 

Installer:

 

Technical skilled person who is qualified to install products as per the
subject of this manual.

 

HXHD125AV1B
HXHD200AY1B

 

VRV IV system indoor unit

 

Operation manual

 

CAREFULLY READ THESE INSTRUCTIONS BEFORE
OPERATING THE UNIT. THEY WILL TELL YOU HOW TO
USE THE UNIT PROPERLY. KEEP THIS MANUAL IN A
HANDY PLACE FOR FUTURE REFERENCE.

 

CAUTION

 

 

This unit contains electrical and hot parts.

 

 

Before operating the unit, be sure the installation has
been carried out correctly by an installer.
If you feel unsure about operation, contact your
installer for advice and information.

 

DANGER

 

Indicates an imminently hazardous situation which, if not
avoided, will result in death or serious injury.

 

WARNING

 

Indicates a potentially hazardous situation which, if not
avoided, could result in death or serious injury.

 

CAUTION

 

Indicates a potentially hazardous situation which, if not
avoided, may result in minor or moderate injury. It may also
be used to alert against unsafe practices.

 

NOTICE

 

Indicates situations that may result in equipment or
property-damage accidents only.

 

INFORMATION

 

This symbol identifies useful tips or additional information.

 

Electric current.

 

Danger of burning and scalding.

 

4PEN513553-1_2017_11.book  Page 1  Saturday, January 27, 2018  5:37 PM

Содержание VRV IV HXHD125AV1B

Страница 1: ...OPERATION MANUAL HXHD125AV1B HXHD200AY1B system indoor unit 4PEN513553 1_2017_11 book Page 1 Saturday January 27 2018 5 37 PM...

Страница 2: ...r safety Children shall be supervised to ensure that they do not play with the appliance 1 DEFINITIONS 1 1 Meaning of warnings and symbols Warnings in this manual are classified according to their sev...

Страница 3: ...is manual describes how to start up and switch off the unit set parameters and configure the schedule timer by means of the controller maintain the unit and solve operational problems DANGER ELECTRICA...

Страница 4: ...start For further details and advised settings see 5 3 Space heating operation on page 6 Domestic water heating only if domestic hot water tank option is installed Automatic storage daily water heat...

Страница 5: ...installation either leaving water set point temperature or actual room temperature When changing the room temperature set point the set point will be flashing for 5 seconds and then return to the actu...

Страница 6: ...ient temperature actual room temperature and domestic hot water temperature and in schedule timer programming mode 29 LEAVING WATER TEMPERATURE ADJUST BUTTONS and These buttons are used to adjust the...

Страница 7: ...nce be activated during the night because the temperature demands during night and day are not the same The setback function is configured through field settings Refer to the chapter 5 12 Field settin...

Страница 8: ...select weather dependent set point operation or 2 times when the remote controller room thermostat function is used Icon appears on the display as well as the shift value The shift value is not shown...

Страница 9: ...irements are lower until the storage temperature set point is reached The heated water is stored in the domestic hot water tank at a higher temperature so it can fulfil the domestic hot water requirem...

Страница 10: ...mperature set point can be set lower in order to keep the overall equivalent hot water amount the same during the whole year Therefor it is recommended to use this function b 04 Automatic maximum dome...

Страница 11: ...Other operation modes Start up operation During start up the icon displays indicating that the heat pump is starting up and is not working in a steady state condition Defrost operation In space heatin...

Страница 12: ...ule timer The actions programmed in the schedule timer will be executed automatically The schedule timer is enabled icon displayed or disabled icon not displayed by pressing the button Space heating R...

Страница 13: ...the next programmed command 19 00 occurs So in order to know the actual setting one should consult the last programmed command It is clear that the last programmed command may date from the day before...

Страница 14: ...d of this manual This form can help you define the required actions for each day Take your time to enter all data accurately Try to program the actions in a chronological way start with action 1 for t...

Страница 15: ...temperature 11 Use the button to select to switch heating and the remote controller off to select automatic temperature calculation for leaving water temperature Use the and buttons to set the approp...

Страница 16: ...number you would like to program or to modify 8 Use the and buttons to set the correct action time 9 Use the button to select or deselect as action 10 Repeat steps 7 to 9 to program the other actions...

Страница 17: ...to set the correct action time 8 Use the button to select or deselect as action 9 Repeat steps 6 to 8 to program the other actions of the selected mode When all actions have been programmed make sure...

Страница 18: ...ton Deleting one or more programmed actions Deleting one or more programmed actions is done at the same time as storing the programmed actions When all actions for one day have been programmed make su...

Страница 19: ...etting code is indicated 2 with the set value displayed to the right 1 2 Press the button to select the appropriate field setting first code 3 Press the button to select the appropriate field setting...

Страница 20: ...03 Set point at high ambient temperature Hi_Ti 45 25 80 1 C 4 Disinfection function 00 Status disinfection operation 1 ON 0 1 01 Disinfection operation day selection Fri Mon Sun 02 Disinfection opera...

Страница 21: ...ault value 20 03 Not applicable Do not change the default value 5 04 Not applicable Do not change the default value 0 d Domestic water heating retention times 00 Installation related setting a 10 5 20...

Страница 22: ...orrecting certain problems which may occur with the unit WARNING If the supply cord is damaged it must be replaced by the manufacturer its agent or similar qualified persons in order to avoid hazards...

Страница 23: ...4PEN513553 1_2017_11 book Page 1 Saturday January 27 2018 5 37 PM...

Страница 24: ...4P513553 1 2017 11 Copyright 2017 Daikin 4PEN513553 1_2017_11 book Page 1 Saturday January 27 2018 5 37 PM 4P513553 1 0000000K...

Отзывы: